Maximum operating pressure 10.7 MPa Minimum operating pressure Rubber bumper 0.12 MPa 0.06 MPa Air cushion 0.1 MPa CJ1 CJP Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C Cushion Rubber bumper Rubber bumper/Air cushion Lubrication Not required (Non-lube) Air cushion Rubber bumper Symbol CJ2 CJ2 JCM Piston speed Rubber bumper 50 to 750
VQZ3000 0.9 1.2 Bore size (mm) Cv Cylinder speed (mm/s) Series CJ2 Series CM2 Series CA1 Base mounted (With sub-plate) 6 10 16 20 25 32 40 40 50 63 80 100 150 300 V V VQZ1000 Body width 10 450 0.35 V V V 600 750 150 300 VQZ2000 Body width 15 0.7 450 V V V V V 600 750 150 300 VQZ3000 Body width 18 1.2 450 V V V V V 600 750 Cylinder speed marked with V can be controlled by speed controller.
130 40 37 32 100 50 25 82 11 9 28 20 71 13 89 M10 x 1.5 10 22 7 M22 x 1.5 80 3/8 210 100 to 750 110 10 131 40 37 41 125 60 30 100 14 10 29 20 71 16 M12 x 1.75 26 8 M26 x 1.5 100 1/2 212 Flange brackets and plug bolts are installed before shipment from factory.
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
20 ~ 750 37 40 102 78 25 52 14 21 21 M 12 x 1.75 11 17 M 22 x 1.5 37 1/2 116 0 100 ~ 750 20 ~ 750 37 40 116 92 30 52 14 21 21 M 12 x 1.75 11 17 M 26 x 1.5 40 1/2 126 0 With Gaiter Without Gaiter Bore (mm) ZZ ZZ H f h e l 146 154 40 51 15 59 65 167 50 15 66 58 75 159 178 15 66 75 63 1/4 Stroke 170 58 213 204 15 80 71 80 80 215 224 100 72 15 81 90 D I M E N S I O N S R E A R M A L E C L E
Positioning distance (mm) 1500 750 100 10 1 10 151.1 76.1 11.1 2.1 1.2 100 16.1 8.6 2.1 1.2 1.1 Speed (mm/s) 250 7.2 4.2 1.6 1.2 1.1 500 4.3 2.8 1.5 1.2 1.1 Values will vary slightly depending on the operating conditions.
AM150C AM250C AM350C AM450C AM550C AM650 AM850 Model Note) 300 750 1500 2200 3700 6000 12000 Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, 1 4 1 4, 3 8 3 8, 1 2 1 2, 3 4 3 4, 1 1, 1 1 2 1 2 1 2, 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Modular connection is possible with AM150C to 550C. (For details, refer to page 61.) Note) Max. flow at 0.7 MPa.
T dimension) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) Note) N.C. and N.O. common 30 10 (1 1/4B) 12 (1 1/2B) 16 (2B) 45 Note) The symbol Z indicates lengths other than the standard T length and adjustment range. Specify the T length in this case.
OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750
Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa (145psi) Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa (7psi) Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.
Motor output [W]/Size [mm] 750/80 Motor type AC servo motor200 VAC Encoder Absolute 22-bit encoderResolution4194304 p/rev Horizontal 135 Power consumption [W] *7 Vertical 150 Horizontal 15 Stnadby power consumption when operating [W] *8 Vertical 45 power [W] *9 Max.1100 Type *10 Non-magnetizing lock specifications 24 VDC Rated voltage [V] Power consumption at at20 [W] *11 Holding force [N
(140) () () Dimensions A Stroke Model B C D Note) LG1H202100-F LG1H202200-F LG1H202300-F LG1H202400-F LG1H202500-F LG1H202600-F LG1H202700-F LG1H202800-F LG1H202900-F LG1H202-1000-F LG1H202-1200-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500 50 150 250 350 450 550 650 750
PSE560 PSE561 PSE563 PSE564 Rated pressure range 0 to 1 MPa 0 to -101 kPa -100 to 100 kPa 0 to 500 kPa Extension analogue output range -0.1 to 0 MPa 10.1 to 0 kPa -50 to 0 kPa Withstand pressure 1.5 MPa 500 kPa 500 kPa 750 kPa Model No.
. -10 to +60o C with built-in magnet Ambient and fluid (No freezing) temperature Lubrication Not required (non-lube) +1.0 Stroke length tolerance 0 Cushion Rubber bumper Piston speed 50 to 750 mm/s 6 10 16 Allowable kinetic energy 0.012 J 0.035 J 0.090 J Use the actuator with allowable kinetic energy or less. Warning 1) Confirm the specifications.
The maximum speed of 750 mm/s can be accommodated if the piston is to be locked in the stationary state for the purpose of drop prevention. CLQ MLGP Made to Order Specifications (For details, refer to page 9-16-1.)