Common exhaust port for main and pilot valve (VF1000/3000) VFS VS4 VQ7 EVS VFN VF5000 C: 12 dm3/(sbar) {4/2 5/3 (A/B EA/EB)} 32 mm width VF3000 C: 3.1 dm3/(sbar) {4/2 5/3 (A/B EA/EB)} 26.4 mm width VF1000 C: 0.53 dm3/(sbar) {4/2 5/3 (A/B EA/EB)} 26.4 mm width 3-4-1 2 Series VF1000/3000/5000 Many combinations available to fit your needs.
B port Porting specifications Direction P: 1/8 R: M5 x 0.8 1/8 Port size M5 x 0.8 P, R port A, B port M3 x 0.5 M5 x 0.8, C4 (One-touch fitting for 4) Flow Characteristics Flow characteristics Port size 1 4/2 (P A/B) 4/2 5/3 (A/B R) Effective area (mm2) C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) Port 2(B), 4(A) Port Manifold Body ported for internal pilot Type SS5YJ3-20 SYJ32
(14.2) (b) (8) 2 1 (a) (14) (18) B1 A1 (17.7) 6 5 (c) 2 1 A6 B6 15 16 L (11) (30.7) 12.4 [820m] (a) (b) L E C P -* A B-1 2 L A A-1 1 B B-2 6 ) 8 8m B A-2 5 COM-A/COM B-3 3 ) A 10m COM-B/ A-3 4 ) B 15m (c) Shield ) C 20m Vcc B-4 12 GND A-4 13 A B-5 7 ) A A-5 6 () B B-6 9 B A-6 8 3 (14.2) (b) 2 1 (5.5) (14) (a) B1 A1 5 (17.7) 6 (c) 2 1 (18) A6 B6 (6.3) 16 15 L (11) (30.7) -82No.JXC-OMT0001CN-C
R a n g e M O D E < 1 . 5 C (Ex.: 1.5 C) Function : Sets upper limit of temp. where the warning arises. The difference between target temp. and upper limit temp. should be input. Therefore, if the target temp. is 23.0 C and 1.5 C is set in this item, the warning [WRN] arises when temp. exceeds 24.5 C. A l l o w a b l e L o w e r 7. Allowable Lower Temp.
A Section Thread Tightening Torque Model XLD(V)-25 XLD(V)-40 XLD(V)-50 XLD(V)-63 XLD(V)-100 XLD(V)-160 XLD(V)-80 Tightening torque 0.08 Nm (0.8 kgfcm) or less 0.3 Nm (3 kgfcm) or less 451 A XLD/XLDV Series Dimensions XLD/Air operated (b) E C D E C Fn (KF flange) (K flange) Fd (a) (c) Heater (Option) E Auto switch (Option) J K H S M B G A A (mm) A B C D E Fn Fd G H J K Model XLD-25 XLD-40
If 0.05 C is set in this item, the reading of temp. sensor is lower by 0.05 C and actually, the temp. is controlled to higher one by 0.05 C. 3. PB Range Setting range : 0.3 to 9.9 C Min. increment : 0.1 C Indicated content : PB range(Ex. : 2.0 C) P B R a n g e M O D E < 2 . 0 C Function : Sets PB (Proportional Band) range used for PID control. A R W R a n g e M O D E < 2 . 2 C 4.
7 @6 r w @9 @7 @8 e u @0 i y D A A D C-C D-D B-B !5 !1 !9 @3 #0 q @4 E C C E !4 !2 !0 !8 @1 !6 t o @2 @5 !3 Component Parts No. Description Material Note 1 2 3 4 5 6 7 8 9 No.
D C B A Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
For example, if -0.15 C is set here, the actual reference temperature for control is lower than the indicated SV by 0.15 C. O f f s e t V a l u e M O D E < 0 . 1 5 C A l l o w a b l e U p p e r T e m p . R a n g e M O D E < 1 . 5 C 6. Allowable Upper Temp.
B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
equipped with a limit indicator on which the prescribed pressure range can be viewed at a glance.
Auto switch mounting Auto switch model C85 Series C75 Series Bore size [mm] 8 10 12 16 20 25 32 40 D-M9l(V) D-M9lW(V) D-A9l(V)*7 BJ6-008 (A set of a, b, c, d) BJ6-010 (A set of a, b, c, d) BJ6-012 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) BM5-020 (A set of a, b, c, d) BM5-025 (A set of a, b, c, d) BM5-032 (A set of a, b, c, d) BM5-040 (A set of a, b, c, d) D-M9lA(V) BJ6-008S (A
4.9 2.2 2.7 2.8 Time (ms) Single NVFS5100 45 or less 2 Position Double NVFS5200 25 or less Closed Center NVFS5300 55 or less Exhaust Center NVFS5400 55 or less 3 Position Pressure Center NVFS5500 55 or less Perfect (Double Check) NVFS5600 60 or less T E C H N I C A L SPECIFICATIONS O P T I O N A L T E C H N I C A L SPECIFICATIONS S T A N D A R D Pilot Type External Pilot Type Fluid Air and
Body Material Aluminum Body Material Brass A A 2 x J 4 x J A A 2 x J 4 x J B C F B B C F B 1/8, 1/4, 3/8 1/8, 1/4, 3/8 1/8, 1/4, 3/8 1/8, 1/4, 3/8 C F C D E D E F D E D E Body Material: Aluminum [mm] Body Material: Brass [mm] Size Port size A B C D E F J 20 1/8, 1/4 11 36 6 34 46 1.5 5.3 30 1/4, 3/8 13 46 7 40 56 1.5 Size Port size A B C D E F J 20 1/8 52 24 9 36 64 1.5 6 20, 30 1/4, 3/8
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in) ZZ PC KK Y R XT G A LD Bore (in) DD C NT ND AA EA D B MM WF P K E SN TN EE 9.44 1.30 7/16-20 1.71 1.43 1 15/16 1.26 3/4 7.44 150 (1.5") 1/4-28 3/8 1/4-20 9/32 2.02 0.3 9/16 1 1/8 5/8 1 2.36 9/32 2 5.56 5/8 3/8 9.52 1.30 7/16-20 1.71 1.84 1 15
Class Class No. 1 1 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 1 2 1 2 C 3 4 F 1 2 3 4 5 6 7 E 9 10 1 2 3 4 5 6 F 9 1 2 3 4 5 7 8 9 1 2 3 4 5 6 1/8" A A B C D E F A B C D E F A B C D E F G A B C D E F G H A B C D E F 1 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 1/8" 1/8" 1/8" Branch tee female Run tee male Run tee female 1/4" A A 1/4
Also, indicate the option symbol "-K" for mixed wiring. w How to order applicable valves A B C A B C A B C A B C A B C SQ 1 1 4 1 C6 5 L A B C D E F G H I Series SQ1000 Switching type Electrical entry A E 1 2 3 4 5 A B C L type plug connector with lead wire L 2 position single 2 position double (latching/double solenoid) 3 position closed center 3 position exhaust center 3 position pressure