Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Weight 1.24 kg Rc 3/8, 1/2: 2.20 kg, Rc 3/4: 2.81 kg Note 1) Set the inlet pressure by 0.05 MPa or larger than the required maximum set pressrue.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 IF Data Can be integrated with ZX or ZR ejector system.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Compact, lightweight and large valve capacity Diaphragm VX3 ! VXA VN Wide variations enables a wide range of fluids control.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Refer to Made to Order Specifications on pages 14-20-55 to 14-20-57.
Applicable to 200 to 230 VAC, or 380 to 415 VAC Operable from a distance. Transformer unnecessary Power supply Transformers are unnecessary even when used overseas. Step-down transformer 380 VAC 200 VAC Current model Step-down transformer Unnecessary 380 to 415 VAC HRS090 Convenient functions (Refer to the Operation Manual for details.)
Corrected air flow capacity = 130 SCFM (0.78 x 0.78 x 0.93) = 230 SCFM Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air flow rate (Correction factor A x B x C) 3 Select the model. The model which exceeds the correct air flow capacity of 230 SCFM is IDFB80.
JIS symbol 1/8, 5/32 3/16, 1/4 3/8 5/16 3/16, 1/4 1/4 3/16 1/4, 5/16 1/2 Inch sizes 3/8 5/32 Flow rate l/min (ANR) {Nl/min} 920 660 230 420 1390 290 460 1050 100 130 Controlled (Free) Effective area mm flow 14 10 3.5 6.5 21 4.5 7 16 2 1.5 1l/min=0.035SCFM 18mm2=1Cv Note 1) Flow rate values are at a pressure of 0.5MPa (72.5psi) and temperature of 20C (68F).
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VR Port size Type of actuation Nil Without sub-plate VH Normally open Normally closed 2 1 M5 port with sub-plate M5 VHS How to Order Manifold Base Same manifolds as Series SYJ300 are prepared. SS3YJA3 Fill the same as SS3YJ3.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Manifold Model Model VOA301 Applicable manifold model Common/lndividual exhaust Accessory (Part no.)
V100 SY SYJ VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT Grommet VP Exploded view VG VP (1) Bleed groove Bleed port on main valve (4) S070 (7) VQ Bottom of the solenoid valve (5) VKF 2.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5 3 position pressure center Port size VR W/o sub-plate (Pilot port: Rc) W/o sub-plate (Pilot port: Other than Rc) 1/4 3/8 Nil VH 00 VHS 02 03 How to Order Manifold Base 10 1 2 VV5FRA3 n Port size Thread type Indicate the same part number as VFR3000 manifold
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VPA4270-14 Port size VR VPA4150-04 Port size Applicable valve model Note) 3 position is not available on Series VPA470.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com JIS Symbol Single solenoid VZS 4 2 VFS Rated voltage VS4 5 1 3 Double solenoid Electrical entry VQ7 4 2 Apparent power AC (Power consumption) EVS 5 1 3 Electrical entry VFN Note 1) Use dry-air at low temperature.
M6 x 25 AXT335-12-3 AS568-015 Hexagon socket head screw Gasket O-ring i o Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Part no.
LED In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC. For 115 VAC and 230 VAC, the allowable voltage is 15% to +5% of rated voltage. Response Time Note) Based on dynamic performance test, JIS B 8375-1981.
AV Flow rate (m3/min (ANR)) AU Inlet pressure 0.5 MPa AF Inlet pressure 0.4 MPa Piping AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Warning IR If installing an air tank, install it upstream of the bypass oil feed adapter.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.03 s or less 0.03 s or less 0.05 s or less 0.05 s or less Response time Hysteresis 3% F .S. IR Repeatability 3% F .S. VEX Sensitivity 0.5% F .S.
Supply voltage Internal voltage drop of switch Voltage of operation load > Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 Body material: Bronze, Stainless steel VXA Cylinder actuation by external pilot air VN LVC LVA Large valve capacity PTFE seal LVH LVD LVQ LQ LVN Wide variations TI/ TIL 2 types N.C., N.O.
VX2 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piping Caution VX3 When high temperature fluids are used, use fittings and tubing with heat resistant features. (Self-align fittings, Teflon tubing, Copper tubing, etc.)