Handle Note Body 1348102#1 ADC POM e Piston assembly Bonnet 1348104A r POM POM, NBR Valve 1348105 t Brass, NBR Valve spring 1348109 y Stainless steel 1348108 (For 0.85 MPa) Steel wire Adjusting spring u 1348108-1 (For 0.3 MPa) Dimensions Panel cutout dimensions 26 R2.5 SUP OUT SMC K C O P A A L U S H 12 37 54 25 1.6 (Max. thickness 4.5) 44 79.5 (When regulating pressure = 82) 5.4 10 31.5
La Montaa 1,115 km. 16,5 P. Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
This is a legacy product, and replaced byZSE20-P-01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JC, ZSE30 1/8 PORTED, .28287 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever Type
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm)
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever Type
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm
This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .26179 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byZSE20-P-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .19453 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature
This is a legacy product, and replaced byZSE20-N-P-C4L-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 1E, ZSE30 OTHER SIZE RATING, .23658 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment
This is a legacy product, and replaced byZSE20-P-C6H-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 1E, ZSE30 OTHER SIZE RATING, .27557 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment
This is a legacy product, and replaced byZSE20F-P-C6L-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 1E, ZSE30 OTHER SIZE RATING, .29394 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment
DC24 V10% DC24 V10% DC(+) DC(-) 8 / / 9 () 10 / 5 m / 11 10 1015 "-M" ( ) (kPaMPa) "-M" 12 SI kPa,MPa -49NO.ZK2-OM00801-B No. 13 14 A () 15 () / ( ) () -50NO.ZK2-OM00801-B 80mA 3.5 F.S. 1 1 F.S. -51NO.ZK2-OM00801-B 100.0-100.0 kPa 105.0-105.0 kPa 500 kPa 0.1 kPa DC24 V 10(p-p)10() 40 mA NPN PNP OUT1OUT2 80 mA DC26.4 V 2 V (80 mA ) 2.5 ms (20,100,500,1000,2000 ms ) 0.2F.S
Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 2 - E/P Regulator Safety Instructions Caution 1. The product is provided for use in manufacturing industries.
Do not supply air pressure to ports other than the 1(P) port. If air is supplied to 2(A) port, air leaks from 1(P) port leading to operation failure. 4. Allows sufficient margin in the piping conditions of the tubing. 5. Prevent the connected tube from being rotated. If the fittings are used in this way, the fitting is likely to break. 4 Mounting ! Warning 1.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.