SMC Corporation of America
Elite Part Number Search
Search Results "12-REA32-700"

1 2 3 5 6 9 (1) 100 VAC (50/60 Hz) 200 VAC 110 VAC 24 VDC 12 VDC Other LQ Valve Type (A) 2 N.C.

For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively.

Yes A96V A96 Reed switch 5 V Grommet Relay, PLC 24 V 2-wire A93V A93 100 V 12 V 3-wire (NPN) M9NV M9N IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 2-wire 12 V Relay, PLC Yes Grommet 24 V Diagnostic indication 2-color indication F9NWV F9NW 3-wire (NPN) IC circuit 5 V 12 V 3-wire (PNP) F9PWV F9PW F9BWV F9BW 2-wire 12 V Notes) Solid state switches marked with a symbol are produced upon

(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output for display unit Output Note 2) specifications Environment Voltage output 1 to 5 V Accuracy: 5%F.S., Min. load impedance: 100 k (Output impedance: 1 k) Analog output Current output 4 to 20 mA Accuracy: 5%F.S., Max. load impedance: 300 or less (at 12 VDC), 600 or less (at 24 VDC) 12 to 24 VDC 10% Power

XLFV/With solenoid valve J M N Port P (pressure port) K L R P (mm) Port R (exhaust port) M 3 3 3 4 4 4 L 8.5 8.5 8.5 12 12 12 K 13 14 23 23 29 39 J 16.5 16.5 17.5 28 29 29 N Model XLFV-16 XLFV-25 XLFV-40 XLFV-50 XLFV-63 XLFV-80 3 3 3 2 2 2 Other dimensions are the same as XLF. 15 Series XLG, XLGV Double Acting/O-ring Seal Air Operated Type How to Order XLG 16 F9N High vacuum angle valve

V CY1H 12 V Solid state auto switch Reed auto switch Yes IC circuit CY1F CY1F 5 V, 12 V Relay, PLC Diagnostic indication (2-color indicator) Grommet 24 V 12 V CYP IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V IC circuit 3-wire (NPN equivalent) A96V A96 5 V 12 V Yes 24 V Grommet Relay, PLC A93V2 A93 A90 100 V 2-wire A90V IC circuit No 100

Analog output Current output 4 to 20 mA Linearity: 5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC 12 to 24 VDC (ripple 10% or less) Power supply voltage 20 mA or less Current consumption (No load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) Withstand voltage 1000 VAC for

(Refer to page 12.) 11 Multi-Axis Step Motor Controller JXC73/83/92/93 Series Wiring Example 1 For 4 Axes 1 pc.

Specification for Option V 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 How to perform maintenance . 12 2 12 4 Electric circuit . 12 2 Chapter 13 Service Record 13 1 Service Record . 13 1 Table of Contents 2 IDX-OM-W028 Air Dryer i Safety Instructions Safety Instructions Before use, read and comprehend important cautionary notification well on this operattion manual.

12 12 11.5 11.5 Operating range Note) Operating range Note) Perpendicular electrical entry is not available for 50 and 63.

IC circuit Reed switch Solid state switch A96 A96V 5 V Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) M9P M9PV 2-wire M9B M9BV 12 V Relay, PLC 3-wire (NPN) F9NW F9NWV 5 V, 12 V 24 V IC circuit Grommet Yes Diagnostic indication (2-color) 3-wire (PNP) F9PW F9PWV F9BW F9BWV 12 V 2-wire Water resistant (2-color) F9BA Although it

V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color display) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indication) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)

M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.

M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.

5.6.3 Key click sound setting . 5-12 5.6.4 Band width setting for the TEMP READY signal . 5-12 5.6.5 Setting of time for TEMP READY signal for out of range . 5-13 5.6.6 Anti-freezing function setting . 5-13 5.6.7 Fan output upper limit . 5-13 5.6.8 Electric conductivity function setting . 5-14 5.6.9 Reset the setting . 5-14 5.6.10 Reset of the accumulated operating time of the dust-proof

(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133

7 9.5 12 There is no difference in the frequency and the inrush and energized apparent power because a rectifying circuit is used in the AC (Class B, Builtin full-wave rectifier type).

(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133