SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS3-01T-052-02"

Base Mounted Wiring: Plug-in w/D-sub Connector on U Side, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/8, Control Unit: -

Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/4, Control Unit: -

Base Mounted Wiring: Plug-in w/Terminal Block, One-piece Junction Cover, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/8, Control Unit: -

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/8, Control Unit: -

Base Mounted Wiring: Base Mounted Plug-in w/Multi-connector on U Side, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/8, Control Unit: -

Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: NPTF1/8, Control Unit: -

Base Mounted Wiring: Plug-in w/Terminal Block, Individual Junction Cover, Stations: 5 Stations, Passage: 2 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Bottom], Port Size: 1/8, Thread: NPT, Control Unit: -, Voltage Air Release Valve: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 5 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Stations: 5 Stations, Passage: P: Common, EA,EB: Common, Port A,B: Bottom, Port Size: 3/8, Thread: NPTF, Control Unit: -, Voltage: -

Set stroke is outside the stroke limit. (052) B Input RESET If this alarm occurs, please input the reset signal, and then instruct the operation again. Return to the origin is not completed within the set time. Return to the origin was not completed within the set time (097) C Input Check if the movement of the actuator was interrupted.

Set stroke is outside the stroke limit. (052) B Input RESET If this alarm occurs, please input the reset signal, and then instruct the operation again. Return to the origin is not completed within the set time. Return to the origin was not completed within the set time (097) C Input Check if the movement of the actuator was interrupted.

(Including JOG operation after return to origin) The stroke is outside the stroke limit. (01-052) Make sure that the basic parameter, "Stroke (+)" and "Stroke (-)" are consistent with the distance of the electric actuator movement specified in the step data. limit B RESET Stroke input Caution If the operation method of step data is INC, take care with the position where operation

Set stroke is outside the stroke limit. (01-052) Stroke limit B RESET Caution If the operation method of step data is "relative coordinated movement", note the location where the operation starts and the distance traveled. If the location is out of the stroke range when the power is supplied, this alarm is generated. Move the table within stroke range, and supply power. -61No.

Set stroke is outside the stroke limit. (01-052) Stroke limit B RESET Caution If the operation method of step data is "relative coordinated movement", note the location where the operation starts and the distance traveled. If the location is out of the stroke range when the power is supplied, this alarm is generated. Move the table within stroke range, and supply power. -64No.

Set stroke is outside the stroke limit. (01-052) Stroke limit B RESET Caution If the operation method of step data is "relative coordinated movement", note the location where the operation starts and the distance traveled. If the location is out of the stroke range when the power is supplied, this alarm is generated. Move the table within stroke range, and supply power. -66No.

Set stroke is outside stroke limit. (052) B RESET is ON Caution If the step data operation method is a relative movement, note the location where the operation starts and the distance moved. If the location is outside the stroke range when power is supplied, this alarm will be generated. Move the table to within the stroke range, and supply power.

code <> FROM FROM Error (0-912) E <> <> Modbus (CI 1 Modbus Error (0-913) E 2 CI 3 4)OFF <> <> Module Error (0-914) E <> -87No.JXC-OMT0001CN-C (2) code <> [] (1) (2) >0 (3) (4) (5) (6) (7) Step data value is wrong (1-048) B RESET ON <> <> [] (1) (-)<(+) (2) < Parameter value is wrong (1-049) B RESET ON <> <> + JOG Set stroke is outside stroke <> + B RESET ON limit. (1-052

RESET Stroke limit (1-052) B SVON input Make sure that the basic parameter, Stroke (+) and Stroke (-) are consistent with the distance of electric actuator movement specified in the step data. 1. Return to origin is not completed within the set time. 2. Return to origin parameter has the conditions shown below.

Operation/ Shutdown 3.10.6 PID manual setting CH1 PID (control parameter) P Proportion band (050) i Integral time (051) d Derivative time (052) PID(proportion band / integral time / derivative time) is manually set. [ Setting range] P: 0.1 to 999.9 I: 0 to 3200 sec. D: 0.0 to 999.9 sec. PID values are automatically set by auto tuning.