SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, ME, 40MM CQ2-Z DBL-ACT AUTO-SW, 1.34114 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PE, 63MM CQ2-Z DBL-ACT AUTO-SW, 1.84296 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, IE, 25MM CQ2-Z DBL-ACT AUTO-SW, .44337 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, FE, 12MM CQ2-Z DBL-ACT AUTO-SW, .22046 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, GE, 16MM CQ2-Z DBL-ACT AUTO-SW, .22046 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, LE, 32MM CQ2-Z DBL-ACT AUTO-SW, .63382 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, GE, 16MM CQ2-Z DBL-ACT AUTO-SW, .33069 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, HE, 20MM NCQ2-Z DBL-ACT AUTO-SW, .32230 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes *:
Magnet: D (Built-in), Mounting: R (Front Block), Bore Size: 106 (1 1/16"), Stroke: 0100 (1"), Cushion: C (Rubber Bumper), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, Lead Wire or Prewired Connector: L (3m)
(m) () AC 0.5( ) 1(M) 3(L) 5(Z) DC 3(NPN) M9NV M9N 3(PNP) M9PV M9P 2 12V M9BV M9B 5V12V IC 3(NPN) M9NWV M9NW 3(PNP) M9PWV P9PW 2 12V M9BWV M9BW IC 5V12V (2) PLC 24V 3(NPN) M9NAV M9NA 3(PNP) M9PAV M9PA 2 12V M9BAV M9PB (2) 2( ) P4DW IC 5V12V (2) (NPN) 5V A96V A96 IC 100V A93V A93 PLC 12V 24V 2 100V A90V A90 IC 18-2. 0.5m ) M9NW 1m M ( M9NWM D-P4DW32100 3m L (M9NWL 5m Z (M9NWZ
DC AC 0.5 1 3 5 () (M) (L) (Z) M9NV M9N IC 3 NPN 5V 3 PNP M9PV M9P 12V 2 12V M9BV M9B M9NWV M9NV IC 3 PNP M9PWV M9PW 3 NPN 5V 12V 2 2 12V M9BWV M9BW 24V M9NAV M9NA IC 3 PNP M9PAV M9PA PLC 3 NPN 5V 12V 2 2 12V M9BAV M9BA 2 2 P3DW 3 NPN A96V A96 IC 12V 100V A93V A93 2 24V 5V 100V A90V A90 IC PLC 12V 0.5m D-M9N M 1m D-M9NM L 3m D-M9NL Z 5m D-M9NZ 1 17 - 7-2. -1516
Supply Internal voltage Minimum operating > voltage drop of auto switch voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select an auto switch without an indicator for right (MODEL D-A90 , A90V)
Electrical entry Electrical entry WiringOutput Indicator Applied load 0.5 3 5 DC AC Vertical Horizontal Nil (L) (Z) 3 wires 5V A96V A96 IC circuit Equivalent to NPN Presense Grommet A93V A93 Relay 100V wires 24V PLC Nil 5V,12V 100V or less IC circuit A90V A90 24V 5V,12V M9NV M9N wiresNPN) M9PV M9P wires(PNP) 24V M9BV M9B wires Relay 24V PLC Grommet Presence 5V,12V F9NWV F9NW wiresNPN
Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less