Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Pipe Port Type: M, Port Size: M3, Pressure Rating(MPa): 0.2 to 0.7, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type
Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Low Vacuum Compatible / Lubrication Free / Copper-Free Fluoropolymer Material / Low Current, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: M, Port Size: M3
Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Low Vacuum Compatible / Lubrication Free / Copper-Free Fluoropolymer Material / Low Current, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M3
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Specifications: Power Saver, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: Body Ported M3X0.5, Option: -, CE Marked: -
Function: 2 Position Single, Piping: Body Ported, Exhaust: Common, Specifications: Standard, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: Body Ported M3X0.5, Option: -, CE Marked: -
Function: Normally Closed, Piping: Body Ported, Body Option: Common EXH, Specifications: Standard, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Body Ported, Body Option: Individual EXH, Specifications: Power Saver, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
Function: Normally Open, Piping: Body Ported, Body Option: External Pilot, Specifications: Standard, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Body Ported, Body Option: Individual EXH, Specifications: Standard, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: Light & Surge Suppressor, Manual Override: None, Port Size: Body Ported M3X0.5, Bracket: -, CE-Compliant: -
How to Order JA 40 F 14-150 Option Mounting type None Nil High temperature specifications 5 to 100C Nil F L Basic type Flange type Foot type Applicable bore size (mm) X11 Symbol Applicable bore size (mm) Model 6 10 15 20 30 40 63 80 100 140 160 6 10 10, 15 20 25, 32 40 50, 63 80 100 125, 140 160 Thread nominal size (Standard) Nominal thread size Applicable cylinder nominal thread size Standard
M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 MSQ MRQ Symbol: A4 Symbol: A5 Symbol: A3 The long shaft can be further shortened by machining it into a stepped round shaft. (If shortening the shaft is not required, indicate for dimension X.) (If not specifying dimension C1, indicate instead.)
Table deflection due to yaw moment load Displacement at A when load is applied F Table deflection due to roll moment load Displacement at A when load is applied F A A F A F F L L L L dimension mm L dimension mm L dimension mm MXY6 MXY6 MXY6 100 100 100 MXY8 MXY8 MXY8 100 100 100 MXY12 MXY12 MXY12 140 140 140 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-
Max. 0.1 mg/m3 (ANR) Note 2) Downstream oil mist concentration (Before oil saturation, 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) When 2 years passed, or pressure drop reaches 0.1 MPa Element life Refer to Best Pneumatics No. 5 for further details. Note 1) With auto drain is 0.1 MPa (N.O. type), 0.15 MPa (N.C. type).
Metric Long stroke Standard stroke Without auto switch With auto switch A Long stroke L1 24 25.5 28.5 32.5 Long stroke (mm) Standard stroke (mm) Standard C Bore (mm) Bore (mm) With/Without auto switch A C1 H1 X Inch L1 14 15.5 18.5 22.5 B 22 22 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 A B 32 32 41 44 F 7.5 7.5 9 11 L B 17 17 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 Metric 6 8 7 12 12 16 20 25 12 16 20 25 9 10
: MDHR3-10R 11221122MDHR3-10E port location 3 x M3 x 0.5 thread depth 6 P.C.D.24 A (Mounting thread) 17.5 20 120 120 40 2-3 B 8.5 25 Finger closing port M3 x 0.5 M3 x 0.5 25 Finger closing port Finger opening port M3 x 0.5 M3 x 0.5 9.5 Finger opening port 44 +0.02 2 x 3 0 depth 6 31 (A, B common view) 0 9h9-0.036 4 x M3 x 0.5 thread depth 6 2 x 4.2 (A, B common view) 9.7 4.7 1 19.5 10.1 5.8
Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F = x m g (N) 1. Calculation of applied lateral load F The lateral load F equals the coefficient between the work piece and the conveyor. Thus, from the total amount of the work piece and coefficient of friction, F = x m g (N) 2.
port) S + Stroke N 52 3 x 1/4 (Rc, NPT, G) (Piping port) 20 17 30 10 W 2 x Speed controller valve Top width across flats 3 11.5 3 14 45 45 M16 x 1.5 45 Hs 30 IA IB 40 35 20 38 Width across flats 17 F 4 x M6 Thread depth 12 R15 0.050 d90.093 +0.027 H8 0 Shaft: 12 Hole: 12 97 ZZ + Stroke Z + Stroke Clevis width CKP1A: 16.5 CKP1B: 19.5 CKP1C: 12.5 +0.3 0 +0.4 0 +0.5 0 Unit: mm 40 Symbol F IA