MHC2 Installation MHT2 0 01 MHW MHW2-50 MHY2 Warning Warning MHW2 When using right angle finger tap mounting type, pay attention the interference of bolt and speed controller. When using speed controller with One-touch fitting, use AS22 or AS23. If AS32 or AS33 is used, the finger interferes with speed controller as figure shown below. It causes malfunction.

DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 7 Plate Cylinder with Lock Series MLU Single knuckle joint Double knuckle joint MM C (R1) Sphere, ball R (R1) MM NDH10 NDH10 A1 A1 NX+0.4 +0.2 E1 NX -0.2 -0.4 NZ E1 U1 U1 L1 NO NL L1 NO NL (mm) Part no.

{(16 A) (54 B) (88 C)} 2304 A: Number of remote I/O stations 64 B: Number of remote device stations 42 C: Number of local stations 26 (d) When the number of units connected is 4, station numbers can be set as shown below.

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS090 Series 5-20 HRX-OM-T004 Chapter 5 Simple communication

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRSH Series 5-20 HRX-OM-R028 Chapter 5 Simple communication

Valve diagnostics 1 . 5-4 Valve diagnostics 1 Bit 0 Valve 0, 1 diagnostics 01() 1 Valve 2, 3 diagnostics 01() 2 Valve 4, 5 diagnostics 01() 3 Valve 6, 7 diagnostics 01() 4 Valve 8, 9 diagnostics 01() 5 Valve 10, 11 diagnostics 01() 6 Valve 12, 13 diagnostics 01() 7 Valve 14, 15 diagnostics 01() 5.1.1.4.

Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 P362030-201 Bracket P36201023 P36202028 Pressure gauge234 G33-2-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 G33-4-01 G43-4-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached

AL.01 to AL.32 D.OUT1 ALARM CODE No.15 screen Contact output signal 1 maintenance MT.01 MT.01 to MT.05 D.OUT1 MANT CODE No.16 screen Contact output signal 2 function RMT 1 D.OUT2 SEL No.17 screen Contact output signal 2 operation A A/B D.OUT2 TYPE No.18 screen Contact output signal 2 alarm AL.01 AL.01 to AL.32 D.OUT2 ALARM CODE No.19 screen Contact output signal 2 maintenance MT.01

Description 0 1 0 1 VY110 0 1 VY120 0 1 VY130 0 1 0 1 0 1 VY140 VY170 0 1 VY190 0 1 VY1D00 VY150 VY1B0 VY1A0 ITV B F G N AN120-M5 VEXA-18-2A VEX1-18-1A VEX3-32A VEX5-32A VEX7-32A VEX9-32A Bracket (With bolt, washer) IC VEXA-18-3A VEX1-18-2A G27-10-01 AN120-M5 G36-10-01 AN101-01 AN120-M5 G46-10-01 AN210-02 G27-10-R1-X207 Pressure gauge ITVH Pilot EXH port silencer ITVX Sub-plate and Base Gasket

<> (01-144) D RESET SVON <> <>(M24V) (01-145) RESET SVON D <> <> <> RESET SVON (01-146) D <> -65- <> <>(C24V) RESET SVON (01-147) D <> <> <> (01-148) RESET SVON D <> <> (01-149) D RESET SVON <> () Communicati on error. (01-150) D RESET SVON <> (01-192) E <> <> <> ON(SVONON) (01-193) E <>ON(SVON ON) <> Output current limit is exceeded set value (

Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020 / 2120 IR3000 IR3010 IR3020 / 3120 Bracket P36201023 P36202028 P36203018 Pressure gauge G33-2-01 G33-4-01 G43-4-01 G43-4-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-10-01 Accuracy 3% (full span) 2 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 Fixed throttle SUP side passage OUT side passage SUP side passage SUP side passage

(With bolt and washer) G27-10-R1-X207 G27-10-01 G36-10-01 G46-10-01 G Pressure gauge AN120-M5 N Silencer for breed port (PE) The optional parts are shipped in the same package.

AW20P-270AS AR20P-260S G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD27 AR30P-270AS AR30P-260S G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38N Note) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48N Note) Set nut Round 1.0MPa Note 2) Note 3) Pressure gauge Square embedded type Round 0.2MPa Note 3) Square embedded type N.O. N.C.

G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer

Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 3 Select function 21. Press the [] key. Displays screen for setting the function of the Contact output signal 3.

Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 3 Select function 21. Press the [] key. Displays screen for setting the function of the Contact output signal 3.

Symbol Parts name VEX11001 02 VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 VEX3-32A VEX5-32A VEX7-32A VEX9-32A VEX1-18-1A G27-10-01 G36-10-01 B F G Bracket (with bolt and washer) Air operated External pilot solenoid G46-10-01 VEX1-18-2A Pressure gauge (1) Note 1) When requring the gauge except mentioned above, specify the model number.

For 20A/20B 25 5 1.5 4 x 2.6 Depth 7 or less Atmospheric vent port 30 20 30 20 Lead wire with connector M5 x 0.8 Thread depth 3.5 01 4 x 2.6 Depth 7 or less Atmospheric vent port 15.2 R1/8 7.2 N01 NPT1/8 A Piping specification Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width across flats 12 20 ZSE20(F)/ISE20 Series Dimensions With bracket ZSE20(F) ISE20 Option 2 30 A1 25 20 Bracket

1 Valve 2, 3 diagnostics 01 2 Valve 4, 5 diagnostics 01 3 Valve 6, 7 diagnostics 01 4 Valve 8, 9 diagnostics 01 5 Valve 10, 11 diagnostics 01 6 Valve 12, 13 diagnostics 01 7 Valve 14, 15 diagnostics 01 Valve diagnostics 2 . 5-5 Valve diagnostics 2 Bit 0 Valve 16, 17 diagnostics 01 1 Valve 18, 19 diagnostics 01 2 Valve 20, 21 diagnostics 01 3 Valve 22, 23 diagnostics 01 4 Valve 24, 25

17.5 42 62 M14 x 2 35 M12 x 1.75 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z Nil TN TF 80 (56 x 2) 10.6 17.5 10 Rc1/4 NPT1/4 G1/4 24.5 23 37 38 64 55 155 118 184 25.5 42 M12 x 1.75 18 9.5 100 (71 x 2) 12.5 20 12 Rc1/4 NPT1/4 G1/4 31.5 25 38 40 74 71 187 141.5 219 27.5 46 M14 x 2 21 11 9 JMGP Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke