NPN open collector, single output Analog, no output, 3 turn setting 14 NPN open collector, single output Analog, no output, 200 degree setting 15 Electrical entry NPN open collector, double output Analog, no output, 3 turn setting 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 16 G H L LN LO M MN MO Lead wire length 300 mm Lead wire length 600 mm With lead wires (Length 300 mm) Without lead wires
(for Junction Common) Plug connector lead wires have a standard length of 300 mm, however, the following lengths are also available. Caution Single solenoid SJ3000-46-SC-l Double solenoid, 3 position type, 4 position type SJ3000-46-DC-l Connector Assembly Part No.
20 25 32 40 Bore size (mm) MK(2) 32 Piston speed (mm/s) 0.5 to 300 40 0.27 0.4 0.65 1.2 Allowable kinetic energy (J) RS Q G Note) Other intermediate strokes can be manufactured upon receipt of order.
Rubber bumper is standard equipment for long stroke type. 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Action 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 D Double acting 25 For "Manufacture of Intermediate Strokes", refer to page 7-4-5. Applicable Auto Switch/Refer to page 7-9-1 for further information on auto switches.
MGF40 MGF40 20MGF40 MGF40 10 10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100
g 300 g 300 g 1M12 (4 ) 2 3UL 050 -42No.EX-OMN0035CN-A (EX600-DYB) 0 1 2 3 2 Bit 1 Bit 3 Bit 5 Bit 7 4 Bit 0 Bit 2 Bit 4 Bit 6 (EX600-DYE) 1 2 3 4 5 6 7 8 0 2 4 6 8 10 12 14 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 14 15 16 17 18 19 20 21 1 3 5 7 9 11 13 15 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 (EX600-DYF) 0 1 2 3 4 5 6 7 2 Bit 0 Bit 2 Bit 4 Bit 6 Bit
(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series
Status (2): The temperature is in the "High/Low range, but no TEMP READY signal is generated since Ready Time is set at 300 sec at this point. Status (3): The 300 sec count for Ready Time is reset since the temperature is now outside of the Low range. Status (4): The 300 sec count for Ready Time starts since the temperature is now within the High/Low range.
Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.
However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8001 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 24 If the input current range
However, the lower limit (310) and the upper limit (320) setting cannot be established unless the following is satisfied. (300) Split range setting (320) (310) 40.0 % Example of connecting 2 units of IP8101 (unit 1 & unit 2) if (200)= (dir) is selected: 100% Unit 1 300=on 310=0.0 320=50.0 Stroke Unit 2 300=on 310=50.0 320=100.0 0% 0% 100% 50% Input current Fig. 25 If the input current range
4.95 5.99 6.85 7.70 8.55 50 MGPM50 3.36 4.00 4.73 5.37 6.01 6.65 7.29 7.93 9.54 10.8 12.1 13.4 63 MGPM63 4.18 4.94 5.78 6.54 7.29 8.05 8.80 9.56 11.4 12.9 14.4 15.9 80 MGPM80 6.49 7.43 8.67 9.61 10.5 11.5 12.4 13.4 15.8 17.7 19.5 21.4 100 MGPM100 10.5 11.9 13.6 14.9 16.3 17.6 18.9 20.2 23.6 26.2 28.9 31.5 (kg) MGPL12100/MGPA12100( (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300
Weight[kg] Series LEKFS25 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 S2 2.0 2.1 2.3 2.4 2.6 2.7 2.8 2.9 3.1 3.2 3.5 3.7 4.0 Motor type T6 2.1 2.2 2.4 2.5 2.7 2.8 2.9 3.0 3.2 3.3 3.6 3.8 4.1 Additional weight with lock [kg] 0.2 Series LEKFS32 Stroke [mm] 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 S3 3.4 3.6 3.8 4.0 4.3 4.5 4.7 4.9 5.1 5.3 5.8 6.2 6.6 7.1
) Actuator specification Horizontal Compact 10 to 200 20 to 350 Note4) Speed [mm/s] Note3) Note6) Vertical Basic 10 to 150 20 to 300 Note4) 10 to 150 20 to 300 Note4) Compact 10 to 150 20 to 300 Note4) Pushing speed [mm/s] Note5) 10 20 10 20 Acceleration / Deceleration [mm/ s2] 3000 Backlash [mm] 0.2 or less Positioning repeatability [mm] +/0.05 Lost motion [mm] Note7) 0.2 or less Impact
71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc(PT) 1/8 57.5 30 14 56 41 40 5.5 M6 x 1 Rc(PT) 1/8 64.5 30 14 62 49 50 6.6 M8 x 1.25 Rc(PT) 1/4 76.5 35 19 61.5 49 60 9 M10
100, 125, 150, 175, 200, 250, 300, 400, 500 32 131 90 27 16 45 49.5 64 M14 X 1.5 14 4.5 14 40 177 136 27 16 52 57 71.5 M14 X 1.5 24 5 14 50 63 200, 300, 500 193 144 32 20 64 71 85.5 M18 X 1.5 22.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 X 1.5 21 7 18 P T* X M N O Q Z L Bore size (mm) 32 40 50 63 Rc(PT) 1/8 57.5 41 34 5.5 M6 X 1 56 30 14 Rc(PT) 1/8 64.5 41 40 5.5 M6 X 1 62 30 14 Rc
(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic
Tube bore size B, #2(#2+#3) 40 125, 150, 175, 200, 250, 300 55 14 14 3.8-9 Series CXT Auto Switch Specifications Refer to p.5.3-2 for details on auto switch.
5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 MGF63 Load weight m0 (kg) Load weight m0 (kg) Load
Indicator light Standard Conforming to CE Standards Lead wire Oilproof heavy-duty vinyl cable, 6, 0.5 mm2, 2 cores, 300 mm Impact resistance Switch: 1000 m/s2, Connector: 300 m/s2 Insulation resistance 50 Mor more at 500 VDC Mega (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC529 standard