This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 10MM CXSJ CLEAN ROOM, ACTUATOR, CXSJ COMPACT CYLINDER, E5, 10MM CXSJ CLEAN ROOM, 0.44092 lb, ModelStandard stroke (mm) 102030405075100CXSJL100.1060.1210.1360.1510.1660.205?
Series CXS is available in six bore sizes and stroke lengths up to 100mm. This series is very compact and has a very accurate non-rotating specification. It is suited for accurate pick-and-place applications or light duty material handling. The CXS can be used with either reed or solid state switches. Available in clean room versions. Dual rod cylinder with ball bearing slide, Bore sizes
Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.
Do not continue idling except for priming the pump. 5 11. Condensation and freezing of the pilot port The location around the switching valve and the air exhaust port can cool down quickly due to expansion of the supply air, and this may cause condensation on the piping and the condensation may freeze during operation in winter.
Do not continue idling except for priming the pump. 5 11. Condensation and freezing of the pilot port The air supply port of the air operated type can cool down quickly due to expansion of the supply air, and this may cause condensation on the piping and the condensation may freeze during operation in winter.
Dimensions --11 7. Guaranteed term and guaranteed range 12 8. Parts replacement procedure 13 1 XL-OMP0001 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Operation failure Incorrect wiring (1) Fuse blown out and/or lead wire broken (2) Incorrect contact at the contact and connection (3) Broken wire in the coil (4) Foreign matter caught in the spool valve (8) Swollen spool valve (5) Excessive oil supply (11) Coil has burned out.
Model Thread size Tightening torque SX3000 M2 0.17 Nm SX5000 M3 0.8 Nm SX7000 M4 1.4 Nm 11 SX3000-OMM0002-B -12-SX3000-OMM0002-B -13SX3000-OMM0002-B TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.
When these products are installed in equipment, provide adequate protection against noise by using noise filters. 11.
SF: OFF BF: Red LED is ON 11 SF: Red LED is ON BF: Red LED is ON Address setting is defective. If the SI unit address is set to 0 or 126 or more, set it to between 1 and 125. SF: Red LED is ON BF: Red LED is flashing Configuration does not match. Check the configuration setting of PLC, and ensure it matches the actual configuration.
Fault No.11 Problem Possible cause Investigation method Countermeasures The inputs that are beyond the maximum point number do not operate. Check that the number of inputs has not exceeded the allowable number. The allowable number depends on the SI unit model. Inadequate total number of inputs from the Input block connected with the SI unit.
Description and Functions 9 5-1 LED indication 9 5-2 Terminal board 9 5-3 Address setting 10 5-4 Setting of Hold/Clear 11 6. Wiring 12 6-1 Communication wiring 12 6-2 Terminal resistance 13 6-3 Cable for communication line 13 6-4 Wiring to power supply 13 7. Troubleshooting 14 -1No.EX-OMF0012-B 1.
How to Use . 11 2-1. Procedures to operation . 11 3. Wiring . 12 3-1. AC adapter type/ IZG10-01, 02 . 12 3-2. Power supply cable type/ IZG10-03 . 12 4. Function . 13 4-1. Name of parts . 13 4-2. LED indication . 13 4-3. Mode setting switch . 14 4-4. Emitter maintenance (cleaning and replacement) . 15 4-5. Alarm function . 17 5. Performance . 18 5-1.
Recommended tightening torque: Modular AR/AW series 0.60.05 Nm ARM10/11 series 0.320.03 Nm Mount the main body of the Pressure switch. Insert the lock pin to the adapter to the end firmly. Supply pressure slowly, and ensure no air leaks.
And Adjust the offset voltage after supplying power. 23 Doc.No.IZ-OMK0015D (11) Timing chart Timing chart of normal operation Normal operation Reset operation Remarks Turn the power off to solve the problem, then supply power again. The error signal(OUT3) will be reset.
SeriesNCQ8 Air Cylinder: Standard Type Double Acting, Single Rod Maintenance Parts 056 to 400 Construction Double Acting, Single Rod 10 11 9 Seal Kit Parts List No. 9 10 11 Description Piston Seal Rod Seal Tube Gasket Material NBR NBR NBR *BLUE links will lead to purchase pages. Repair Parts: Standard Seal Kit for Double Acting, Single Rod Remarks Bore size Kit no.
Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions . Series AS-FG Speed Controller with One-touch Fittings Stainless Series In-line Type.
Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. Piping port (main) Top mounting For manifold Caution 1. Each valve is fixed on the manifold with two M4 mounting screws. Please tighten the screws properly when valves are reassembled. Screw tightening torque: 1.4 Nm 2.
VVZ200-32A-11 pc. VVZ400-32A-11 pc. Caution Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions.
(2.9) 5.5 50 Hz 60 Hz 50 Hz 60 Hz Inrush Apparent power (VA) (Power consumption (W)) VP AC Holding S070 Power consumption (W) DC Bracket (AXT338-11)/For body ported type VQ Accessory (Option) Indicator light Body ported Manual override VKF Note 1) Based on JIS B 8375-1981.