In such cases, the entire silencer case assembly needs to be replaced. 4 For nozzle size 07, 10 6 For nozzle size 12, 15 8.2.4.
Description 40 I 50 63 QI Coil scraper MDH-20 Phosphor bronze a; Rod packing NBR DRP-20S 'O! 4D 4P Ii) I I NBR NLP-40 Piston packing NLP-SO NLP-63 I: NBR CM-040-16-127 Tube gasket CM-OSO-16-1 28 CM-063-16-129 I Plastic C1AOSO-07-306 C1A040-07-30S Wear ring C1A063-07-307 NBR Cushi9n packing A MC-2S $ I MC-25 NBR . Cushlb!')'p8cking B MC-20 MC-20 "qr .,. Gasket tor GusHi<:>n va 've.
SRF 1 07 11 0 S S 1 With nut Body size 1 3 5 Fitting type Pilot port thread type Made to Order (Refer to page 887 for details.)
Size: 2 (M5 Basis), Tube Size: 07 (Ø1/4"), Exhaust Port: 07 (Ø1/4")
ZK2-OM01301 (9) DIN rail AXT100-DR 5 Length symbols 1 to 40 L = 12.5 x # + 10.5 (#: Length symbols 1 to 40) L Dimension (When selecting the number, refer to L6 in dimension table in the Best Pneumatics No.4 catalog.)
01 M5 x 0.8 Rc 1/8 (A port) For the port size 01 only.
Grease pack part number: GR-S-010(10g) , GR-S-020 (20g) Wear ring number 32 CM-32-07-304B 40 C1A040-07-305B 50 C1A050-07-306B 63 CA1063-07-307B 80 C1A080-07-308B 100 C1A100-07-309B 125 C1S125-07-362 C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2.
Grease pack part number: GR-D-005 (5g), GR-D-010 (10g), G-D-100 (100g) Table 13 Wear ring Wear ring number 40 C2A40-07-305B 50 C2A50-07-305B 63 C2A63-07-305B 80 C2A80-07-305B 100 C2AA0-07-305B C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2.
Selection Graph (2)-1 Pad Diameter Selection Graph by Lifting Force Vertical Lifting (2 to 50) Selection Graph (1)-1 Pad Diameter Selection Graph by Lifting Force Horizontal Lifting (2 to 50) 50 40 32 25 20 16 13 10 8 50 40 32 25 20 16 13 10 8 -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa -80 kPa -70 kPa -60 kPa -50 kPa -40 kPa Pad diameter (mm) Pad diameter (mm) Pad diameter (mm) 6 6 4 4 2 2 Lifting
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006
Pad diameter/form Silicone rubber Urethane rubber FKM ZHP63BM 2.9 0 20.3 ZHP80BM 5.0 0 35.1 ZHP63UM 1.5 0 10.6 ZHP80UM 2.1 0 15.5 255 ZHP Series Exhaust Characteristics/Flow Rate Characteristics (Representative Value) Flow Rate Characteristics Exhaust Characteristics ZHP-07 ZHP-07 (Supply pressure: 0.35 MPa) 50 45 40 35 30 25 20 15 10 5 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30
Metric sizes Inch sizes Body Class Type LQ-GP J PAX 3 03 03 10 10 10 12 12 12 19 19 19 25 25 1/8" 03 03 03 03 3/16" 05 05 1/4" 07 07 07 3/8" 11 11 1/2" 13 13 3/4" 19 19 1" 25 4 04 04 04 04 6 06 06 06 8 08 Insert pin holder assembly (with the parts case) Type Insert pin/ Holder type 1 2 1 2 3 4 5 6 J PB Insert pin material (J/K type only) Nil N Metric sizes Inch sizes Nil S Resin
Wear ring number Wear ring number 40 C1A040-07-305B 50 C1A050-07-306B 63 C1A063-07-307B 80 C1A080-07-308B 100 C1A100-07-309B C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2. Storage of seals C a u t i o n Store seals in sealed packaging such as polyethylene bag and place it in a box.
5 to 40 Circulating fluid flow setting range*4 L/min 10 to 40 10 to 40 Circulating fluid discharge pressure display range MPa 0 to 1.5 0 to 1.5 -30 to 40C: Galden HT135*5 FluorinertTM FC-3283*5 20 to 90C: Galden HT200*5 FluorinertTM FC-40*5 Circulating fluid (No intrusion of foreign body) Refrigerant R404A (HFC) R404A (HFC) Quantity of refrigerant kg 2.9 0.72 (At 20L/min) 0.72 (At 20L/min
(located on both the right and left side) Before disassembly, be sure to check that no inlet or outlet pressure is applied and exhaust the internal pressure thoroughly before starting the job. 707 Regulator Single Unit Type ARM5S Series How to Order A 07 S ARM5 Single unit type 1.
Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2
JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.
Size: 2 (M5 Basis), Style: 2 (Elbow), Thread: M3, M5, U10/32, R, Port Size: 10-32 UNF, Tube Size: 07 (1/4"), Sealant: w/o Sealant (M3,M5,U10/32), Option: None, Made to Order: None, Lock Nut: J (Round)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 0°, Thread: R, Port Size: M5 (M5 x 0.8), Applicable Tubing O.D.: 07 (ø1/4)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 3 (Universal), Control Type: 1 (Meter-in), Indicator Direction: 1(180°), Thread: R, Port Size: M5 (M5 x 0.8), Applicable Tubing O.D.: 07 (ø1/4)