Cylinder Port: TF (G), Arm Opening Angle: 105°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A053 (70mm Offset Machined ref NAAMS ACA157M), L Arm Mtg Position: X [w/o Arm on Left Side (D Arm Position Type Only)], L Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)]
Cylinder Port: TF (G), Arm Opening Angle: 105°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A053 (70mm Offset Machined ref NAAMS ACA157M), L Arm Mtg Position: X [w/o Arm on Left Side (D Arm Position Type Only)], L Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], Painted Arm: P (Paint)
Cylinder Port: TF (G), Arm Opening Angle: 105°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: X [w/o Arm on Right Side (D Arm Position Type Only)], R Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], L Arm Mtg Position: A (Mounting Position A), L Arm Style: A053 (70mm Offset Machined ref NAAMS ACA157M)
Cylinder Port: TF (G), Arm Opening Angle: 105°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: X [w/o Arm on Right Side (D Arm Position Type Only)], R Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], L Arm Mtg Position: A (Mounting Position A), L Arm Style: A053 (70mm Offset Machined ref NAAMS ACA157M), Painted Arm: P (Paint)
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)
IR-A IR-A IR IRV Series Variations VEX Series Model Set pressure range (MPa) Port size SRH IR1000-A IR1000-A 0.005 to 0.2 SRP SRF IR1010-A 0.01 to 0.4 1/8 ITV IR1020-A 0.01 to 0.8 Basic Type (Knob) IC IR2000-A IR2000-A 0.005 to 0.2 ITVH IR2010-A 0.01 to 0.4 1/4 ITVX IR2020-A 0.01 to 0.8 PVQ VY1 IR3000-A IR3000-A 0.01 to 0.2 VBA VBAT IR3010-A 0.01 to 0.4 1/4, 3/8, 1/2 AP100 IR3020-A 0.01 to
Type S31 Manifold: Side Ported 91.7 [96.1] Approx. 300 (Lead wire length) SS5YJ3-S31Stations -M3 L1 L2 3.5 2-3.5 (For mounting) Manual override M5 x 0.8 (P, R port) 5.2 29.2 7.5 52.2 [54.4] 51.4 [53.6] 17.3 30 3 91.7 [96.1] 78.8 [83.2] 78.8 [83.2] 13.5 A A A A A B B B B B P R P R P R 29.2 P R 30 17.3 25 7.5 12 25 51.4 [53.6] 52.2 [54.4] 13.5 B B B B B A A A A A 3 5.2 2-3.5 (For mounting)
Recommended Proper Torque (Nm) Set nut (for bracket) IR12l0-A IR22l0-A IR32ll-A 2.00.2 Hexagon panel nut (for knob type only) IR12l0-A IR22l0-A IR32ll-A 3.50.5 788
Error Gr.1 A.320 Regenerative Overload Gr.2 A.330 Main Circuit Power Supply Wiring Error Gr.1 A.400 Overvoltage Gr.1 Alarm A.410 Undervoltage Gr.2 A.450 Main-Circuit Capacitor Overvoltage Gr.1 A.510 Overspeed Gr.1 A.511 Overspeed of Encoder Output Pulse Rate Gr.1 A.520 Vibration Alarm Gr.1 A.521 Autotuning Alarm Gr.1 A.710 Overload: High Load Gr.2 A.720 Overload: Low Load Gr.1 A.730 Dynamic
Operation in a vacuum condition When a valve is used for switching a vacuum, take measures to install a suction filter or similar to prevent external dust or other foreign matter from entering inside the valve. In addition, at the time of vacuum adsorption, be sure to supply a constant supply of vacuum.
turning On or Off with each input pulse COUNTER 16 Count upwards on pulses, can reset at a signal U/D COUNTER Count upward or downward, Set a Preset Value for the Output to come ON COMPARE 17 Compare two values for <,>,=,<=,>=,<> (Analog, Direct Set, or FB values) TIME SWITCH 2* Use the RTC to turn output On/Off; Calendar or weekly schedule OFFSET GAIN 22 Manipulate Analog Values; y = A/
Condensation A phenomenon where water vapor in the air turns to a liquid and adheres to a surface. Current consumption The max. current necessary to operate the switch normally. Does not include load current. D Shows how precisely the pressure can be indicated or set by the digital Pressure switch.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -39No.PS-OMV0009-E [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -36No.PS-OMV0004-H [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
(per unit) Applicable model A B C D HRSE012-AHRSE018-AHRSE024-A240 (335) 505 (540) HRW HRS-TK003 HECR HRSE012-A--T HRSE018-A--T HRSE024-A--T 240 (335) 555 (590) HEC HEB HED HEA IDH Anchor bolt (M8) D C (Prepared by user) Anti-quake bracket Material: Zinc steel plate Mounting view A B w Bypass Piping Set Note) To be mounted by user.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. a consumable part, so it is warranted for a year after it is delivered. a consumable part, so it is warranted for a year after it is delivered.
Regarding a vacuum switch When a valve is used for vacuum switching, use the valve external pilot specification. 9. Ventilation Provide ventilation when using a valve in a confined area, such as in a closed control panel.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injuty. Warning 1.