SMC Corporation of America
Elite Part Number Search
Search Results "PF3A712H-N20-L3"

3.37 1.67 (7) (21) (54) (968) (55) (153.5) (70) (53) (23.5) (27.5) (48.5) (55) (35) (59) (85.5) (42.5) Dimensions by number of stations Model Symbol 2 3 4 5 6 7 8 9 10 NARM2500 L1 4.66 6.30 7.95 9.61 11.26 12.91 14.57 16.22 17.87 (118) (160) (202) (244) (286) (328) (370) (412) (454) L2 4.17 5.83 7.48 9.13 10.79 12.44 14.09 15.75 17.40 (106) (148) (190) (232) (274) (316) (358) (400) (442) L3

L3 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (120\ 5.35 (136) 5.98 (152) 6.61 (168) 7.24 (18/.\ 7.87 (2001 Millimtef in parentheses 53 C Single-Stage Nozzle (o1.5) . Produces high suction flow with quick response time. . Interchangeable with all other nozzleldiffuser ass'ys.

36 45 50 63 71 90 115 7 9 9 9 12 14 16 18 18 22 22 28 34 40 44 49 73 82.5 90 97.5 110 120 145 170 12 16 16 19 26 26 25 32 12 15 15 18 25 25 25 32 50 85 95 110 140 162 160 200 47 62 74 90 110 130 154 194 64 72 90 100 126 150 180 230 78 90 110 120 154 180 210 265 46 58 68 89 100 114 140 180 32 40 50 63 80 100 125 160 1.12-7 Series C92 Accessories Counter pivot E Bore (mm) R1 d2 CK S5 K1 K2 L3

V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070 VQ VKF Stations12345n D side U side VQZ 2-M5 x 0.8 (E port) VZ 2-M5 x 0.8 (P port) VS 43.5 A A VFN 20 (8.5) 1.5 5 (7.5) n-M5 x 0.8 (A port) 5 15 P = 10 38 n: Stations (Maximum

Unit n: Station L: Dimensions n L L1 L2 Equation L1=43n+64 L2=43n+76 L3 297 340 383 426 469 512 555 598 641 L3=43n+211 2 150 162 3 193 205 4 236 248 5 279 291 6 322 334 7 365 377 8 408 420 9 451 463 10 494 506 ( ): In case of direct manual override style.

M1 = F1 x L1 M2 = F2 x L2 M3 = F3 x L3 F2 F1 F3 LC6m LC6m L1 E-MY2C P.1127 L2 L3 E-MY2H LZm LZm P.1133 E-MY2HT LC3F2 LC3F2 Caution Xm Xm Select the required model by taking into consideration the operating condition specifications and any possible specification changes that may occur during operation.

V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070 VQ VKF Stations12345n D side U side VQZ 2-M5 x 0.8 (E port) VZ 2-M5 x 0.8 (P port) VS 43.5 A A VFN 20 (8.5) 1.5 5 (7.5) n-M5 x 0.8 (A port) 5 15 P = 10 38 n: Stations (Maximum

Body size Metric size 06 08 10 12 Inch size 07 09 11 13 3 4 5 6 1/8 1/4 3/8 1/2 6mm 8mm 10mm 12mm 1/4 5/16 3/8 1/2 Thread size Universal type 1/8 1/4 3/8 1/2 01 02 03 04 With One-touch fitting Uni-fit thread form Dimensions Models TUBE O.D. d L3 Applicable tubing O.D.

Description Material 1 Body SCS14A (SUS 316) 2 Needle SUS316 L4 3 Lock nut SUS316 4 Valve SUS316 5 Valve guide SUS316, NBR for low temperature L2 L3 6 Spring SUS316 7 Bolt SUS316 8 O-ring NBR for low temperature L5 9 O-ring NBR for low temperature Model Port size D H L1 L2 L3 L4 Note) L5 Mass g MAX. MIN.

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

32 6 20 32 8 66 103 50 96 19 6.6 25 5 40 20 6.6 19 42 66 54 36 17 46 8 5 40 6 25 32 8 66 110 50 99 23 6.6 25 5 40 24 6.6 23 42 66 54 40 17 46 8 5 40 6 ( ): In the case of air cushion. { }: In the case of auto switch. 6-11-19 6-11-19 Series C85 Accessory Dimensions [First angle projection] Single Knuckle Joint/DIN648-DIN24335 Double Knuckle Joint/ISO8140-DIN71752 d 45 d3 d7 d b1 b3 f l l3

L3 L4 L5 VF1000 VF3000 VF5000 34.5 60 95 4.2 4.2 3.45 33.4 59 89 5EA 1P L2 29.5 44.5 45.5 63.5 L5 L4 TRIAC Output Specification 2 For AC type valve, use this specification when the pilot valve is not recovered even though valve power supply is turned OFF at the equipment using output unit with large leakage voltage over 8% of the rated voltage (TRIAC output such as PLC or SSR, etc.).

L1 L2+A5 L3 Kinetic Energy 2 1 V 2 E = W () 2 1000 Collision speed V = 1.4 Va 1 420 2 E = x 1 () = 0.088 2 1000 Find the kinetic energy E (J) of the load. ) Correction factor (Reference values) V = 1.4 x 300 = 420 Ea = K E max Find the allowable kinetic energy Ea (J). Confirm that the kinetic energy of the load does not exceed the allowable kinetic energy.

When wires used for L11 and L21 are thinner than wires used for L1, and L3, use a molded-case circuit breaker. 11. Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the driver may cause a malfunction. 12. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience.

DC (Note 12) CN3 (Note 5) Forced stop 2 DOCOM DICOM 24 V DC (Note 12) Malfunction (Note 4) (Note 5) ALM CN8 RA1 (Note 9) Short-circuit connector (Packed with the servo amplifier) [1] Power supply input terminals, L1, L3: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).

Load weight (kg) m1 m2 m3 Moment (Nm) M1=F1 x L1 F1 F2 M3=F3 x L3 F3 M2=F2 x L2 L1 L2 L3 Maximum load weight 1. Maximum allowable load (1), static moment (2), and dynamic moment (at the time of acceleration/deceleration) (3) must be examined for the selection calculations.

N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119

Load (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

P=10.5 15.5 Station n L1 L2 3 52 44 Station 20 230.5 222.5 6 83.5 75.5 8 104.5 96.5 10 125.5 117.5 Station 2 41.5 33.5 4 62.5 54.5 5 73 65 7 94 86 9 115 107 11 136 128 12 146.5 138.5 13 157 149 14 167.5 159.5 15 178 170 16 188.5 180.5 17 199 191 18 209.5 201.5 19 220 212 12 Series SYJ300 Type 20R Manifold: Top Ported (External Pilot Type)/SS3YJ3-20RStations -00 [ ] for AC Grommet (G) L3

Separate cable IZT40-CF Shield wire Semi-stripped terminal Cable length L3 Cable specification Product No. L3(mm) Number of wire /size 12 cables/AWG20(4pcs. ), AWG(8pcs.) Nominal cross section 0.54mm2(4pcs.), 0.09mm2(8 pcs.) 0.96mm (4pcs. ), 0.38mm (8pcs. ) IZT40-CP3 2950 Conductor O.D.