Component Part Component Parts No. 1 Description Bracket Steel strip Material No. 1 2 3 Description Bracket Cross recessed round head screw Clasp Material Steel strip Steel wire Steel strip 617 AS Series Dimensions L7 L8 Lock nut L6 L5 Applicable tubing O.D. d D2 through D3 D4 L4 D1 L3 L2 M1 M1 L1 Metric Size MAX.
AS-FM AS-D AS-T ASP ASN AQ Dimensions ASV Universal type AK Applicable tubing O.D. d VCHC Applicable tubing O.D. d Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 (1) A (2) M1 Max. Min. Max. Min.
Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.
However, note that only the AS221FPQ uses steel. 713 AS-FPQ/FPG Series Dimensions H (Hexagon width across flats) Applicable tubing O.D. d A L4 D1 L3 D2 M1 L1 L2 T M5 type Applicable tubing O.D. d H (Hexagon width across flats) A L4 D1 L3 D2 M1 L1 T L2 Model Weight (g) (3) Tubing O.D. d T H D1 D2 L1 L2 L3 (4) M1 L4 (1) (4) Max. Min. Max. 1 2 Min.
2 Meter-out type Meter-in type 638 Speed Controller with Indicator/Elbow Type Uni Thread Type AS-FS Series Dimensions: Elbow Type Seal method: Gasket seal For Uni thread Indicator window direction: 0 Indicator window direction: 180 W1 X W2 Y D3 AS-F AS-F Applicable tubing O.D. d TMH ASD AS L3 A L4 D1 AS-FE KE AS-FG L2 L1 M1 AS-FP H (Width across flats) T AS-FM Metric Size [mm] Model d T H
KE AS-FG Dimensions AS-FP H1 AS-FM (Hexagon width across flats) AS-D Applicable tubing O.D. d AS-T H2 ASP (Hexagon width across flats) L4 L3 ASN L5 AQ ASV D1 L2 AK VCHC M M L1 ASR ASQ Metric Size Inch Size L4 Max. L5 (1) L5 (1) L4 Max. Weight (g) Weight (g) Panel-cut dimensions Panel-cut dimensions H1 H2 d D1 L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M Model Model Min. Max. 34.4 Min.
7 10 96 129 97 122 9 12 97 122 12 0.032 0.059 42.5 58.2 72.3 6-10-16 6-10-16 17 Series C76 Cylinder: Standard/Non-rotating Type Double Acting, Single/Double Rod Accessory Dimensions [First angle projection] Single Knuckle Joint/DIN648 Double Knuckle Joint/DIN71751 CJ1 CJP CJ2 CM2 CG1 MB (mm) (mm) MB1 Thread e M10 x 1.5 M12 x 1.75 b 10 12 d 40 48 f 10 12 g 18 23 c 20 24 j 12 15 a 20 24 0 l3
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB (mm) (mm) MB1 a 20 24 j 12 15 c 20 24 g 18 23 f 10 12 d 40 48 b 10 12 Thread e M10 x 1.5 M12 x 1.75 0 l3 14 16 Model GKM10-20A GKM12-24A Thread d3 M10 x 1.5 M12 x 1.75 h 43 50 d6 20 30 b3 b1 14 16 l 20 22 d7 19 22 Bore 32 40 Model KJ10DA KJ12DA Bore
L3 d1 H9 MB1 Part no. d3 h KJ27D KJ36D KJ42D M27 x 2 M36 x 2 M42 x 2 110 125 142 70 80 90 37 43 49 51 56 60 4 4 4 36 41 46 125 160/200 250 30 35 40 CA2 CS1 C76 C85 C95 CP95 NCM NCA D-X 20Data 6-12-39 40 Refer to Page 6-16-1 for details on auto switches.
Power cable L3 = 21 x m + 93 Brown: 24 VDC (for solenoid valves/output) White : 0 V (for solenoid valves/output) : The number of Input Blocks + The number of Output Blocks + The number of Power Blocks: m 2 1 5 24 VDC n,m L After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.
Separate cable IZT40-CF Shield wire Semi-stripped terminal Cable length L3 Cable specification Product No. L3(mm) Number of wire /size 12 cables/AWG20(4pcs. ), AWG(8pcs.) Nominal cross section 0.54mm2(4pcs.), 0.09mm2(8 pcs.) 0.96mm (4pcs. ), 0.38mm (8pcs. ) IZT40-CP3 2950 Conductor O.D.
HRLE050 200V N L HRLE090 200V L3 L1 L2 Fig. 3-12 Cable wiring (200V) 3.3 Installation Procedure HRLE Series 3-16 HRX-OM-Z002 Chapter 3 Transport and Set Up 400V L1 L2 L3 Fig. 3-13 Cable wiring (400V) HRLE Series 3.3Installation Procedure 3-17 HRX-OM-Z002 Chapter 3 Transport and Set Up 3.3.4 Preparation and wiring of communication cable Be sure to turn OFF the breaker of the facility power
Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.
M= WexL =5xVaxWxL 3 F3 L3
or knocking of stopper) V (m/s) : Impact speed (during locking or knocking of stopper) Va (m/s) : Average speed L (m) : Distance from C.G. of load M (Nm) : Maximum moment E (J) : Kinetic energy of load g (m/s) : Gravity acceleration (9.8m/s2) Load (N) W1 Moment (N.m) M1=F1x L1 F1
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
In-line Type Applicable tubing O.D. d Inch Size Metric Size Applicable tubing O.D. d Applicable tubing O.D. d Model Weight D1 D2 L1 L2 M1 L3 Max. Min. (g) Model Weight D1 D2 L1 L2 M1 L3 Max. Min.
L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max. Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33
592 537 482 427 372 317 262 207 152 L1 ARM3000 578 523 468 413 358 303 248 193 138 L2 550 495 440 385 330 275 220 165 110 L3 1.5-27 Regulator with Check Valve/Modular Style AR1000 to 6060 Standard Specifications AR1000 AR2060 AR2560 AR3060 AR4060 AR4060-06 AR5060 AR6060 Model AC 4 1/ / / / 4 1 4 1/ 8 1/ 4 3/ 8 3/ / 4 1/ M5 x 0.8 1 1 Port size 4 3 / 8 3 8 3 AV 2 1 Air Fluid AU 1.5MPa Proof