Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: M5 Female Thread, Option 1: -, Option 2: -
Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread)
Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: M5 Female Thread, Option 1: -, Option 2: -, Option 3: -
wire and case) 10 to 60C Ambient temperature Enclosure IEC60529 standard IP67 Lead Wire Lead wire length indication (Example) D-M9BW L Lead wire length Nil M L Z 0.5 m 1 m 3 m 5 m Note 1) 1 m (M): Available D-M9(V) only The D-M9M and M9VM (lead wire length: 1 m) will be available with products delivered from August 2008 onwards.
The theoretical output for extension is 1924N, from the theoretical output table on page 2. 20 Load mass m (kg) Load mass m (kg) 80 50 50 50 40 60 40 40 30 40 20 10 0 0 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Operating pressure P (MPa) Operating pressure P (MPa) Selection Graphs to (Horizontal Mounting) Graph l: 100mm or less Graph l: 101 to 200mm Graph l: 201 to 300mm
The kinetic energy of a load can be found using the following formula. 20 10 5 M 100 300 1000 2000 500 M 2 2 Ek = Maximum drive speed (mm/s) Ek: Kinetic energy (J) M: Weight of load (kg) : Piston speed (m/s) Example) Find the rod end load limit when a 63 air cylinder is operated at a maximum drive speed of 500mm/s.
0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 758 Cylinder with Lock Series CNS Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 500 1000 900 160 800 400 700 140 600 160 500 125 125 300 CLJ2 Load mass: m (kg) Load mass: m (kg) 400 140 CLM2 300 CLG1 125 200 CL1 200 MLGC CNG 100 500 400 300 200 100 100 500 400 300 200 100 MNB Maximum speed: V (
m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-8-6 7 Model Selection Series CNS Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 3000 3000 2000 2000 1000 1000 Load weight: m (kg) Load weight: m (kg) 160 700 800 900 700 800 900 CL 140 600 600 125 125 CL1 500 500 400 400 MLGC 160 300 300 140 CNG 125 200 200 MNB Courtesy of Steven Engineering
GB GA FA 4-J 4-FD Rc(PT) BP Unlocking port 2-Rc(PT) P Cylinder port GL GR G G Width across flats KA MM Q D EA E FY BF V FT VA AL A K F BN N N M C B FX FZ H S + Stroke ZZ + Stroke With rod boot 75 15 40 l h + l ZZ1 + l + Stroke Long strokes Rc(PT) BQ Plug with breathing hole BC element M GA T 4-J Width across flats KA 2-Rc(PT) P Cylinder port G G Rc(PT) BP Unlocking port GL GR GB 4-FD FA MM
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1581 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
G (Valve open) Pilot port Indicator (Option) (Back side P2) Bracket (Option) Main port Main port Rc A B C D E F G M N P Q R S T U Model 3 8 1 2 3 4 1 VND20D-10A VND20D-15A VND30D-20A VND40D-25A 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 80 90 50 60 35 40 17.5 20 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 61.5 74 17-4-40 5 Series VND Steam Valve: 2 Port Valve
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
Reducing type Reducing insert bushing 4 Series LQ1 Dimensions Male Connector: LQ1H-M Metric sizes M Connection threads R/NPT Model L H A M W E Applicable tubing O.D. 1/8 LQ1H11-M LQ1H12-M LQ1H21-M LQ1H22-M LQ1H23-M LQ1H24-M LQ1H31-M LQ1H32-M LQ1H33-M LQ1H34-M LQ1H35-M LQ1H36-M LQ1H41-M LQ1H42-M LQ1H43-M LQ1H44-M LQ1H51-M LQ1H52-M LQ1H53-M LQ1H54-M LQ1H61-M LQ1H62-M LQ1H63-M LQ1H64-M 4 3 6
Cable length (L) A1 (17.7) (10.2) 1 2 5 6 (14) (18) 1 3 5 8 A B C 1.5 m 3 m 5 m 8 m A6 B1 B3 A1 A3 B6 (13.5) 1 2 5.7 15 16 Connector B Connector D (30.7) L (11) (14.7) (10) 10 m LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C 15 m Actuator side Controller side 20 m 5.5 6.3 5.7 (14.2) Connector C (Terminal no.)
m For three phase 200 VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be
1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 100 100 63 63 50 50 Load mass m [kg] Load mass m [kg] 32 32 [Example] 50 50 40 40 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph m Graph v 0.5 MPa P 0.5 MPa P 1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 63 63 50 50 40 40 100 100 32 32 Load mass m [kg
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
Cable length (L) A1 (17.7) (10.2) 1 2 5 6 (14) (18) 1 3 5 8 A B C 1.5 m 3 m 5 m 8 m A6 B1 B3 A1 A3 B6 (13.5) 1 2 5.7 15 16 Connector B Connector D (30.7) L (11) (14.7) (10) 10 m LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C 15 m Actuator side Controller side 20 m 5.5 6.3 5.7 (14.2) Connector C (Terminal no.)