Rated Flow Range: 20 to 2000 l/min, Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
This is a legacy product, and replaced byIDG30A-N02, AIR DRYER, MEMBRANE(300/75)-20, OTHERS, IDG MEMBRANE AIR DRYER, IDG 1/4 MEMBRANE AIR DRYER, 1.7196 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air temperature
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 09 [ø5/16 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4
for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket