Cover Tightening Torque Tightening torque(Nm) Bore size (mm) 32 40 50 63 80 100 12.5 1.2 74.5 7.4 100 10 411 41 Reassemble the cover with the above tightening torques. 204
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g, 125 to 160: 40 g). Order with the following part number when only the grease pack is needed.
Seal kit includes a grease pack (40 and 50: 10 g, 63 and 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed.
Cylinder with Lock/Double Acting, Double Rod Series CNA2W 40, 50 63, 80 100 Replacement Procedure is P.351 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Seal kit includes a grease pack (32 to 50: 10 g, 63 and 80: 20 g, 100: 30g). Order with the following part number when only the grease pack is needed.
Seal kit includes a grease pack (32 to 50: 10 g, 63 and 80: 20 g, 100: 30g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 157
Seal kit includes a grease pack (20 to 50: 10 g, 63, 80: 20 g). Order with the following part number when only the grease pack is needed.
Seal kit includes a grease pack (20 to 50: 10 g, 63, 80: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 139
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 35
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 15 is a non-replaceable part, so it is not included in the seal kit. 36
Self-diagnosis: 5% F.S. or less Switch output PNP open collector output: Max. 80 mA Hysteresis: 3% F.S.
Operate in an ambient humidity range between 45% to 80% (no condensation). 18 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Terminals SI Unit (EX600-SPRlA) EX600-SPR1A EX600-SPR2A Model Protocol PROFIBUS DP (DP-V0) Device type PROFIBUS DP Slave 9.6/19.2/45.45/93.75/187.5/500 kbps 1.5/3/6/12 Mbps Communication speed Configuration file GSD file I/O occupation area (Inputs/Outputs) Max. (512 inputs/512 outputs) Terminating resistor Internally implemented Internal current consumption (Power supply for Control/Input) 80
61.9 61.9 106.4 21.5 10 21.5 3B 3 1/2B M16 x 2 Thread depth 30 M16 x 2 Thread depth 30 280 145 140 273 210 80 120 130 78 78 130 20 5 20 4B Weight (kg) S T U V W X Model Threaded without flange With flange FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 23 M8 x 1.25 Thread depth 8 35 6 84 180 2.4 3.4 28 35 M8 x 1.25 Thread depth 8 50 8 91 240 3.6
70 60 50 40 30 20 10 0 1 5 10 50 100 100 90 80 100 90 80 70 60 50 40 30 20 10 0 100 200 300 400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration
Maximum allowable load current is 80 mA. Be sure to not exceed 80 mA. 1. Mounting orientation is available either horizontally or vertically. 2. Be sure to hold the main body when handling. 3. Do not drop or strike body. Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads.
override Push type/Locking type (Tool required) Vibration/Impact resistance Note 2) 30/150 m/s2 Protection structure Dust tight Coil rated voltage 12 VDC, 24 VDC Solenoid specifications Allowable voltage fluctuation 10% of rated voltage Coil insulation type Equivalent to class B 24 VDC 0.4 W DC (17 mA), 0.95 W DC (40 mA) Note 3) Power consumption (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80
Port size Exhaust cleaner for vacuum pump 10 14 20 30 40 R1 R1 R2 80 (3B) JIS 10K FF flange 1 2 Captures and separates 99.5% of even low-flow and highly concentrated greasy fumes. Using the AMV series, greasy fumes cannot be visibly recognized in the exhaust from the vacuum pump. (When greasy fumes are 1,000 mg/m3 at the IN side, it will be 5 mg/m3 or less at the OUT side.)
mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.