D-A93 D-M9B D-M9N Load voltage 24 VDC 28 VDC or less 24 VDC (10 to 28 VDC) Load current range Indicator light 5 to 40mA (24 VDC) 40mA or less 5 to 40mA Relay, PLC IC circuit, Relay, PLC 24 VDC Relay, PLC 3-wire type Solid state switch 2-wire type PLC: Programmable Logic Controller Refer to applicable auto switch list Page 182.
to +24 VDC (Voltage: Between 19 VDC and power supply voltage, Current consumption: 5 mA or less) Input signal Static electricity removal completion signal Maintenance detection signal Error signal Sensor monitor output Note 3) Max. load current: 100 mA Residual voltage: 1 V or less (Load current at 100 mA) Max. applied voltage: 28 VDC Max. load current: 100 mA Residual voltage: 1 V or less
(Example 1) Users system side To the thermo-chiller 24 VDC +24 VDC (Output) 1 2 +24 VDC (Input) EXT 24 VDC EXT 24 COM Power supply 14 24 COM (Output) 24 COM Run/Stop When using a users power supply, connect the 24 VDC + side to pin 2 and the COM side of each contact input signal to the users power COM.
B2 Supply valve (N.O.) 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: Lead wire length 300 mm L: With lead wire (300 mm) M: With lead wire (300 mm) MN: Without lead wire U With light/surge voltage suppressor (Non-polar type) r Rated voltage DC CE-compliant 5 24 VDC V 6 12 VDC V V 6 VDC V S 5 VDC V R 3 VDC V * For type U, only DC voltage is available
, Class2, 2 A Power supply (Output) 24 VDC, Class2, 2 A Applicable series VQC1000/2000/4000/5000, SV1000/2000/3000, SY3000/5000/7000, S0700 Solenoid valve Max. number of solenoid valves 32 solenoid coils Output type of solenoid PNP (Negative common) Connected load Solenoid valve with surge voltage suppressor 24 VDC, 1.0 W or less (SMC) Short circuit protection YES Protocol Ethernet POWERLINK
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Note) For the special voltages, please consult with SMC.
D: Push-turn locking slotted type 3 position exhaust center Elbow fitting assembly (Upward) L4: 4 elbow fitting assembly L6: 6 elbow fitting assembly (A) 4 (B) 2 4 5 (EA) 1 (P) 3 (EB) A 4 3 position pressure center Rated voltage B 2 (A) 4 (B) 2 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 5 Elbow fitting assembly (Downward) B4: 4 elbow fitting assembly B6: 6 elbow fitting assembly 5 (EA) 1 (
Piping Specifications Model 01 N01 C4H C6H N7H C4L C6L N7L R1/8 M5 x 0.8 NPT1/8 M5 x 0.8 Port size 4 mm 5/32 inch One-touch fitting, Straight type 6 mm 1/4 inch 4 mm 5/32 inch One-touch fitting, Elbow type 6 mm 1/4 inch Sensor pressure receiving area: Silicon Sensor pressure receiving area Wetted parts material PBT, POM, Stainless steel 304, C3604 (electroless nickel plated) O-ring: NBR
VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 A1 A2 A3 LW06 LW2 LD4 LD8 100 VAC 200 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 4-13-3 4 For details about the applicable products conforming to international standards, visit us at www.smcworld.com. 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry
pin) Number of outputs 8 outputs (2 outputs/connector) 16 outputs Output specifications Power supply voltage (Control and input) 24 VDC Class2, 2 A Power supply voltage (Output) 24 VDC Class2, 2 A Max. load current 0.5 A/output 2 A/unit Protective function Short circuit protection Acceptable electric wire 0.08 to 1.5 mm2 (AWG 16 to 28) Current consumption 50 mA or less Enclosure IP67 (With
Specifications 32 Dimensions 34 -1No.EX-OMW0016-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Display the required function number and press the button. : The sub screen displays the content of function and the setting of the function alternately. -29No.PF-OMM0005-N Default settings Item Default setting Page [ oU1] Output mode (OUT1) [ HYS] Hysteresis mode Page 32 [ 1ot] Switch operation (OUT1) [ 1_P] Normal output Page 32 50% of maximum rated flow [ 2.00] 2.00 L/min (4 L type) [
OUT2 White OUT2 Load Load Blue DC () Blue DC () -R: NPN (2 outputs) + Copy function -S: NPN (2 outputs) + Copy function -T: PNP (2 outputs) + Copy function -V: PNP (2 outputs) + Copy function Brown DC (+) Brown DC (+) Load Gray Copy terminal1 Gray Copy terminal1 + + Black OUT1 Black OUT1 12 to 24 VDC 12 to 24 VDC White OUT2 White OUT2 Blue DC () Blue DC () *1 Refer to page 32. 14 ZSE20
Specifications 32 Dimensions 34 -1No.EX-OMY0021 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
AL Turbine Oil Class 1 (With no additives), ISO VG32 ISO viscosity grade Viscosity classification cSt (40C) ISO viscosity grade 32 Viscosity classification cSt (40C) 32 Idemitsu Kosan Co.,Ltd. Kygnus Oil Co. Turbine oil 32 Turbine oil P-32 Composite effective area (mm2) Model Kyushu Oil Co. Stork turbine 32 Turbine oil 32, Mitsubishi Turbine 32 Nippon Mitsubishi Oil Corp.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
Class 1 turbine oil (with no additive), ISO VG32 Diana Fresia S32 Turbine Oil 32 Cosmo Turbine 32 Turbine 32 Turbine Oil 32 Fucoal Turbine 32 Winding direction Expose approx. 1 thread Pipe tape Please contact SMC regarding class 2 turbine oil (with additives), ISO VG32.
Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply EX260-SDN1/-SDN3 PNP (negative common) / source Output type EX260-SDN2/-SDN4 NPN (positive common) / sink EX260-SDN1/-SDN2 32 outputs Number of outputs EX260-SDN3/-SDN4 16 outputs Solenoid valve connecting specification Connected
Supply a voltage of 24 VDC 10% to the product. PWR: Green flashing Power supply voltage is abnormal. Check that a voltage of 24 VDC 10% is applied. Power supply voltage is abnormal. Check that a voltage of 24 VDC 10% is applied. ST: Green flashing Short circuit on input or output ports. Check for a short circuit on the devices connected to the Air Management Hub rear side.
ON voltage 21.6 VDC or more OFF voltage 4 VDC or less Residual voltage 2 VDC or less Current leakage 0.1 mA or less Current leakage 1 mA or less ..