Actuation Type: 2 Position Single Solenoid, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Negative Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor

Actuation Type: 2 Position Single Solenoid, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 12V DC, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Polar Type, Switch: None, Manual Override

Actuation Type: 3 Position Exhaust Center, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar Type, Switch: None

Actuation Type: 2 Position Single Solenoid, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar Type, Switch:

Actuation Type: 2 Position Double Solenoid, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar Type, Switch:

Actuation Type: Dual 3 Port Valve: N.C./N.C., Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Negative Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge

Actuation Type: 2 Position Single Solenoid, Pilot Specification: External Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar Type, Switch:

Actuation Type: 2 Position Double Solenoid, Pilot Specification: External Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar Type, Switch:

Actuation Type: 3 Position Closed Center, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Negative Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor

Actuation Type: 3 Position Closed Center, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Negative Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor

Actuation Type: 2 Position Single Solenoid, Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Non-plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Individual Wiring, Lead Wire Length 300 mm, Light, Surge Suppressor: Light/Surge Suppressor

Actuation Type: 2 Position Double Solenoid, Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar

Actuation Type: 3 Position Closed Center, Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar

Actuation Type: 2 Position Single Solenoid, Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Non-plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Individual Wiring, w/o Connector, Light, Surge Suppressor: Light/Surge Suppressor,

Actuation Type: 2 Position Single Solenoid, Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar

Actuation Type: 2 Position Single Solenoid, Flow: Standard Flow, Pilot Specification: External Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor: Light/Surge Suppressor, Non-polar

Actuation Type: Dual 3 Port Valve: N.C./N.C., Flow: Standard Flow, Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Coil Specification: Power Saving Circuit, Continuous Duty Type, Type: Plug-in, Rated Voltage: 24V DC; Use 24 V DC for EX180, EX510, and PC Wiring, Common Specifications: Negative Common, Connector Entry: Dedicated for Centralized Wiring, Light, Surge Suppressor

Actuation: Normally Closed, Coil Specification: Standard, Number of Solenoids: D [2pcs. (Double Solenoid)], Voltage: 24 VDC, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: U [with Light/Surge Voltage Suppressor, (Non-polar Type)], Switch: None, 2A/2B Fitting Port Size: ø2 One-touch Fitting, Straight Fitting, Metric

Actuation: Normally Closed, Coil Specification: Standard, Number of Solenoids: D [2pcs. (Double Solenoid)], Voltage: 24 VDC, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: Z [with Light/Surge Voltage Suppressor, (Polar Type)], Switch: w/Switch, 2A/2B Fitting Port Size: ø2 One-touch Fitting, Straight Fitting, Metric

Actuation: Normally Closed, Coil Specification: T [w/Power Saving Circuit (Continuous Duty Type)], Number of Solenoids: D [2pcs. (Double Solenoid)], Voltage: 24 VDC, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: Z [with Light/Surge Voltage Suppressor, (Polar Type)], Switch: None, 2A/2B Fitting Port Size: ø2 One-touch