SMC Corporation of America
Elite Part Number Search
Search Results "VNB214AS-N10A-3G"

[Options] Controller communication cable(Part No: JXC-W2A-C) USB cable (Part No: LEC-W2-U) Teaching box (Part No: LEC-T1-3G) When connecting the teaching box to the JXCEH controller, the P5062-5 cable is required.

[Options] Controller communication cable(Part No: JXC-W2A-C) USB cable (Part No: LEC-W2-U) Teaching box (Part No: LEC-T1-3G) When connecting the teaching box to the JXC9H controller, the P5062-5 cable is required.

Part No: LEC-T1-3G 1. The above configuration is based on passing the CE marking exam. (For conformity standards, please refer to the declaration document on the SMC website.) 2. These items are included when ordered using the part number for an actuator set. 3. Latest version of the controller setting software must be used.

PLC Teaching box LEC-T1-3G DeviceNetTM Term inati Controller setting software Gateway unit LEC-W2 LEC-GDN1 LEC serial communication (RS485) Modbus communication Terminating Resistor Motor controller LEC Series Electric actuator LE Series 8 - 2. 4 Procedure How to start the actuator) Install, wire, set and operate the gateway unit referring to the procedure below when the product is used

Bracket C ZS-38-A3 Mounting screw (M3x5L, 2 pcs) Panel mount adapter ZS-27-C Mounting screw (M3x8L, 2 pcs) Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3x8L, 2 pcs) Front protective cover ZS-27-01 Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G

Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit

With rubber cushion Foot type (includes mounting bolt) Front flange type (includes mounting bolt) Rear flange type (includes mounting bolt) Double clevis type (includes pin, snap ring, bolt, and flat washer) 76 111 145 190 373 518 1064 1839 Calculation (example) CDLQD32-20DCM-B Basic weight: CLQA32-20D-. 453g Additional weight: Magnet. 64g Rod end male threads . 43g With rubber cushion .3g

For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types. 516 10-SYJ5000 5 port solenoid valve Series How to Order Light/Surge voltage suppressor Electrical entry for G, H, L, M, W Electrical entry for D Type of actuation Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch

For AC voltages add 3g to the weight of the single solenoid and 6g to the weight of the double solenoid and 3 position types. 495 4/5 port solenoid valve Series SYJ3000 How to Order Light/surge voltage suppressor Bracket Type of actuation Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar

Page 603-10 JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT Provided by customer (3 m) Communication cable To PWR Page 603-10 Power supply for controller 24 VDC Power supply plug (Accessory) Page 603-10 Options Teaching box Controller setting kit Conversion cable Note) Page 603-10 P5062-5 (0.3 m) Page 603-10 (With 3 m cable) LEC-T1-3G

Plug Barb elbow (H) 3.18/2.18 X M5 soft nylon Body rotates at 360 around the stud axis M-5E M-5ALHU-3 To plug unused M3 port polyurethane 3.18/2 X M5 P.2.1-51 M-3P Bulkhead reducer Reduction from Rc(PT)1/8 to M5 and includes panel mounting 4/2.5 X M5 6/4 X M5 soft nylon and polyurethane P.2.1-49 M-5ALHU-4 Rc(PT)1/8 X M5 female M-5ER Gasket M-5ALHU-6 P.2.1-50 To seal M3 thread P.2.1-52 M-3G

With bracket With light Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC Without DIN connector DIN terminal (With surge voltage suppressor) Enter symbols in the order below when ordering a combination of electrical option, other option, etc.

Option Teaching box Controller setting kit Teaching box (part number: LEC-T1-3G) Controller setting kit (part number: LEC-W2) [Controller setting software, communication cable, USB cable and conversion unit are included.] * In case of any shortages or damaged parts, please contact the selling office. (2) Installation Please refer to the 3.4 How to install (page 14) (3) Wiring and connection

DIN terminal (With surge voltage suppressor) VXD XL Lead wire length XL1 XL2 XL3 XL4 600 mm 1000 mm 1500 mm 3000 mm Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC DIN terminal (With surge voltage suppressor) Enter symbols in the order below when ordering a combination of electrical

Example Manifold Assembly Orders: Standard Configuration Manifold: Mixed Configuration Manifold: LINE ITEM DESCRIPTION LINE ITEM DESCRIPTION Four Station Manifold Ass'y as follOWS: Six Station Manifold Ass'y as follows: Sta. 1) NVFR31 OO-SFZ Sta. 2) NVFR3200-SFZ Sta. 1) NVFR2110-3G Sta. 2-6) NVFR2210-3G NWSFR2-10-06M-02T NARBF3000-00-P-1 WFS3000-20A-1 AXT636-1 A (P gallery) ) Mix: sta. 1)

Electric actuator *1) Prepared by user *6) I/O cable Part No: LEC-CN5PLC *3) *4) Power supply 24 VDC Controller to CN5 *1) *6) *6) Controller setting kit *2) *5) Actuator cable Part No: LE-CP--S Part No: LEC-W2 LE-CP--B-S to CN3 to CN4 (Standard cable) LE-CPLE-CP--B to CN2 (Robotic type cable) Teaching box to CN1 (with 3m cable) Part No: LEC-T1-3G *3) Power supply plug (accessory) Controller

DIN terminal (With surge voltage suppressor) Example) VX2 Z Z 1A 1 2 A Electrical option With light Other option Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC Without DIN connector DIN terminal (With surge voltage suppressor) Options marked with are available for Class H coil.

elbow (H) for soft tubing Plug M-5E Use to plug unused M3 port M-5ALHU-3 For polyurethane tubing 3.18/2 x M5 P. 59 M-3P Body rotates at 360 around the stud axis Reduction from Rc 1/8 to M5 including panel or bracket mounting Bulkhead reducer 4/2.5 x M5 6/4 x M5 P. 56 For soft nylon and polyurethane tubing M-5ALHU-4 1 8 Rc x M5 female M-5ER Gasket M-5ALHU-6 P. 57 To seal M3 thread P. 59 M-3G

Electric actuator *1) I/O cable Part No: LEC-CL5PLC Connect the ground *3) *4) Power supply for I/O signal 24 VDC Driver To CN5 *5) *1) *6) Communication cable for controller setting Actuator cable Part NoLE-CP--S Part No: LEC-W2A-C USB Cable To CN3 LE-CP--B-S To CN4 LEC-W2-U (Standard cable) *2) *5) LE-CPTo CN2 LE-CP--B (Robotic type cable) Teaching box (With 3m cable) To CN1 Part No: LEC-T1-3G

Electric actuator *1) *5) CC-Link Terminating Prepared by user resistance *6) PLC Communication plug connector *3) *4) LEC-CMJPower supply 24 VDC Controller to CN5 *1) *6) *6) Actuator cable Controller setting kit *2) *5) Part No: LE-CP--S Part NoLEC-W2 LE-CP--B-S to CN4 (Standard cable) to CN3 LE-CPLE-CP--B (Robotic type cable) to CN2 Teaching box to CN1 (With 3m cable) Part NoLEC-T1-3G