Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 1 : Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Request to read Address BCC data End code Identification code Start code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address Start code BCC data Affirmation code End code Numerical data Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Symbol 0 1 2 Port size Port size Applicable model Symbol FQ1010 FQ1011 FQ1012 04 06 10 Rc1/2 Rc3/4 Rc1 Housing O-ring material Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Auto Switch Mounting Bracket Part No. 32 40 50 63 80 100 Auto switch model Bore size (mm) Bore size (mm) 40 32 50 63 80 100 Foot (1) MNB-L06 MB-L03 MB-L04 MB-L05 MB-L08 MB-L10 D-A5/A6 D-J5/F59F Flange MNB-F03 MNB-F04 MNB-F05 MNB-F06 MB-F08 MB-F10 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 Single clevis MB-C08 MB-C10 MB-C03 MB-C04 MB-C05 MB-C06 D-A3/A44 D-G39/K39 BMB2 -032 BMB2 -040 BMB1 -050 BMB1
MPa) Sub-atmospheric (A): 100 mm Hg absolute to 10 psig (-88 kPa to 0.07 MPa) Code Range options 1) Specification Code Ports 2 ports 3 ports Standard (Cv: 0.07) Code Specification Standard Sub-atmospheric 2PW 3PW No code 01 No code A High flow (Cv: 0.15) HF 1) Only available with SL5201. 0.5 to 30 psig (0.0034 to 0.2 MPa) 1 to 60 psig (0.007 to 0.4 MPa) 1 to 100 psig (0.007 to 0.7 MPa) 02 06
1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min} Effective area (mm2) 7.6 9.1 10.7 18.3 19.8 2.7 4.5 1.1 5.3 Note) Flow rate values are measured at 0.5 MPa and 20C. 15-9-14 2 Dual Speed Controller with One-touch Fitting Series ASD How to Order ASD 3 30F 01 06
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Specifications VR Operating type Air operated type Type of actuation N.C./N.O.
For details, please contact SMC. 3-11-17 18 Manifold Specifications Standard Specifications ISO Size 1 ISO Size 2 ISO Size 1 Maniflod block size VSR/S8-6 VSR/S8-8 VSR/S8-6 Applicable solenoid valve 1 to 10 Number of stations 1/4, 3/8, 1/2, 3/4, 1 A, B port Port size 1/4, 3/8, 1/2, 3/4, 1 P , EA, PB port VV82-P-03/04/06 VV81-P-02/03/04 Individual SUP spacer VV82-R-03/04/06 VV81-R-02/03/04
SV100 ANA1 -C08 T0604 SV200 ANA1 -C10 T0806 200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
SV100 ANA1 -C08 T0604 SV200 ANA1 -C10 T0806 200 CM2 32 400 MB 50 300 150 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS3201F -02-08 AS3000-02 200 100 100 50 0 0 200 CM2 40 400 MB 63 150 300 Stroke (mm) Stroke (mm) AS2201F -02-06 AS2200-02 100 AS4000-03 200 50 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
How to Order Manifold
A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.
R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R L 10 8 5 4 ZZMA Stations 06 ZL 10 10 8 6 ZZMA Stations 06B ZY R L 10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2. ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc.