g 1 0.927= 20L/min 3 420 (1 atm)65R.H. 0 (1 atm) 4 mm PVC 1.14 mm AWG23 0.72 mm -36No.PF-OMO0007CN () a(L/min) b(L/min) PF2A710 A 1 10 PF2A750 B 5 50 PF2A711 C 10 100 PF2A721 D 20 200 PF2A751 E 50 500 -37No.PF-OMO0007CN PF2A710/750 PF2A711/721/751 -38No.PF-OMO0007CN ()ZS-37-A (L )ZS-37-B ZS-29-T -39No.PF-OMO0007CN NPN(1 ) + (15 V) NPN(1 ) + (420 mA) PNP(1 ) + (15 V) PNP(1 )

Operating Pressure Particulate Generation Grade Classifications 1.2 104 Average particle concentration Particles/ft3 Max. operating pressure MPa Grade 4 1.0 103 0.8 Grade 3 102 0.6 101 Grade 2 100 0.4 Grade 1 10-1 0.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 15-17-3 4 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06 Body size 1 2 3 4 M5 standard

400 200 300 100 200 300 400 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH3100-02 SRH3110-02 SRH3100-02 0.5 0.20 0.20 0.4 Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 0 100 200 300 400 0 2 4 6 400 100 200 300 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min SRH4000-03 SRH4010-03 SRH4000-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure

Fix one end and bend the loop gradually at 100 mm/min. Measure 2R when the tube breaks or is crushed.

Cylinder extension speed: 100 mm/s Meter-out needle fully open 100 mm/s Return speed Solenoid valve (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3-port is recommended. Exhaust port (EA) Supply port (P) Exhaust port (EB) Fig.

Possible to use in vacuum to 100 kPa Tubing material Tubing O.D.

V 100 V or less 100 V, 200 V 200 V or less 24 V or less IC circuit Grommet Relay, PLC 12 V Connector 2-wire 24 V IC circuit PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state

2 Rotary Actuator Rack & Pinion Style Series CRA1 Size: 30, 50, 63, 80, 100 How to Order Mounting style Basic style Foot style B L Rotating angle 90 180 Rod end shape 90 180 Double shaft CRA1 B W 30 90 Size 30 CRA1 B S 50 90 Size 50 to 100 Mounting style Air cushion None With air cushion Nil C B L Basic style Foot style Flange style F For part numbers, refer to the tables below.

Applicable stroke table Standard Model Stroke (mm) 100 200 300 400 500 600 700 800 900 1000 Manufacturable stroke range [mm] LEFS16 100 to 400 LEFS25 100 to 600 LEFS32 100 to 800 LEFS40 200 to 1000 Strokes are manufacturable in 1 mm increments. Refer to the manufacturable stroke range. However, strokes other than those shown above are produced as special orders.

V 5 V, 12 V, 24 V, 100 V Heavy-duty cord Reed switch Parallel cord 100 V Heavy-duty cord 3-wire (NPN) 5 V, 12 V IC circuit Solid state switch Grommet 3-wire (PNP) 12 V MDSUA7 Relay, Connector Grommet Connector Grommet Connector Heavy-duty cord 2-wire 24 V MDSUA20 100 V PLC Reed switch 100 V IC circuit 48 V, 100 V 24 V or less Order example: MSUA20 single vane type (connection port side location

Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer

(Full span Full-scale) O PLC DC1224[V] ON-OFF 1 NPN OFF PLC PLC 2 NPN ON PLC PLC ON-OFF ON-OFF NPN PNP 1 NPN OFF ON-OFF PLC DC1224[V] 2 NPN ON R R.D. 1.0005R.D. 1.0005 = 0.05 0.8005R.D. 0.8005 = 0.04 S SUS ON-OFF ON OFF ON-OFF 25[]0 50[]-550[] )3.0[F.S.]25[] 100[kPa] F.S.=100-0=100[kPa] 3.0F.S.=1000.03=3[kPa] 050[] 3[kPa] -10No.PS-OMH0002CN-D () () 25[]ON-OFF )100

Lead wire length (m) Load voltage Auto switch model Indicator light Type Electrical entry Wiring (Output) Pre-wire connector Special function Applicable bore size (mm) Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC 80, 100 20 to 63 3-wire (NPN equivalent) IC circuit 5 V C76 Reed switch Solid state switch Grommet B54 C73 C73C 100 V, 200 V 100 V Yes Yes 12 V Relay, PLC 24 V Connector

0 25 50 75 100 Input signal (%F.S.)

Terms Meaning 100 100BASE-TX Standard LAN transmission line with communication speed of 100 Mbps. A Auto negotiation The function that automatically optimizes the common communication parameters such as speed, duplex mode, and flow control between Ethernet devices. C Counts The MPC controls and reports position internally in Counts.

10 10 11 B C 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2 JC20-8-100 JC20-8-125 JC32-10-100 JC30-10-125 JC25-10-150 JC40-12-125 JC40-12-150 JC40-12-175 JC40-14-150 JC50-16-150 JC63-16-200 JC63-18-150 DA00207 DA00169 DA00141 DA00142 DA00140 DA00145 DA00146 DA00143 DA00148 DA00151 DA00150 DA00153 13 13 17 17 17 19 19 19 22 24 24 27 Spare parts Rod end nut The basic type has one rod

k 250 1 k 600 IP67 -34No.EX-OMN0037CN-A 0V 2 EX600 4 (-)2 (+) 4 3 4 -35No.EX-OMN0037CN-A LED LED OFF OFF 0 1 () () (SI ) -36No.EX-OMN0037CN-A EX600-AMB M12 (5 ) 1 2 (1 /) () DC24 V Class22 A 0.5 A/ 12 bit 010 V15 V05 V 020 mA420 mA 15 V 40 mA 100 k 250 (25 ) 0.05 F.S. (25 ) 0.15 F.S. (25 ) 0.5F.S. 0.6F.S.

First find the ratio of the discharge rate for fresh water when viscosity is 100 mPas from the graph below. It is determined to be 45%. 2. Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 2.7 L/min.

First find the ratio of the discharge rate for fresh water when viscosity is 100 mPas from the 3) Viscosity Characteristics (Flow rate correction for viscous fluids) graph below. It is determined to be 45%. 2. Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 2.7 L/min.

First find the ratio of the discharge rate for fresh water when viscosity is 100 mPas from the graph below. It is determined to be 45%. 2. Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 2.7 L/min.