AR-OMY0028-A PRODUCT NAME Common Supply Regulator MODEL / Series / Product Number AR20M(K)-(F,N)(0101,0201,0202)(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,Y,Z,ZA)-D AR30M(K)-(F,N)(0202,0302)(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,Y,Z,ZA)-D AR40M(K)-(F,N)(0302,0303,0402,0403)(B,E,E1,E2,E3,E4,G,H,J,M)(-1,N,Y,Z,ZA)-D Contents Page 1. Safety Instructions 26 2. Application 7 3. Standard Specifications 7 4.
Option/Semi-standard symble:When more than one specification is required, indicate in alphanumeric order. 1 3 4 5 6 2 Symble Description 0.020.2MPa 0 0 0 0 Set pressure range 1 1 1 1 0.020.4MPa 2 2 2 2 0.020.8MPa + 1 Exhaust direction 0 0 0 0 Bottom exhaust + 2 Nil Nil Nil Nil Rc Pipe thread type NPT N N N N F F F F G + 3 Port size 01 01 01 01 1/8 + 4 Nil Nil Nil Nil Without pressure gauge
A port size Symbol Port size Exhaust style Individual exhaust Common exhaust 01 1 8
Model Model name IC AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 VBA G36-10-01 G46-10-02 Pressure gauge 1.0 MPa (5)(6) Accessory (Option)/Part No.
LVQ 1 (1.5 mm) 2 (2.2 mm) 3 (3 mm) 4 (4 mm) VXA31 VXA32 LQ 01 ( ) 1 8 02 ( ) 1 4 02 ( ) 1 4 03 ( ) 3 8 LVN TI/ TIL Ordering example (Example) Series VXA31, Orifice size 1.5 mm, Rc 1/8 (Part no.) VXA3114-01 PA PAX PB 17-3-103 8 The VX series will be revised shortly.
Option: Pressure gauge G15-10-01 How to Order NARM2000-4A2-N01G G15 P10 01 Symbol Units Nil MPa P PSI Common IN Individual IN IN M5 x 0.8 .39 (10) Max. pressure indication 10 150PSI (1.0MPa) .59 (15) IN OUT OUT *Pressure gauge for 30psig (0.2MPa) is not available.
Model Model name IC AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 VBA G36-10-01 G46-10-02 Pressure gauge 1.0 MPa (5)(6) Accessory (Option)/Part No.
G36-10-01) indicates thread. No symbol for "Rc(PT)" and "N" for "NPT". Consult SMC, if "NPT" gauge is required. Note 6) Piping adapter, O ring, Hexagon socket bolt, Hexagon socket bolt ass'y. These are shipped together with products. in the gauge part number indicates thread. No symbol for "Rc(PT)", "N" for "NPT" and "F" for "G(PF)".
Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.
(mm) A B C D E F G H J L Port size Bracket part no.
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 e OR-1400-178P P: PTFE F: FKM OR-2670-178P r P: PTFE F: FKM Wave washer For VCS30, 40 When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
Ionizer IZG10 08 01 01 Ionizer Gun One-touch fitting Nozzle type Symbol Applicable tube O.D.
(Only for EX510-S 01 ) -34No.EX-OMI0032-G No.
Example: In case of 6 stations of air suction filter ZFA100-01 ZZFA1-06 1 pc. (Brackets for 6 stations) ZFA100-01 6 pcs.
System Master unit: AFP3740 AFP5740 No. of output points, 16 points a) 2-wire type Wiring without signal ground line (SG) Master unit Slave unit 01 Slave unit 03 Slave unit 75 Master unit SI unit SI unit SI unit Master unit SI unit Twisted pair with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground b) 3-wire type Wiring with signal ground line (SG) Master unit Slave unit 01
LP-01 ML1C LC-01 25 32 40 Series Mounting position A B ML1C 177.5 128.5 152.5 123.5 147.5 172.5 D-M5 D-M5W D-M5T Lead wire cap Lead wire clamp Auto switch 14 11 Lead Wire Clamp/Lead Wire Cap (Option) 22 22 B A Lead wire clamp Lead wire cap Series LC-01 LP-01 ML1C (mm) 25 32 40 Mounting position Series A B 124.8 148.8 173.8 ML1C 113.2 137.2 162.2 Minimum Stroke for Auto Switch Mounting Operating
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" 38 (1.33) 7 (0.25) Flow rate l/min (ANR) (CFM) 12 (0.42) Controlled flow 0.6 (0.03) 0.2 (0.01) 0.1 (0.006) Effective area