A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.93012 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EA, IT2000 3/8 INCPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV203------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, DB, IT1000 1/4 INCNPT VERSION, .55115 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV103------------
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE E136 7.22 INSTRUMENTATION ELECTRO-PNEUMATIC REGULATOR D I M E N S I O N S S E R I E S VY1D00-M5 D I M E N S I O N S S E R I E S VY1A0 0 1-M5 D I M E N S I O N S S E R I E S VY1B0 0 1M5 01 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !
Please contact us for the latest version.sales@ocaire.com, M5 PLUG, CONNECTORS, BRASS FITTINGS, 2X, BRASS FITTING NO SIZE
D I M E N S I O N S S E E N E X T P A G E NCDRB1BW30 P211180-1 NC_R1FW30 P211180-2 M O R E A C C E S S O R I E S S E E N E X T P A G E S E E I N S I D E F R O N T C O V E R F O R FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N350 DETAILS OF YOUR LOCAL SALES OFFICE 1.214 ROTARY ACTUATORS VANE TYPE SERIES NCRB1BW D I M E N S I O N S S E R I E S NCDRB1BW10~15 D I
type), A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, OTHER NO SIZE RATING, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, OTHER NO SIZE RATING, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, 0.19841 lb
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function. Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., OTHER NO SIZE RATING, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER
The ZSE40A(F) series is a high precision digital pressure switch, providing improved functions, performance and variations over the previous ISE40 series. Abnormal values can be seen at a glance on the 2-color display. The settings of the master pressure switch can be copied to up to 10 slave pressure switches, reducing the setting work, and preventing mistakes in setting. Other features
None Nil M5 x 0.8 NPT1/8 (With M5 female thread) N01 Bracket A Rc1/8, G1/8 A W1 Rc1/8 WF1 G1/8 Rc1/8, G1/8 Bracket B B M5 M5 x 0.8 (Female thread) M5 x 0.8 Bracket D C4 4 one-touch fitting D C6 6 one-touch fitting 4, 6 one-touch fitting Made to Order Panel mount adapter Combination of piping specifications with option 1 and part numbers of options 01 N01 W1 WF1 M5 C4 C6 Option 1 Description
1 14143 14144 14147 Stainless steel NBR 15-9-30 4 Speed Controller: Standard Type In-line Type Series AS Dimensions: AS1000-M3 Dimensions: AS1000-M5 Male M5 x 0.8 Female M5 x 0.8 Dimensions: AS2000/3000 Dimensions: AS4000 2-1/4 to 1/2 AS 2-port size ASP ASN AQ ASV Dimensions AK Max. Min.
lever type), A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw
type), A,B Port Size: Base Mounted Valve, Thread: Rc (or No Selection in the Case of M5 or One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw