100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.
Auto switches are shipped together (not assembled). 92 Air Slide Table Series MXQ Specifications 6 8 12 16 20 25 Bore size (mm) M5 x 0.8 Rc 1/8, NPT 1/8, G 1/8 Piping port size Air Fluid Double acting Action 0.15 to 0.7 MPa Operating pressure MXH 1.05 MPa Proof pressure 10 to 60C Ambient and fluid temperature MXU 50 to 500 mm/s (Adjuster option/Metal stopper: 50 to 200 mm/s) Piston speed
To avoid this, indicate positions of manifold blocks for single wiring specification (S) and double wiring specification (D) on the manifold specification sheet. (Note that double, 3 or 4 position valves cannot be used for manifolds blocks with single wiring specification (S).) 1.
ZZ WL W V S RF P NB N MO 32 40 50 63 80 100 up to 500 up to 500 up to 600 up to 600 up to 750 up to 750 151 165 180 180 226 226 100 110 118 118 150 150 143 152 168 168 208 208 24 24 24 24 40 40 6.5 9 10.5 12 14 15 4 4 5 9 11.5 17 92 97 106 106 132 132 11 11 11 11 21 21 1/8 1/4 1/4 3/8 3/8 1/2 35 40 43.5 43.5 56 56 27 27 31.5 31.5 38 38 19 19 19 19 23 23 1.7-34 End Lock Series MBB With Mounting
Dispersion of the control system is not included. 100 Load 50% No load 50 500 1000 Amount of overrun Piston speed just before stop (mm/s) The graph above shows the relation between piston speed and overrun. (The length of overrun is changed, dependent on piston speed, load, piping conditions and control method.
Recommended shim thickness) Arm length L: 4 in 0.04 0.02 0.06 500 Clamping force (lbf) Peak clamping force position 400 0.7 MPa 300 0.5 MPa 0.3 MPa 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 50 Arm length L: 150 mm 2000 Clamping force (N) 1500 0.7 MPa 0.5 MPa 0.3 MPa 1000 500 0 0.5 0 1 1.5 2 3 4 5 6 7 8 9 Shim thickness (mm) (Ex. Recommended shim thickness) (Ex.
fluid temperature [C] Circulating fluid temperature [C] HRSE018-A-20/23-(T) [50 Hz] [60 Hz] 2000 2000 Ambient temperature Ambient temperature 25C Cooling capacity [W] Cooling capacity [W] 25C 1500 1500 35C 1000 1000 35C 500 500 40C 40C 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSE024-A-20/23-(T) [50 Hz] [60 Hz] 3000 3000 Ambient
Press the S button to set. Return to function selection mode.
Confirmation of allowable load weight by application Vertical upward: Lifter Vertical downward: Press Horizontal: Chucking L l m m F m F Maximum speed mm/s (in/s) Maximum speed mm/s (in/s) Load center of gravity position l mm (in) to 300 (11.8) to 500 (19.7) to 700 (27.6) to 300 (11.8) to 500 (19.7) to 100 (3.9) to 200 (7.9) to 300 (11.8) Graph Graph Graph Graph Graph Graph Graph Graph l
Maximum Speed: Up to 600 (mm/s) Graph (6) Maximum Speed: Up to 500 (mm/s) 0.3 30 40 50 0.2 20 10 0.1 2 3 4 5 Mass W (kg) Mass W (kg) 40 32 0.04 0.05 1 0.03 0.5 0.4 0.3 0.2 25 8 0.02 16 20 12 0.01 5 10 20 30 0.1 5 10 20 30 50 100 40 200 Overhang L (mm) Overhang L (mm) Graph (7) Maximum Speed: Up to 800 (mm/s) 30 40 50 20 10 2 3 4 5 Mass W (kg) 40 32 D1 0.5 0.4 0.3 0.2 -X 16 25 20 12 Individual
MXF With End Lock Specifications MXW MXJ MXS8 MXS12 MXS16 MXS20 MXS25 Model Bore size (mm) 8 12 16 20 25 MXP 50 to 500 mm/s Piston speed MXY Holding force (N) 25 60 110 160 250 Note) For caution on end lock, refer to page 86.
If it is a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 10min 14min 20min 30min 4min 6min 2min 1min 30 s Operating time 20 s 10 s 5 s Max. 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 600 5000 7000 Current (% for breaker capacity
40 200 Overhang L (mm) Overhang L (mm) Graph (7) Maximum Speed: Up to 800 (mm/s) 20 30 40 50 10 2 3 4 5 Weight W (kg) 40 32 1 0.5 0.4 0.3 0.2 16 25 20 12 0.1 50 100 200 5 20 30 40 10 Overhang L (mm) 8-10-6 6 Model Selection Series MTS Horizontal Mounting 8 Maximum speed: Up to 500 mm/s Maximum speed: Up to 300 mm/s Graph (8) Stroke: Up to 10 stroke Graph (11) Stroke: Up to 10 stroke 0.1
N.O. 0.4 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure (MPa) Flow Characteristics/Weight C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Effective area (mm2) Pilot port size Type of actuation Port size SYJA312-M3 SYJA322-M3 SYJA314-M5 0.41 0.18 0.086 0.35 0.33 0.086 Body ported N.C. N.O. N.C.
VDC Mega) between external terminal and case 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller. 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Note 1) In the case of PF2W711, 3% of F.S. or less (15C to 35C, based on 25C).
Note 10) Fixed unit: kPa Note 11) When K, Q, R or S is selected, select K for e Combination of Supply Valve and Release Valve.
How to Order Port Number q w e r KT10 L S 4PW 0 0 FV4 FV4 1 Delivery Pressure Delivery pressure Code 5 to 500 psig (0.034 to 3.4 MPa) 5 to 800 psig (0.034 to 5.5 MPa) 10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) Installation option Code Installation Bottom mount (Standard) Panel Installation F No code P H J Option Code Specification
Configuration One thermo-chiller for one controller. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.