H A B C H A B C 16 25 32 16 25 Rod flange: EQY H -F Head flange: EQY H -G LL FV M FV M FZ FX FT FX FZ 4 x FD FT 4 x FD The head flange type is not available for the EQY32.
9 l 16 2 x 4-J N F H + Stroke A K ZZ + 2 strokes S + Stroke H A K F N C B With rod boot In the case of w/o air cushion, it comes with rubber bumper.
+ Stroke S + Stroke H ZZ + 2 x Stroke BY BY Rod end nut 2 x BT BX BS + Stroke BX Rod end female thread D1 C1 H1 B1 MM MM (mm) d H1 B1 C1 D1 Part no.
Port Cushion valve Bore size (mm) Double clevis type/(D) Z ZZ CDH10 32 40 50, 63 80, 100 160 164 190 238 170.5 175 205 261 Double clevis type U Bore size (mm) Stroke range CDH10 CX +0.3 +0.1 CZ L RR U Z ZZ L Z + Stroke RR CX 32 40 50 63 80 100 to 500 to 500 to 600 to 600 to 750 to 750 23 23 30 30 42 42 10.5 11 15 15 23 23 13 13 17 17 26 26 28 28 40 40 60 60 154 158 182 182 228 228 164.5
9 l 16 2 x 4-J N F H + Stroke A K ZZ + 2 strokes S + Stroke H A K F N C B With rod boot In the case of w/o air cushion, it comes with rubber bumper.
point L (mm) H MHS MHZ2-10/11-MHZ2-10 MHZ2-32 60 MHC 150 50 Gripping point Pressure 0.2 MPa Pressure 0.2 MPa L MHT Overhang H (mm) Overhang H (mm) Pressure 0.2 MPa Pressure 0.2 MPa 40 0.6 MPa 0.6 MPa 100 0.3 MPa 0.4 MPa 0.5 MPa 0.3 MPa 0.3 MPa 0.3 MPa MHY 0.4 MPa 30 0.7 MPa 0.7 MPa The air gripper should be operated so that the workpiece gripping point L and the amount of overhang H stay
Internal Grip MHZ2, 11-MHZ2 MHZ2-6 MHZ2-25/11-MHZ2-25 40 100 Pressure 0.2 MPa Pressure 0.2 MPa 30 Overhang H (mm) Overhang H (mm) 80 H H 0.5 MPa 0.5 MPa Pressure 0.2 MPa Pressure 0.2 MPa 0.6 MPa 0.6 MPa 60 0.3MPa 0.3MPa 20 0.7 MPa 0.7 MPa 0.7 MPa 0.7 MPa 0.3 MPa 0.3 MPa 0.4 MPa 0.4 MPa Gripping point L 40 0.4 MPa 0.4 MPa 0.5 MPa 0.6 MPa 0.5 MPa 0.6 MPa 10 20 MHZAJ2, MHZJ2 0 20 40 60 80 100
1-phase 200V AC Lead wire end not Shared HRSE012-A-20/23-T (50/60Hz) 3 cores x 2.5mm2 treated with 100 V, 200 V HRSE018-A-20/23 (Bare cut) 15A 15A 30mA -23 Only (including HRSE018-A-20/23-T (L: Brown, N: Blue, PE:Green/Yellow) and 1-phase ground) HRSE024-A-20/23 230V 230V AC HRSE024-A-20/23-T (50/60Hz) HRSE Series 3.3 Installation 3-7 HRX-OM-R039 Chapter 3 Transport and Setting Up 3.3.3
5 to 16 Kit T NKE Corp.: Uni-wire System (16 output points) NKE Corp.: Uni-wire H System Note 1) Besides the above, F and P kits with different number of pins are available.
K Round head combination screw (Falling-out-prevention type) H Hexagon socket head cap screw (Falling-out-prevention type) !0 Manual override * For K and H, the valve body cover has a drop prevention construction to stop the mounting screws from falling out when the valve is removed for maintenance etc. * When ordering a valve individually, the base gasket is not included.
Nil R Internal pilot External pilot R U S Z NS NZ For K and H, mounting screws do not fall out from the valve.
G1/2 Water For Air For Medium R E C C R E A B1 A B1 Vacuum For Oil Construction Dimensions Construction Dimensions 2 x P 1 (IN), 2 (OUT) port 2 x P 1 (IN), 2 (OUT) port B B 2 x M5 Thread depth N 2 x M5 Thread depth N Terminal part Faston connector 250 Series 23 K K 11 9 6.5 J H H J 15 (mm) Conduit Faston type Dimensions Size Port size A B B1 C D E F P H J Q R Q R K N 1 1/8 1/8 1/4 3/8 1/
ECO F RUN MPa ALM PSI WRN LPM GPM Lighting up RUN MPa ALM M RMT WRN LPM H RUN EXT SEC RMT H AT SEC MENU RUN/ MENU RUN/ STOP STOP ENT Press and hold for approximately 1second.
Connector Socket Lead wire Hook 776 Compact Pressure Switch Series ZSE1/ISE1 Dimensions Grommet type: ZSE1-00-14/-15/-18/-19 Connector type: ZSE1-00-14C/-15C/-18C/-19C 4 . 23 4 . 23 Indicator light (Red) Indicator light (Red) 23 23 15 15 H HYS SET L H L H HYS SET L H Pressure setting trimmer Hysteresis setting trimmer Hysteresis setting trimmer Pressure setting trimmer 4 . 23 4 . 23 Indicator
With cap SR 6.8 8.7 12 18 25 B 6.5 9 12.5 16 21 A MM h M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 B 4 4 6 6 6 C 12 14 19 27 36 MM B M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 C h1 h2 d f RBC08C RBC10C RBC14C RBC20C RBC27C RB08J RB10J RB14J RB20J RB27J RB08S RB10S RB14S RB20S RB27S 6 7.5 10 20 25 12 14 19 27 36 13.9 16.2 21.9 31.2 41.6 6.5 8 11 16 22 23 23 31 40 51 9 11 15 23 32
With cap SR 6.8 8.7 12 18 25 B 6.5 9 12.5 16 21 A MM h M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 B 4 4 6 6 6 C 12 14 19 27 36 MM B M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 C h1 h2 d f RBC08C RBC10C RBC14C RBC20C RBC27C RB08J RB10J RB14J RB20J RB27J RB08S RB10S RB14S RB20S RB27S 6 7.5 10 20 25 12 14 19 27 36 13.9 16.2 21.9 31.2 41.6 6.5 8 11 16 22 23 23 31 40 51 9 11 15 23 32
Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.
molded 32A to 50A u Class H molded Coil assembly Class B molded i o u Coil assembly 17-3-38 7 Series VXD21/22/23 Pilot Operated 2 Port Solenoid Valve For Air, Gas, Water and Oil The VX series will be revised shortly.
With end lock Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Piston seal A A A CX2 R H R H CXW 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
6 40 80 87.2 57 9 144.5 120 80 291 257 CG-E080SUS 23 130 32 100 22 235 14 23 6 40 80 87.2 57 9 144.5 120 80 292 CG-E080SUS 258 23 131 32 Plug bolts are installed before shipment from factory.