SMC Corporation of America
Elite Part Number Search
Search Results "ANA1-12"

How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section

B 12 B 12 B 12 B 12 7 8 1 2 3 4 5 Valve stations EX600-ED4 1 set EX600-WEN1 1 set EX600-EU1 1 set SS5Y3-10S6WE72-05B-C6 (Type 10 5-station manifold base, Wireless EtherNet/IP) Negative common, M12 connector IN/OUT pin arrangement 1, I/O unit: 2 stations * SY3100-5U1 3 sets (2-position single part no.) * SY3200-5U1 2 sets (2-position double part no.) * EX600-DXPD 1 set I/O unit part no.

(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll

Communication connector D-sub 9 pin (socket) Holding screw: M2.6 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.

x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 250 x 4.186 x 103 x 12 900 = = 13953 [J/s] 14.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 14.0 [kW] x 1.2 = 1 x 250 x 60 x 1.0 x 103 x 12 15 x 860 16.8 [kW] = Thermo-chiller Q x t: Heat capacity [kJ] 13953 [W] = 14.0 [kW] Water bath 20C Cooling capacity = Considering

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

Note) Metric sizes 04 06 08 10 12 4 6 8 10 12 Elbow Control type 0 1 Meter-out Meter-in Note) For applicable tubing O.D. selection, refer to the Model on page 711.

(mm) GC F D BB A 10 16 15 15 15 18.3 12 18.3 14 20 4 5 8 8 5 5 11 11 CA GA BA CB GB 5 5 NN Z 82 83 54 55 M4 x 0.7 M5 x 0.8 S NB NDh8 20.5 20.5 9.5 9.5 10-0.022 0 MM Bore size H 28 28 17 20 NA M10 x 1.0 12-0.027 0 M12 x 1.0 With air cushion With air cushion type is not available for 21-/22-CJ2.

(Values at the initial period) Dustproof Solenoid Specifications Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz Electrical entry AC DC Rated voltage (V) Base mounted Allowable voltage fluctuation Inrush Holding Apparent power (AC) Diode (12 VDC or less: Varistor) Varistor 4.3 W (Standard), 2.3 W (Low wattage

XSA1 4.5 6 XSA2 7 8 XSA3 10.5 11.5 Reverse pressure potential 0.5 MPa(G)*1 Weight New New 18% *1 XSA1-12 (Refer to the Specifications on page 3.) 0.5 kg 0.41 kg lighter *1 Rated voltage *1 XSA2-2 32 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC 24 V, 12 V Applications Photovoltaic cell manufacturing Semiconductor manufacturing LCD manufacturing New New Female thread type (Rc,

(Aluminum: 6.5 g, Stainless steel: 17.6 g) ZNC30 to 80: The weight value is for the basic type without a plug. *6 For pressure sensor details, refer to the PSE540 series in the Web Catalog and the Operation Manual. 6 ZNC Series Lifting Force ZNC20m ZNC30m ZNC40m 12 16 6 14 10 5 12 8 Lifting force [N] Lifting force [N] Lifting force [N] 4 10 6 8 3 6 4 2 4 2 1 2 0 0 0 0 0.6 0.5 0.4 0.3 0.2

EX600-ZT1 (6)Assembled type connector PCA-1446553: For EtherNet/IPTM communication, M12 (4 pin) Plug, D code PCA-1578078: For power supply, 7/8 inch, Plug, Cable O.D. 12 to 14 mm PCA-1578081: For power supply, 7/8 inch, Socket, Cable O.D. 12 to 14 mm (7)Power supply cable PCA-1558810: Cable with 7/8 inch connector, Socket, Straight 2 m PCA-1558823: Cable with 7/8 inch connector, Socket, Straight

Check if there is a noise source An over current error (Er1 and 2) is indicated. (2)Check if the power supply voltage is in the range of 12 to 24 VDC. (2)Supply power voltage of 12 System error to 24 VDC.

KPa, kgf/cm2, bar, psi Temp. oC, oF 0 to 2100 L/min 0 to 1050 L/min Instantaneous flow 12 (Displays 0 when the value is below 20 L/min.) (Displays 0 when the value is below 10 L/min.)

MODE FUNC 5.4 Operation of Controller 5-12 A_HEC-OM-J004-4 Chapter 5 Operation [Tips] PV Indicator for unavailable change If a change in a parameter in the control mode (refer to page 5-12, 5.4.9 Details of Control Setting Mode) is attempted when 2 (RUN/READY setting) is selected, the indicator as shown on the left appears to show that the change is not available.

Additionally, note that the 12 VDC relay does not apply to the auto switch. -12- 11. Pay attention to leakage current. <2-wire type> Current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.

ID 0 1 2 1 063 1ABS() 3 1 ) 2INC() 4 H 2 065500 mm/s 5 L 6 3 7 2 4 2147483647 0.01mm 8 1 9 0 ID1 10 H 2 065500 mm/s2 11 L 12 H 2 065500 mm/s2 13 L 14 1 030 10% 15 1 030 10% 16 1 0255 mm/s 17 1 030 10% 18 H 2 065500 0.01mm 19 L ID2 2039 ID1 ID3 4059 ID1 ID4 6079 ID1 ID5 8099 ID1 ID6 100119 ID1 ID7 120139 ID1 ID8 140159 ID1 ) 0 12 36 - / Bit No.

Data writing mode.38 12. Memory map .39 12. 1 Memory assignment.39 12. 2 Controller IF status flagIN Data.43 12. 3 Gateway unit status flagIN Data.43 12. 4 Gateway unit control flagOUT Data.45 13. Precautions for controlling the controller (LEC).46 13. 1. Communication delay between the gateway unit unit and the controller(LEC) 46 13. 2.

Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions . 13 1 13 2 Specifications . 13 1 13 3 Remote operation . 13 1 13 4 How to connect the power and signal cable . 13 2 13 5 How to re-start the operation . 13 2 13 6 Electric circuit . 13 3 Chapter 14 Specification