SMC Corporation of America
Elite Part Number Search
Search Results "CVQB50-100-5M"

psi (0.7MPa) condition Inlet air temperature 100 oF (37.8oC) Ambient temperature 100 oF (37.8oC) Single phase Power supply voltage (Frequency) (Note 3) Single phase 230 VAC (60Hz) 115 VAC (60Hz) Max.

kPa 2.0 64 5 m 100 kPa 0.05mm 0.05mm [s] [s] [mm] [mm] 1.5 64 100 kPa 0.15 mm 2.0 64 100 kPa 0.3 mm [s] [s] [mm] [mm] -21No.PS-OMF0005CN-E ISA2-G ISA2-H 100 kPa 1.5 64 5 m 100 kPa 2.0 64 5 m [mm] [mm] [kPa] [kPa] -22No.PS-OMF0005CN-E ISA2 () 1 ON ( +)ON ()ON OFF Yes 2 No ( OFF +)ON 1 ()ON 3 ()ON 1,3 OFF 4 5 ON OFF 6 7 8 -23No.PS-OMF0005CN-E No.

Series CBQ2 Allowable Kinetic Energy Allowable Rod End Lateral Load 0.5MPa 0.4MPa With rubber bumper With auto switch (lateral resistance) 200 100 100 50 50 40 30 Allowable lateral load W (N) 63 20 Load weight kg 50 10 63 40 32 10 5 4 3 50 5 2 40 1 0 10 20 30 40 50 60 70 80 90 100 32 Stroke St (mm) 1 50 100 200 500 300 Maximum speed mm/s (Mounting orientation: Horizontal) W

In the case the wiring length to load is more than 5m. 3. In the case the load voltage is 100 or 200V AC. Be sure to use the contact protection box in any case mentioned above. Otherwise, the contact life may be shortened. (Due to permanent energizing conditions.)

Induction load Lead wire length greater than 5m (Standard model: 0.5m) 100VAC **In case of "D-B59W", red light illuminates at sensitive position and green illuminates at most sensitive position.

200 50 100 50mm/s 20 25 32 40 0 1.0 0 2.0 10 Time [s] Cylinder size [mm] 4.10-2 Series RHC low/medium speed opration with heavy loads 20 , 25 , 32 , 40 Cushion Ring MK/MK2 RSQ/RSG The long cushion ring can absorb larger energy (in terms of speed and weight).

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

Table 7-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70 or

The amount of grease per cylinder of 100 stroke is shown in attached table 4. Roughly, one scoop with a forefinger is approximately 3g.

(b11b0 cover 100%F.S.) The limit is 1332h, data of 120%, but the guaranteed accuracy is up to 100%F.S.

The amount of grease per cylinder of 100 stroke is shown in attached table 9. Roughly, one scoop with a forefinger is approximately 3g.

Mass* CRJB05-90 32 CRJB05-100 05 CRJB05-180 39 CRJB05-190 Basic type CRJB 1-90 54 CRJB 1-100 1 CRJB 1-180 67 CRJB 1-190 CRJU05-90 47 05 CRJU05-180 53 With external stopper CRJU1-90 70 1 CRJU1-180 81 *Mass of auto switch is not included. Effective torque Table 4.

Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110

Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3

Timing chart 100% 100% OFF OFF OFF Warning ON ON ON APH ASE Thrust SET O N 3 SET Input adjusted thrust OFF:100% thrust(Max.)