Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal w/o Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: H (Grommet, 600mm Lead Wire Length), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket)
Series: 742 (VP700), Pilot Type: Internal Pilot, Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: F (G), Actuation Type: A (N.C., Normally Closed)
Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: B (N.O., Normally Open), Bracket: F (Bracket)
Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: F (G), Actuation Type: B (N.O., Normally Open)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (10,15A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
/Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Z (Oil-free Specification), Port Size: 04 (1/2), Thread Type: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Bracket: B (Bracket)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (10,15A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Bracket: B (Bracket)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: B (Bottom Ported), Port Size: 04 (1/2)
Function: 4 (3 Position Exhaust Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)