The section marked with diagonal lines becomes a cushion chamber, and a cushioning effect is achieved. A A' A' R H R H e When air is supplied for piston extension, the check seal opens and the piston starts with no delay.
Please contact SMC when the AC welding current exceeds 16000 A.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
Port size With One-touch fitting 01 M5 M5 R 1/8 R 1/4 R 3/8 R 1/2 02 03 04 Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
Centralized piping on right R R L L R L Slide table actuation direction Centralized piping on left R L L R R L Slide table actuation direction 2. The plug position of the piping port can be changed to suit the operating conditions. When screwing in the plug for the second time, wrap a sealant tape around the plug to prevent leakage. (1) M5 First tighten lightly until the rotation stops.
Shock absorber Port variations R L R L Tighten the four unit fixing bolts equally to secure the unit body. R R R R L L L L R L R L L R Slide table operating direction 8-14-26
Width across flats 1.5 H 13 (Plug: MGP12-08-CA001-R) 2 x M5 x 0.8 Piping port Width across flats 5.5 4 x M3 x 0.5 depth 4 6.5 16.4 M3 x 0.5 7 4 3.7 21 20 8.5 depth 2.5 3 4 x M4 x 0.7 A 0.5 19 +0.030 0 depth 2.5 3 20 0.05 Prepared hole diameter 3.3 +0.030 0 15 W 0.50.05 B D 2 x M5 x 0.8 Piping port M5 x 0.8 Vacuum port 28 27 10 4.5 J depth 1.5 3 6 +0.030 0 10 9.5 4 Section AA B D Mounting
C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23
C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23
x 0.8 depth 5 Piping port M5 x 0.8 depth 5 13 01: R 1/8 T1: NPTF 1/8 01: R 1/8 T1: NPTF 1/8 IF Data 16-6-13
(800) 526-7661 M5 x 0.8 Series Fibre Gasket Supplied 1/4 Hex Typ 35/64 35/64 29/64 29/64 .085 29/64 83 M5-B2 1/2 M5-B1 M5-B2 M5-B3 M5-B4 15/32 1/2 11 32 11 32 11 32 9/32 13/64 9/32 13/64 13/64 3 5/16 Hex Typ 84 M5-LB4 M5-LB1 M5-LB2 M5-LB3 M5-LB2 1/2 1 15/16 11/16 11/16 11/16 3 3 1/4 Hex Typ 5/16 Hex Typ 85 M5-T1 M5-T2 M5-T3 M5-T4 M5-T2 1/2 See complete selection of adapters on pages
A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A A A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System ADDRESS NO. STATION NO.
-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 A F MM F S + Stroke H ZZ + Stroke Bore size (mm) NN A P D MM F G1 G2 S ZZ I H J N1 N2 NA 10 M12 x 1 15 M5 x 0.8 4 M4 x 0.7 8 15 6 65 101 18.5 28 16 11 20 16 16 M14 x 1 15 M5 x 0.8 5 M5 x 0.8 10 15 6 74 114 22 30 22 12 21 19.5 20 M20 x 1.5 18 Rc 1/8 8 M8 x 1.25
6 r t !3 w q e RE A B REC CX CY !5 !0 !1 !2 u y i o MQQ M RHC MK(2) Material Note Component Parts RS Q G No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !
Note 2) Intermediate strokes are available as a special order. Data L R S Piping Port Locaition Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
(mm) At the minimum stroke of 25 mm adjustment bolt Basic stroke At maximum stroke adjustment At the minimum stroke of standard adjustment bolt Bore size (mm) Adjustment bolt fixing bolts Tightening torque Adjustment width across flats Bore size (mm) 10 15 25 10 15 25 A 2 A 26 A = 0.8 A = 0.6 A 0 4 M3 1.0 to 1.3Nm A 2 A 26 5 M5 4.6 to 6.2Nm Adjuster holder Adjuster holder A Adjustment bolt
GB Cushion needle 2-P (Hexagon socket head taper plug) 2-P (Hexagon socket head taper plug) 2-P 2-P (Hexagon socket head taper plug) 1 1 NE PP QQ XXSS RR SS H TT UU PH RW VV UU G A N T-slot for body mounting Z + stroke (mm) P M5 x 0.8 1/8 1/4 MM M4 x 0.7 M5 x 0.8 M6 x 1 L 80 110.8 180 LD 3.4 5.5 9 LB 50.4 71.7 80.3 LA 70 100 158 J M3 x 0.5 M5 x 0.8 M6 x 1 H 28 37 58 GB 17 19.5 31.5 G 8.5
When the pilot solenoid valve a is energized while the P1 port is under the pilot pressure, reduced pressure is supplied from the R port to the A port. The acting force of the pilot pressure (P1 port) reaches the space under the pressure control piston e pushes the piston upward and opens the poppet valve y. Thus air is supplied from the R port to the A port.
Dimensions inch (mm) AK3542 & 4542 M5 x 0.8 Actuation port 1.57 (40) 2.24 (57) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: N, BRN Connections: 4T, 6T Connections: 4, 6, BR 4 6 4 6 4 6 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70