Data 10-7-13 14 Rotary Clamp Cylinder: Heavy Duty Type Series MK2 20, 25, 32, 40, 50, 63 How to Order MK2 B S F9BW 20 10 R F Number of auto switches Nil S 2 pcs. 1 pc.
Other dimensions are the same as the grommet type. 3-7-12 13 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VZS2000 Non Plug-in 2 position double, 3 position closed center/exhaust center/pressure center Grommet 2 position double: VZS2250-G H(S)-01 3 position closed center: VZS2350-G H(S)-01 3 position exhaust center: VZS2450-G H(S)-01 3 position pressure center
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
speed mm/s Piston speed mm/s Piston speed mm/s 8-16-7 7 Series CY1F Vertical Actuation 1.
speed mm/s Piston speed mm/s Piston speed mm/s 8-16-7 7 Series CY1F Vertical Actuation 1.
I NA D J A F N2 N1 MM S + Stroke F H ZZ + Stroke (mm) P Bore size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18 M20 x 1.5 8 Rc 1/8 13 NPT 1/8 25 G 1/8 8.5 M8 x 1.25 97.5 151 31.5 40.5 28.5 20.5 33 29 25 M10 x 1.25 18 M26 x 1.5 10 Rc 1/8 13
RF S WB WL ZZ 40 50 63 80 100 up to 500 30 27 60 22 44 16 13 32 10 15 51 8 42.3 56 M8 x 1.25 6 14 11 M14 x 1.5 19 27 17 84 2.5 25 146 1/4 up to 600 35 32 70 27 52 20 13 40 12 17 58 11 47.3 61 M8 x 1.25 7 18 11 M18 x 1.5 19 30 17 90 2.5 25 159 3/8 up to 600 35 32 85 27 64 20 15.5 40 10 17 58 11 54.8 68.5 M10 x 1.25 7 18 14 M18 x 1.5 19 31 17 98 4 25 170 3/8 up to 750 40 37 32 78 25 52 14
Fig. 8.4-2 Cooling capacity(HRSE018-A-10) 8.4.3 HRSE012-A-20/23-(T) 1600 1600 Ambient Ambient Temperature Temperature 1400 1400 25 35 40 25 35 40 1200 1200 Cooling capacity[W] Cooling capacity[W] 1000 1000 800 800 600 600 400 400 200 200 0 0 0 10 20 30 40 0 10 20 30 40 Circurating fluid temperature[] Circurating fluid temperature[] 60Hz 50Hz The cooling capacity will be reduced by 100W when
Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ5140-01 Cylinder is in extending.
KQ2U23-M5 38 34.5 2.2 2.2 9 M5 X 0.8 10 9.6 41 44 9.6 15.5 37 38 14 3.4 2.9 3.2 1 8 KQ2U23-01S KQ2U23-02S 11 14 1 4 39.5 KQ2U04-M5 M5 X 0.8 M6 X 1.0 4 2.2 2.2 Kl KQ2U04-M6 40 36 10 11 10.4 16 4 10.4 1 8 42 38 KQ2U04-01S 4.2 4.2 11 Ml 1 4 KQ2U04-02S 46 40 20 14 42.5 KQ2U06-M5 M5 X 0.8 M6 X 1.0 2.2 2.2 12 KQ2U06-M6 43 39 13 Hl
To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.
kit 16 stations 16 NKE Corp.: Uni-wire H System 1 to 8 stations SUNX Corp.: S-LINK System (16 output points) 8 SUNX Corp.: S-LINK System (8 output points) 1 to 4 stations 8 stations D side DeviceNet, CompoBus/D (OMRON Corp.) 16 16 stations 1 to 8 stations OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) 8 8 stations 1 to 4 stations Mitsubishi
Configuration Minimum equipment and wiring requirements to get started Provided 1 Ex) 200 V AC (*1) by customer 5 6 Provided 1 by customer 7 2 3 (-) PC 1 2 (+) 8 4 C D 11 21 9 11 U 2 Electric Actuators Ex) LEF V W 3 Provided by customer 10 (Positioning unit/Motion controller) (*1)Refer to LECSS Operation Manual, Chapter 3 if the power supply voltage is 100VAC. 1 Driver LECSS*-S* 2 Motor cable
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.
A002 CKZ Arm 63 Arm code (Refer to page 3 and 8 through to 11.)
Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston speed (mm/s) Piston speed (mm/s) 40 40 500 500 50 400 400 63 300 300 200 200 100 100 1 0 1 2 3 4 5 6 0 0 1 2 3 4 5 6 7 8 9 10 7 Fully opened Without restrictor Without restrictor Fully opened Number of restrictors needle rotations Number of restrictors needle rotations
actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200
LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800
Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series