SMC Corporation of America
Elite Part Number Search
Search Results "VNB411A-F25A-5DZ-B-Q"

Stations: 8 Stations, Style: Q (DeviceNet), Manifold Mount Style: D (DIN Rail Mounting), Option: N (Name Plate), One-touch Fitting: ø8 (C8) One-touch Fitting, CE Compliant: Q (CE Marked)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: None, Port Size: A03 (Side Piping 3/8), Thread: F [G (PF)], Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 2 (200V AC), Option: N (Indicator Light), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF), Connector: Connector, Q: Q (CE Approval)

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: D (Double), Voltage: 1 (100V AC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: D (Double), Voltage: 3 (24V DC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: V (Individual Pilot EXH), Port Size: A03 (Side Piping 3/8), Thread: T (NPTF), Connector: Connector, Q: Q (CE Approval)

Symbol: FHG (3-Position, Closed Center), Solenoid: D (Double), Voltage: 3 (24V DC), Option: None, Port Size: A03 (Side Piping 3/8), Thread: F [G (PF)], Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 1 (100V AC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: S (Single), Voltage: 4 (12V DC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Symbol: FG (2-Position), Solenoid: D (Double), Voltage: 3 (24V DC), Option: None, Port Size: w/o Subplate, Thread: Rc (PT) (or w/o Subplate Type), Connector: Connector, Q: Q (CE Approval)

Model: 40 (Standard, AC Type), Bar Length: 52 (520mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 118 (1180mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 8L (ø8 Elbow), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 154 (1540mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: AL (ø10 Elbow), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)

Model: 40 (Standard, AC Type), Bar Length: 208 (2080mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: AL (ø10 Elbow), Plug Position: Q (High-voltage Cable Side), Bar Bracket: B (w/Bracket 1), Option: X10 (Non-standard Bar Length)