SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-AN-46-AS"

No, they cannot be used in open-air systems as the circulating fluids cannot physically circulate in such systems.
Refer to the water tank examples in the “Cooling Capacity Calculation” section in the HR□ catalog, and prepare an immersion type heat exchanger.

.· Can be used with -100‑kPa vacuum.Applications· Generally used in the same way as an elbow union. The difference is that the pipe is multi-layered and is used to prevent fitting interference.

.· Suitable for use in CRT production lines where contact with copper must be avoided, as well as cleaning of food processing machines where water or salt water splashes.· Suitable for use inside clean rooms where discoloration of copper materials and dust caused by corrosion must be avoided.Applications· Basically same applications as the Male Elbow.· Use to avoid the disruption of an extra

.· Suitable for use in CRT production lines where contact with copper must be avoided, as well as cleaning of food processing machines where water or salt water splashes.· Suitable for use inside clean rooms where discoloration of copper materials and dust caused by corrosion must be avoided.Applications· Basically same applications as the Male Elbow.· Use to avoid the disruption of an extra

The ZQ*A series can be used as a stand-alone generator, or as part of an ejector system or a vacuum pump system.  The ZQ*A not only offers a light weight, compact design (10mm body width, 70 g), but also includes options such as digital pressure switch with energy saving function.  Air comsumtion is reduced by 90%.

The ZQ*A series can be used as a stand-alone generator, or as part of an ejector system or a vacuum pump system.  The ZQ*A not only offers a light weight, compact design (10mm body width, 70 g), but also includes options such as digital pressure switch with energy saving function.  Air comsumtion is reduced by 90%.

40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.

ZSE20B(F) is a digital pressure sensor with an infomative, easy to read 3 screen, 3 color display.  The main screen shows the instantaneous reading in red or green, while two sub-screens can display the setting label and its numeric value in orange.  Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. 

ZSE20B(F) is a digital pressure sensor with an infomative, easy to read 3 screen, 3 color display.  The main screen shows the instantaneous reading in red or green, while two sub-screens can display the setting label and its numeric value in orange.  Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. 

ZSE20B(F) is a digital pressure sensor with an infomative, easy to read 3 screen, 3 color display.  The main screen shows the instantaneous reading in red or green, while two sub-screens can display the setting label and its numeric value in orange.  Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. 

Since the X port is an external pilot port, supply 0.25 to 0.7 MPa of compressed air. The PE port is an exhaust port for external pilot air. Air can be exhausted as is or by connecting a tube. When installing a silencer with a One-touch fitting, use a reducer fitting to increase the port size of the One-touch fitting. (Note: The valve will not switch if the PE port is plugged.)

An end lock cylinder is recommended. For bore sizes ø16 to ø100, a standard cylinder or a compact cylinder can be selected, so changes in external dimensions can be kept to a minimum. In general, the circuits and sequence programs can be used as is without making any changes.

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output.

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output.

Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.