Model: 23, Orifice Diameter: 6 (10 mm), Valve/Body Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread Type: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Bracket: B (Bracket)

Model: 23, Orifice Diameter: 6 (10 mm), Valve/Body Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 04 (1/2), Thread Type: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector)

Model: 23, Orifice Diameter: 4 (6 mm), Valve/Body Configuration: 1 (N.C. for Manifold), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Manifold Designation: 00 (Aluminum Base Material), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector)

Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector)

Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: Q (DeviceNetâ„¢), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: 6 Stations, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: C (Port Location U Side, Internal Pilot, Built-in Silencer), A,B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting

Body Style: A (Base Mounted w/Clips), Coil Voltage: 6 (12 VDC), Flow Rate: D (Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011), Electrical Entry: G (Grommet), Port Size: w/o Sub-plate, Made to Order: X26 (Special Lead Wire Length), Lead Wire Length: 6 (600 mm)

Model: Side Ported, SI Unit: CANopen, Negative Common, Input Block Stations: 6 Stations, Input Block Type: M8, 4 Inputs, PNP Input, Positive Common, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: D Side, 2 to 10 Stations, Internal Pilot, Built-in Silencer, A,B Port Size: ø10 One-touch Fitting, Straight, Metric, Mounting: DIN Rail Mounting w/o Name Plate, DIN Rail Option: -

Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~6, Compatible Fluid: Water / Chemical, Outer Diameter D(Ø): 6, Material: Fluororesin: [Standard Fluororesin] Super PFA, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): -, Applicable Tube Size:

Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Transparency, Outer Diameter Class: ~6, Compatible Fluid: Water / Chemical, Outer Diameter D(Ø): 6, Material: Fluororesin: [Standard Fluororesin] Super PFA, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 20, Applicable Tube Size

Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~6, Compatible Fluid: Water / Chemical, Outer Diameter D(Ø): 6, Material: Fluororesin: [Standard Fluororesin] Super PFA, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 50, Applicable Tube Size

Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Transparency, Outer Diameter Class: ~6, Compatible Fluid: Water / Chemical, Outer Diameter D(Ø): 6, Material: Fluororesin: [Standard Fluororesin] Super PFA, Operating Environment: Standard / Heat resistant / Chemical Resistance, Coil Winding Length(m): 100, Applicable Tube Size

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, CA, AR MASS PRO 1/8 MODULAR (PT), .44092 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator with Backflow Function Series AR KPages 346 through to 355AR20K1/8, 1/4BracketSquare embedded type pressure gauge (except the

The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is made of ozone resistant rubber material (HNBR) , Improved relief sensitivity , 6 Sizes , Rc, NPT or G(PF) threads, REGULATOR, AIRLINE EQUIPMENT, AR MASS PRO, CA, AR MASS PRO 1/8 MODULAR (PT

The ARP is a modular style, direct operated precision regulator.  A locking adjustment knob allows the pressure to be set, and then locked to prevent accidental setting changes. The ARP20/30/40 series is available with a back flow function that exhausts the air pressure in the outlet side reliably and quickly.  Special applications include (10-) clean room compliant, (20-)copper-free, fluorine-free

10%3023Refer to page 94.Contact input/output (D-sub 25 pin) and Serial RS-485 (D-sub 9 pin) (Refer to pages 92 and 93.)170UL, CE marking, SEMI (S2-0703, S8-0701, F47-0200), SEMATECH (S2-93, S8-95)

Base mounted plug-in manifold for VQ5*0* valve, Maximum 12 stations available as standard, D-sub connector reduces installation labor for electrical connection, D-sub connector - 25 pin, Select top or side receptacle position to meet available space requirement, 6 port sizes available, VV5Q manifold, 4/5 PORT SOLENOID VALVE, J57, 4500.00000 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available, SS5V 06 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID

The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available, SS5V 10 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID

The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available, SS5V 11 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID

D Digit Minimum unit for setting / display is 1 digit. When the minimum unit for setting / display is 5 L/min, 3 digits will be 3 x 5 = 15 L/min Display flow range The range which can be displayed by the product with a digital display. F Fluid temperature Range of fluid temperature that can be measured by the product.