L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +
30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the
size A C D E G H J 1(P) 2(A) 3(R) AV2000-m02-1 to 4G(Z)m-A 1/4 1/4 1/4 66 47 24.5 40 33 Width across flats 22 30 AV2000-m02-5 to 6G(Z)m-A AV3000-m03-1 to 4G(Z)m-A 3/8 3/8 3/8 76 50 29.5 40 38 Width across flats 24 35 AV3000-m03-5 to 6G(Z)m-A AV4000-m04-1 to 4G(Z)m-A 1/2 1/2 1/2 98 56 39.5 52 49 Width across flats 30 33 AV4000-m04-5 to 6G(Z)m-A AV5000-m06, 10-1 to 4G(Z)m-A 3/4, 1 3/4, 1 3/
Dimensions inside ( ) are for the model with brake. 130 2-8H10 depth 10 4-M8 x 1.25 thread depth 20 70 20 Work piece mounting reference plane 195 (225) 187 (217) 100 135 52 52.5 185 (215) 172 (202) 7.5 Stroke + 120 (table movement range) Stroke + 129 (table movement range) 29 33 92 2-T-slot 1 85 90 35 Stroke + 334 (364) 2-T-slot 2 90 62 3-8 H 10 depth 20 Stroke + 32 92 Body mounting reference
91) connection examples 3 wire NPN/AND connection 3 wire NPN/OR connection 2 wire 2 pcs-/AND conneclion 2 wire 2 pcsJOR conneclion o o When 2 swilches are connecied by ANO, load vollage willdecrease at ON and these connections may cause malfunction of load. Indication lights up when bolh swilches are ON.
2) Isopropyl alcohol Hydrochloric acid Ozone (dry) Hydrogen peroxide Concentration 5% or less, 50C or less Note 1, 2) Ethyl acetate Note 1, 2) Butyl acetate Note 2) Nitric acid (except fuming nitric acid) Concentration 10% or less DI water Sodium hydroxide Concentration 50% or less Nitrogen gas Super pure water Note 1, 2) Toluene Hydrofluoric acid Note 2) Sulfuric acid (except fuming sulfuric
Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.
x 2 x 6 H7 depth 8 2 x 6 H7 depth 10 NPT 1/8 G 2 x 2 x M6 x 1.0 depth 10 4 x M6 x 1.0 depth 10 NPT 1/8 G 52 52 198 B Power Clamp Cylinder Series CKZT Dimensions (Clamp Cylinder Without Arm) CKZT50, 63, 80 Release point XA CK1 CLK2 C(L)KQ MK2T/MK2/MK CKZ2N CKZT CLKZ1R CK/M(D)UKA RA XB RR XC Nh9 R NA0.02 NC RW LB For Asia For North America For Europe For France Special NB0.05 PD0.05 VC0.1 VB0.1
No.PF-OMM0004-D / / PF3W7## SMC 2 11 13 14 16 17 19 21 24 26 26 F1 OUT1 60 F2 OUT2 36 F3 42 F10 43 F20 47 F22 48 F30 50 F80 51 F81 52 F82 53 F90 54 F98 55 F99 56 57 61 61 65 65 71 79 81 88 -1No.PF-OMM0004-D (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
Problem Possible cause Investigation method Countermeasure (1)(2) Connect the (1) Check if the output current is 80 mA or more. appropriate load. (2) Check if the specified load is (3) Use a relay with a surge connected.
2 Label protector Cushion seal Urethane PET !
KGF12-04 18 24 52 Straight union: KGH Effective orifice(mm 2) Weight (g) Applicable tube O.D.
N.C. 1 N.C. 2 1 1 1 1 SD+ 3 2 2 2 2 SD4 3 3 3 3 N.C. 5 4 4 4 4 N.C. 6 N.C. 7 1 2 3 4 1 2 3 4 N.C. 8 CN4 CN4 No. No.
1 4 3 2 1 Sensor Sensor PF2D PF2D Load U CH_1OUT2 CH_1OUT2 White White IF Load Load 4 3 2 1 4 3 2 1 Sensor Sensor Sensor Sensor Sensor Sensor CH2_OUT1 CH2_OUT1 Gray Gray Main circuit Main circuit 24 VDC + 24 VDC + Load Load 4 3 2 1 4 3 2 1 CH3_OUT1 CH3_OUT1 Red Red Load Load CH4_OUT1 CH4_OUT1 Green Green 4 3 2 1 4 3 2 1 Load U DC() DC() Blue Blue 389 PF2D Series Functions/PF2D Refer to
VQ1 1 0 5 L Vacuum pressure switch ZQ1S D AS 31 C Solenoid valve VQ1 ZQ1 2 0 5 L Electrical entry Switch specifications Actuation Connector type 31 32 51 52 1 NPN output and analog output 2 NPN outputs 1 PNP output and analog output 2 PNP outputs 2 Normally open C Lead wire length: 0.6 m Connector type Pilot valve CL Lead wire length: 3 m Nil Standard type (1W) CN Without connector Rated