ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 15 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, 55.00000 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 55 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 55 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 15 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 55 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., Low Profile Dig Pres Switch, VACUUM SWITCH, ZSE50-80, M46, 55 lb

Fluid: 0 (Air), Body, Port Size, Orifice: A [Resin (PPS); M5; 1.0], Voltage, Electrical Entry: E (230 VAC; Grommet), Option: C (M6 Thread)

Series: 3 (JSY3000), Type: 40 (Side Ported), Valve Stations: 8 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: M5 (M5 x 0.8), Thread Size: Rc, Mounting: D (DIN Rail Mounting), DIN Rail Option: 9 (Longer than Standard DIN Rail)

PF-OMK0003CN-E 0.320.02 Nm L () L () M4 (2 4 ) 1mm (22 ) -15No. PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: E (8mm), Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: E (8mm), Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)

Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 4 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: M5 (M5 x 0.8), Thread Size: N (NPT), Mounting: D (DIN Rail Mounting), DIN Rail Option: 5 (Longer than Standard DIN Rail)

Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 20 Stations, P,E Port Entry: D (D Side), A,B Port Size: M5 (M5 x 0.8), Thread Size: Rc, Mounting: D (DIN Rail Mounting), DIN Rail Option: 0 (DIN Rail Mounting, w/o DIN Rail)

Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 7 Stations, P,E Port Entry: D (D Side), A,B Port Size: M5 (M5 x 0.8), Thread Size: N (NPT), Mounting: D (DIN Rail Mounting), DIN Rail Option: 0 (DIN Rail Mounting, w/o DIN Rail)

Type: 332 (Body Ported), Valve Option: E (Continuous Duty Type), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: None, Port Size: M5 (M5 x 0.8), Thread: Rc with sub-plate, or Nil, Bracket: F (w/Bracket, Not Assembled)

Specifications: E (Oil-free, External parts copper-free), Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: M (w/M5, Female Thread)

Specifications: E (Oil-free, External parts copper-free), Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: M (w/M5, Female Thread)

Body Size: 2 (M5), Socket, Plug Type: P (Plug), Port Size: 04 (R, Rc(PT) 1/2 or Ø4 Tube), Connection: E (Bulkhead w/One-touch Fitting)

Body Size: 2 (M5), Socket, Plug Type: P (Plug), Port Size: 06 (R,Rc(PT) 3/4 or Ø6 Tube), Connection: E (Bulkhead w/One-touch Fitting)