Manifold with Stainless Steel Plate: S, Model: 51S (EX260), SI Unit: NBN (Negative Common, PNP; PROFIBUS DP; 16 Outputs; M12 Connector), Wiring Type: All Double Wiring, Valve Stations: 08 (8 Stations, All Double Wiring), Port Size: 01 [4(A)/2(B) Port: 1/8; 1(P)/3(EB), 5(EA) Port: 1/4], Thread Type: F (G), Option: P (Trim Plate)
Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: T (w/Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: F (G), Actuation Type: A (N.C.,
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 20, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 01 (1/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Type of Actuation: 1 (2 Position Single), Manifold Type: 60 (Body Ported Plug-in Cassette), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 01 (Body Ported 1/8), Thread: F (G)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8), Thread: F (G)