t o o g e a n L c 2 s u s d Particulate generation has been reduced at the stroke ends by reducing impact using a sine cushion and by stopping the stroke using an internal stopper. i e Reduction of outgassing due to surface treatment n Impact acceleration [m/s2] o u d t R g g e a c 1 s u s d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless
Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
Enter together in order, counting from station 1 on the D side.
Enter together in order, counting from station 1 on the D side.
, 300, 400 Panel mount All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: N (w/o Cushion), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No