SMC Corporation of America
Elite Part Number Search
Search Results "RZQB50TN-50-5"

Class Class No. 1 1 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 1 2 1 2 C 3 4 F 1 2 3 4 5 6 7 E 9 10 1 2 3 4 5 6 F 9 1 2 3 4 5 7 8 9 1 2 3 4 5 6 1/8" A A B C D E F A B C D E F A B C D E F G A B C D E F G H A B C D E F 1 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 1/8" 1/8" 1/8" Branch tee female Run tee male Run tee female 1/4" A A 1/4

5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.

9, @0, @2, @3, @4, @5 NBR 32 RHC32-PS @4 O-ring NBR 40 RHC40-PS @5 O-ring Stainless steel for 20, 25 Carbon steel for 32, 40 10-6-10 10 High Power Cylinder Series RHC Construction: 50 to 100 u q !2 i e !0 o w !6 !5 !4 !3 y r t !

n] Reverse output Page 46 [ tn_2] Set value (OUT2) 50% of maximum rated flow [ 50] 50 oC (for all ranges) Page 50 [ tH_2] Hysteresis (OUT2) 0% of maximum rated flow [ 5] 5 oC (for all ranges) Page 47 [ dtH2] Delay time setting at ON [ 0.00] 0.00 s Page 47 [ dtL2] Delay time setting at OFF [ 0.00] 0.00 s Page 47 [ CoL] Display colour (OUT2) [1SoG] ON: Green, OFF: Red (OUT2) Page 50 -32No.PF-OMV0006

or less HF: 5% or less HNO3: 5% or less c Hydrofluoric acid and Nitric acid mixture c Nitric acid (except fuming nitric acid) HNO3: 5% or less c Hydrochloric acid HC I: 5% or less 50 to 122F (10 to 50C) Note) HED007 50 to 86F (10 to 30C) p Note 2) Copper sulfate solution H2SO4: 96% or less 50 to 122F (10 to 50C) Note) HED007 50 to 86F (10 to 30C) p Note 2) Sulfuric acid (except fuming sulfuric

Spacer with Bracket (Z) G Center of F.R.L. body C BB (Y100T, Y200T only) E 1 X-X EE (Y100T, Y200T only) RELEASE X B 2 E X G Seal Y200T Y400T J F A H K Spacer width D Applicable model F 6.8 12 14 18 18 20 G 4.5 5.5 7 9 9 11 H 14 19 21 26 27 31 J 2.8 3.2 4 4 4.6 6.4 K 25 30 41 50 50 70 A 6 3 4 5 5 6 B 82 96 96 120 BB 56 67 C 24.5 29 41 48 48 60 D 40.5 53 68 81.5 86 112 E 20 24 35 40 40 50

Load weight Allowable moment E-MY2H/m3 E-MY2H/M3 E-MY2H/M1 E-MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 q r w et 20 20 20 20 Moment (Nm) Moment (Nm) Moment (Nm) Moment (Nm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 MY2H16 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300400500 1000 1500 100 200 300400500

Operate with a load ratio of 50% or less. If the load ratio exceeds 50%, this may cause problems such as failure of the lock to release, or damage to the lock unit. Bore size (mm) Stroke (mm) Bolt size Pulling force 5. Do not operate multiple cylinders in synchronization.

6 11 65 74 6 120 150 7 20 30 100 121 6 14 50 63 70.5 5 5 40 45 4.5 4.5 17.5 17.5 75.5 22 22 11 13 5 5 67 67 66 82 218 218 86 106 82.5 75.5 14 264 95 16 264 95 Other dimensions are the same as basic type.

Pedestal KZZ KL2 KY KS Pedestal 15 80 K 35 45 50 30 95 KL1 5 16 50 KC 15 KX 25 34 KZ 57 Material: Rolled steel Unit: mm K 40 50 KZZ 63 Option symbol Applicable clamp cylinder KC KL1 KL2 KS KX KY KZ Part no.

