SMC Corporation of America
Elite Part Number Search
Search Results "DP-10"

" # $ % $& ' ($ % $& ) Input unit GW unit SI unit VQC1000 2000 4000 SI unit Input unit SV1000/2000/3000/4000 How to Order GW Unit GW Unit DN1 EX500 G Communication protocol DN1 PR1A MJ1 EN1 DeviceNet PROFIBUS DP CC-Link EtherNet/IP 1680

Available protocols include Profibus-DP, DeviceNet™, CC-Link, EtherCat and EtherNet/IP™. Protective structure: IP20; Operating temperature: -10 to 50° C; Operating humidity: 35 to 85%RH (no dew condensation); Acquired standard: CE marking; Weight: 160g

Available protocols include Profibus-DP, DeviceNet™, CC-Link, EtherCat and EtherNet/IP™. Protective structure: IP20; Operating temperature: -10 to 50° C; Operating humidity: 35 to 85%RH (no dew condensation); Acquired standard: CE marking; Weight: 160g

), Specification: Internal Pilot Specifications, Applicable valve: SV1000, P- and E-port entry position: D-side (2 to 10 stations), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 4

), Specification: Internal Pilot Specifications, Applicable valve: SV1000, P- and E-port entry position: U-side (2 to 10 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 6

pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV1000, P- and E-port entry position: U-side (2 to 10 series), Specified DIN rail length: Standard length, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 8

Type: Base for Manifolds, Communication Protocol: PROFIBUS DP Compatible, Output Format: PNP (Negative Common), Type: EX260 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 32 points (output), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting

Type: Base for Manifolds, Communication Protocol: PROFIBUS DP Compatible, Output Format: NPN Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: 4 points (input), Connector: M12 Connector, Mounting Method: Direct mounting, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting (P-

Type: Base for Manifolds, Communication Protocol: PROFIBUS DP Compatible, Output Format: PNP Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (without DIN rail), Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action pipe fitting (P-, E-Port)

;10 single-action pipe fitting (P-, E-Port), Specification: External Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: Both side (2 to 16 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 2

;10 single-action pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: Both side (2 to 16 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 4

;10 single-action pipe fitting (P-, E-Port), Specification: External Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: Both side (2 to 16 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 4

;10 single-action pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: Both side (2 to 16 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 6

;10 single-action pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: Both side (2 to 16 series), Specified DIN rail length: -, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 8

single-action pipe fitting (P-, E-Port), Specification: Internal Pilot Specifications, Applicable valve: SV2000, P- and E-port entry position: U-side (2 to 10 series), Specified DIN rail length: Standard length, Protective Structure: IP67 Specifications, Number of Input/Output Units: N/A, Number of Input Blocks: N/A, Number of Valves: 2

Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action

Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action

Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø4 single-action pipe fitting (A-, B-Port) / ø10 single-action

Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action

Type: Base for Manifolds, Communication Protocol: DeviceNet / PROFIBUS DP / Ethernet/IP Compatible, Output Format: NPN (Positive Common), Type: EX500 64 Points Compatible Cassette Base Manifold, Number of Inputs/Outputs: 16 points (output), Connector: N/A, Mounting Method: -, Port pipe connection port diameter: ø6 single-action pipe fitting (A-, B-Port) / ø10 single-action