Failure of the power supply for the input and control Supply 24 VDC 10% to the power supply for the input and control.
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.
Refer to Self-holding function of supply valve on page 23 (4) Rated Voltage Note 9) Symbol Voltage 5 24 VDC 6 12 VDC 0 When (3) is N Note 9) Rated voltage for the supply and release valve -9No.
Refer to Self-holding function of supply valve on page 23. (4) Rated Voltage Note 9) Symbol Voltage 5 24 VDC 6 12 VDC 0 When (3) is N Note 9) Rated voltage for the supply and release valve -10No.
, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC Command signal IR 12 VDC 10%, 24 VDC 10%, 1.8 W or less Power supply Electrical entry DIN terminal VEX Applicable cable Cable O.D. 4 to 6.5 When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa) Bleed air flow AMR Installation Universal ITV (3) Lubrication Not required Note 1) The weight of the base mounting type
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
-T PNP (2 outputs) + Analog voltage output -T/-V PNP (2 outputs) + Auto-shift input Brown DC (+) Brown DC (+) Brown DC (+) Gray Analog output Gray Auto-shift input Gray Analog output Main circuit Main circuit Main circuit Main circuit Load Load + + + Black OUT1 Black OUT1 12 to 24 VDC Load 12 to 24 VDC Load 12 to 24 VDC Black OUT1 Black OUT1 White OUT2 Black OUT1 White OUT2 Black OUT1
B10 Input Signal Output Signal Name Details Connect a 24 VDC power supply for the input signals.
12 VDC SRP PVQ30 (2.3) SRF 120 ARX20 P = 0.35 MPa 100 P = 0.25 MPa VCHR Flow rate (l/min) 80 P = 0.18 MPa ITV 60 P = 0.1 MPa 40 IC 20 PVQ 0 0 0 20 40 40 80 60 120 80 160 100 200 120 240 140 280 160 320 180 360 200 400 Current (mA) 24 VDC 12 VDC VEF VEP VER PVQ30 (4.0) VEA 120 100 P = 0.12 MPa VY2 Flow rate (l/min) P = 0.08 MPa 80 VBA VBAT P = 0.06 MPa 60 AP100 40 P = 0.04 MPa 20 0 0
(Symbol 1) IN (Symbol 2) OUT Nil 300 mm 600 mm 1000 mm For the LVM11, the type with power-saving circuit is standard. 6 10 Coil voltage 10R4 N.O. 2 Option (Symbol 3) IN (Symbol 2) OUT Symbol Voltage Nil None Bracket Manual override Bracket, Manual override 5 6 24 VDC 12 VDC 1 2 3 10R6 N.C.
The 24 VDC power supply for the controller (CN1), and the 24 VDC power supply for the parallel I/O (CN5) should be separate. 42 Parallel I/O connection check The wiring and connections and the signal status of the controller and PLC can be checked using the I/O status and Manual Output functions.
(Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range "HHH" is 6 12 to 30 VDC. displayed. (1) Reset applied pressure to (1) Check if the pressure exceeds the a level within the set pressure range.
input and controling GW 24 VDC GW unit 4 2 3 7 8 Accessory No.
D-P5DWL Auto switch model Applicable load 24 VDC relay, PLC Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less Internal voltage drop 5 V or less Leakage current 1 mA or less at 24 VDC Operating time 40 ms or less Operating positionRed LED lights when ON. Optimum operating positionGreen LED lights when ON.
Features 4 PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage 24 VDC Power supply line 2 A Rated current Communication line 0.3 A Insulation resistance 5 M or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque 0.4 to 0.6 Nm/0.4 to 0.7 Nm Terminal block specifications Wire stripping length (recommended) 7 mm Connecting wire
Check if there is a noise source nearby. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range 12 to 30 VDC. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range. "LLL" is displayed.
Check if there is a noise source nearby. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range 12 to 30 VDC. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range. "LLL" is displayed.
10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.
100/150 Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal HRSH 090 HRSH To the thermo-chiller Users equipment side HRSE 7 24 VDC 6 24 VDC output (500 mA MAX) 5 HRZ 15 14 HRZD 24 VCOM output 13 24 VCOM HRW Signal description Default