Operating Pressure 8 psi (0.06MPa) 8 psi (0.06MPa) 15 psi (0.1MPa) 40 to 140F (5 to 60C) 40 to 140F (5 to 60C) 40 to 140F (5 to 60C) Ambient and Fluid Temp. 2 to 20in/s 2 to 20in/s 2 to 20in/s Piston Speed (50 to 500mm/s) (50 to 500mm/s) (50 to 500mm/s) Basic , Foot Basic, Foot Basic, Foot Flange Front and Rear Flange Front and Rear Flange Mounting Side Tapped Side Tapped, Clevis Side Tapped

Mechanical end stopper (Extended end) (Retracted end) Mechanical end stopper Model A H Jnote) Connector side LAT3-10 10 10.5 5 Opposite side of the connector LAT3-20 20 20.5 5 LAT3-30 30 30.5 15 LAT3-50 50 70 25 Table stop position when returning to the Origin position in the retracted direction. Table stop position when returning to the sensor origin.

Rated voltage Note) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz Rated voltage Note) Coil insulation type Note) 1 2 3 4 5 6 7 8 J 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC Nil H Class B Class H DIN terminal and DC spec. are not available.

With feet and no rack mounting brackets With flow switch High-pressure pump mounted HECR 008-A 800 W 1.4 kW Tap water 0.01 to 0.03C Ethylene glycol 20% 010-A 1 kW 2 kW Single-phase 200 to 240 VAC (50/60 Hz) (UL Standards) Water-cooled Single-phase 100 to 240 VAC (50/60 Hz) New New HECR 008-W 800 W 1.4 kW Peltiertype watercooled 012-W 1.2 kW 2 kW Single-phase 200 to 240 VAC (50/

50 5 0 Z X Mass and center of gravity of the load 25 Center of gravity 50 Load no.

oC Detection method Thermal type Thermal type (main flow type) (branch flow type) range [L/min] Rated flow Dry air, N2, Ar 0.01 to 1 0.02 to 2 0.05 to 5 0.1 to 10 0.3 to 25 0.5 to 50 1 to 100 2 to 200 CO2 0.01 to 0.5 0.02 to 1 0.05 to 2.5 0.1 to 5 0.3 to 12.5 0.5 to 25 1 to 50 2 to 100 Instantaneous flow [L/min] -0.05 to -0.1 to -0.25 to -0.5 to -1.3 to -2.5 to -5 to -10 to Flow rate spec

14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 15 109 21 63 14 189 12 15 5 25 50 59.6 35 6 106.5 84 50 224 204 CG-E050SUS 15 109 21 80 22 234 14 23 6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 23 130 32 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 CG-E080SUS 258 23 131 32 Plug bolts are installed before shipment from factory.

M14 K 1.5 '5, 1->"14",5' 18 1M16xl.5 15 17 1M) Up to 1000 ' 50 47 157 126 160 281 17 36 ::1 36 ~~ 72 :.g;' 32 ' 71 43 15"" 'l7 15 20 160 Up to 1200 56 53 I 177 144 180 32 1'00 20 40 j~ 40 :g l 80 .2, 38 78.S 42 (mm) H Z ZZ f h , Bpre sige ' K K-A' 'L ' MM N P 5 U RR WithoUt ron-:bO'O't . ,.. ,', 'i":"WitH rod boot """ , ii' ', J!

Sensor 1 L/min 5 L/min 10 L/min 20 L/min 50 L/min 100 L/min 200 L/min 500 L/min Flow rate range 1 L/min 10 L/min PF2A510 0.5 L/min 10.5 L/min 5 L/min 50 L/min PF2A550 52.5 L/min 2.5 L/min 10 L/min 100 L/min PF2A511 105 L/min 5 L/min 20 L/min 200 L/min 210 L/min 10 L/min PF2A521 50 L/min 500 L/min 525 L/min 25 L/min PF2A551 Sensor Flow rate range Static Electricity

5 0 1 Hs 39 46 54 63 A 5 5 5.5 7 Hs 33 40 48 57 A 10 10 10.5 12 Size A 4.5 4.5 5 6.5 Hs 32 39 47 56 Hs 25 32 40 50 0.5 2 56.5 66 Operating range Minimum strokes for auto switch mounting (mm) (mm) D-A7H, D-A80H D-A79W D-F7, D-J79 D-F7W, D-J79W D-F7BAL, D-F7NTL D-F7F Bore size 25 Auto switch model D-A7 D-A80 D-A73C D-A80C 32 40 50 Number of auto switches D-P5DWL D-F7V D-J79C D-F7WV D-F7BAVL