Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200

However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8101 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 25 If the input current range

0 0 400 800 CS1 125 MB 100 600 300 Stroke (mm) AS5000-02 AS420-02 200 400 AS4000-04 200 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end (mm/s) Speed at the end (mm/s) Applicable related components Applicable related components

MB 50 10% 30% 70% 300 50% Stroke mm AS2201F -02-10 200 100 50% 30% 10% 70% 0 400 MB 63 300 Stroke mm AS3201F -03-10 200 100 0 ANA1 -C12 T1075 400 MB 80 300 Stroke mm AS4000-03 200 100 0 400 MB 100 300 Stroke mm 200 AS4000-04 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details

110 VAC [115 VAC] VFN 220 VAC [230 VAC] Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P B: Locking slotted type E: Push-turn locking

110 VAC [115 VAC] VFN 220 VAC [230 VAC] Electrical entry Manual override 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Nil: Non-locking push type D: Push-turn locking slotted type G: 300 mm lead wire L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire L P B: Locking slotted type E: Push-turn locking

100 50 500 200 100 400 300 0 Maximum speed [mm/s] Cylinder stroke [mm] Example) Load limit at rod end when the air cylinder 50 is actuated at 300 mm/s.

Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.

32.7 (32.8) AS221FS-02-08 (S) 8 13.2 23.9 33.2 (33.3) 14.2 24 (25) AS221FS-02-10 (S) 10 15.9 26.9 36.2 (36.3) 15.6 25 (26) AS321FS-02-06 (S) 6 1/4 17 (17.5) 13 13.3 10.4 21.8 32.1 36.4 63.1 61.7 57.9 56.5 24.5 28.5 9.3 19.2 47 (48) AS321FS-02-08 (S) 8 13.2 22.7 33 14.2 AS321FS-02-10 (S) 10 15.9 26.7 37 35.7 15.6 38 (39) AS321FS-02-12 (S) 12 18.5 29.7 40 34.5 17 50 (51) AS321FS-03-06 (S)

Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston speed (mm/s) Piston speed (mm/s) 40 40 500 500 50 400 400 63 300 300 200 200 100 100 1 0 1 2 3 4 5 6 0 0 1 2 3 4 5 6 7 8 9 10 7 Fully opened Without restrictor Without restrictor Fully opened Number of restrictors needle rotations Number of restrictors needle rotations

However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8001 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 24 If the input current range

(Pitch) 2n x M5 x 0.8 (A,B port) Built-in One-touch fitting: VV5K3-41Station -C4 Solenoid is at the same side as A port: VV5K3-S41Station (Pitch) Manual override (Non-locking) 2 x 4.5 (Mounting hole) (Pitch) VV061 2 x 4.5 (Mounting hole) Max.5 4 x Rc1/8 (P,R port) (Lead wire length) VV100 (Lead wire length) Manual override (Non-locking) V100 ~ = 300 ~ = 300 S070 VQD VQD-V 2n x M5 x 0.8 (

Workpiece table mounting Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Load mass: W = 1 [kg] L1 = 10 mm L2 = 30 mm L3 = 30 mm Enumerate the operating conditions considering the mounting position and workpiece configuration.

1600 kg mm/s mm 250 500 250 500 0.05 When axes are combined, select each axis considering the weight of the work piece and the body.

3 CQ2B16-T-PS CQ2B16-S-PS 16 CQ2B20-T-PS CQ2B20-S-PS 20 Port size Rc 1/8, 1/4 CQ2B25-T-PS CQ2B25-S-PS 25 Port size M5 x 0.8 Nickel plated 20 to 50, Anodized 32 to 50 CQ2B32-T-PS CQ2B32-S-PS 32 CQ2B40-T-PS CQ2B40-S-PS 40 CQ2B50-T-PS CQ2B50-S-PS 50 A set includes !4. Note Kits include items !4, !5, !

(See below) Bar length 300 300 mm 780 780 mm 1260 1260 mm Power supply cable is attached for all models. 1500 1500 mm 1900 1900 mm Bar length Number of bracket for body middle part 300, 780 Sensor 1260, 1500 1 S Mounted 1900 2 For [mounted], sensor cable and sensor bracket are attached.

magnet Number of auto switches Shaft type S W Single shaft Double shaft Nil S n 2 pcs. 1 pc. n pcs.

DIN rail for 9 stations J kit (Flat ribbon cable connector) S kit (Serial) kit F kit (D-sub connector) P kit (Flat ribbon cable connector) When changing the manifold style into a DIN rail mount Order brackets for mounting a DIN rail. (Refer to Option on page 2-4-24.) F 25P U S F 15P U S P 26P U S A S U S P 20P U S P 16P U S P A B C 10P J 20P U S Type No.