DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.
tool stand sensor Air pressure port 6 x M3 x 0.5 Applicable shaft diameter d D Mass (g) Model Air pressure port 6 x M5 x 0.8 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 MA3 0-YNM5 MA3 0-YNM5-R1 MA3 0-YNM5-R2 MA3 0-YNM5-R3 MA3 0-YNM5-R4 MA3 0-YNM5-R5 MA3 0-YNM5-S6 MA3 0-YNM5-R6 MA3 0-AM3 MA3 0-AM5 440 Electrical contact points: 12 10 11 35 14 AHC unit 15 520 20 24 41 25 250 Tool adapter 270 750
Note 1 2 3 4 5 6 7 8 9 10 11 12 13 Zinc alloy Brass Electroless nickel plated Chromate plated Body A Body B Needle Seat ring Spring U seal O-ring O-ring O-ring Brass Electroless nickel plated Brass Electroless nickel plated Steel wire (1) HNBR NBR NBR NBR NBR PBT O-ring Bushing NBR, Stainless steel Tool steel Gasket Retaining ring for hole type C Note 1) M5 and U10/32 type: Stainless steel 750
Actuator lead (L = 6mm) Pulley ratio (n1/n2 = 1/1) 1 262144 1000 = = [PA06] [PA07] 1 6 1/1 262144 [PA06] [PA07] 1 6 1000 262144 [PA07] [PA06] = 6000 1 = 32768 [PA06] [PA07] 750 1 [PA06] = 32768 [PA07] = 750 *1 For pulley ratio, refer to Lead of LECSC Operation Manual (Simplified Edition),section 5.3.4.
Actuator lead (L = 6mm) Pulley ratio (n1/n2 = 1/1) 1 262144 1000 = = [PA06] [PA07] 1 6 1/1 262144 [PA06] [PA07] 1 6 1000 262144 [PA07] [PA06] = 6000 1 = 32768 [PA06] [PA07] 750 1 [PA06] = 32768 [PA07] = 750 *1 For pulley ratio, refer to Lead of LECSC2-T Operation Manual (Simplified Edition),section 5.3.4.
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
Bore size (mm) 32 40 50 63 80 100 125 l1 d2 CK S5 K1 G1 G2 EM CA H6 R1 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.5 1.5 51 11 10 6.6 38 10 21 7 18 26 31 32 8 10 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 15 12 9 50 65 12 33 11 30 32 45 45 12 12 67 15 16 9 52 14 37 11 35 40 50 50 12 15 86 18 16 11 66 18 47 12.5 40 50 60 63 14 15 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 20 25 14 94
Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs
Potential Amplitude Supply pressure: 0.3 MPa Applicable models: IZS40, IZS41 Applicable models: IZS42 1) With High speed static neutralization cartridge, For IZS40-1120, IZS41-1120 2) With High speed static neutralization cartridge, For IZS42-1120 200 2000 175 1750 Potential amplitude [V] Potential amplitude [V] 150 1500 V V 125 1250 0.1Hz 100 1000 1Hz 75 750 30Hz 30Hz 50 500 25 250 0 0 0
Process X+500 X+250 X (250 to 0) 250 (1000 to 751) (750 to 501) (500 to 251) data ISA3-H : The value in the brackets in level 2 shows the boundary value. -66No.PS-OMW0009-C 4 How to use X: Switch point is divided by weight.
Easy replacement of tube One-touch snap fit operation Tube stand Locked Unlocked condition Tube reel A movable reel support available. 600 mm 530 mm 750 mm Easy to move with casters.
75 [mm/s] 15 8 4 18 9 5 24 12 6 24 12 6 () [mm/s] 22 12 6 26 13 7 34 17 9 34 17 9 () 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20 12 6 [mm] 500 500 500 600 700 800 600 700 800 600 700 800 [mm/s] 500 250 1000 900 630 550 500 420 330 250 230 180 [mm/s] 10 5 20 12 6 () [mm/s] 17 9 33 20 10 () LEFS32 H A B [mm] 24 16 8 [mm] 600 700 800 900 1000 800 900 1000 800 900 1000 [mm/s] 1200 930 750
150 75 [mm/s] () 15 8 4 18 9 5 24 12 6 24 12 6 [mm/s] () 22 12 6 26 13 7 34 17 9 34 17 9 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20 12 6 [mm] 500 500 500 600 700 800 600 700 800 600 700 800 mm/s 500 250 1000 900 630 550 500 420 330 250 230 180 [mm/s] () 10 5 20 12 6 [mm/s] () 17 9 33 20 10 LEFS32 H A B [mm] 24 16 8 [mm] 600 700 800 900 1000 800 900 1000 800 900 1000 mm/s 1200 930 750
10 L/min 5 L/min 500 L/min PFMB7501 5 L/min 525 L/min 525 L/min 25 L/min 10 L/min 10 L/min 1000 L/min PFMB7102 1050 L/min 1050 L/min 50 L/min Rated flow range Set flow rate range Displayable range Flow Adjustment Valve Flow-rate Characteristics Analog Output PFMB7201 (for 200 L/min) Flow/Analog Output A B C 250 C Voltage output 1.04 V 1 V 5 V 300 kPa 200 Current output 4.16 mA 4 mA 20 mA 750
CB MB 32 45 48 6.5 6.6 9.5 5.5 32.5 45 26 22 5 12 30 10 26 40 52 56 6.5 6.6 12 5.5 38 51 28 25 5 15 35 12 28 MB1 50 60 64 8.5 9 12 6.5 46.5 64 32 27 5 15 40 12 32 63 70 75 8.5 9 16 6.5 56.5 74 40 32 5 20 45 16 40 CA2 80 90 95 11 11 16 10 72 94 50 36 5 20 45 16 50 CS1 100 110 60 115 12 11 20 10 55 20 89 41 5 25 113 60 C76 Mounting style (E) C85 C95 CP95 NCM NCA D-X 20Bore size (mm) d2 CK S5
0 500 1000 1500 2000 mm mm Installation distance [mm] Installation distance [mm] 3) With Energy saving high-efficiency cartridge 3) With Energy saving high-efficiency cartridge For IZT42-112V For IZT40-112VIZT41-112V 2000 200 1750 175 Discharge time [s] Discharge time [s] 1500 150 V V 1250 125 0.1Hz 1000 100 1Hz 750 75 30Hz 500 50 30Hz 250 25 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000
inlet Ventilation air outlet 715 40 or less 954 330 10 1538 A 1026 984 627 677 Anchor bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 330. 328 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Dimensions HRL300-Am-20 Ventilation air inlet Ventilation air inlet Ventilation air outlet 850 40 or less 1079 330 10 1839 A 1145 1109 700 750
100, 200, 300, 400, 500, 600 200, 300, 400, 500, 600, 700, 800 63 100 160 Specifications Operating pressure 0 to 0.7 MPa Proof pressure 1.05 MPa 5 to 50C Ambient and fluid temperature Fluid Turbine oil (40 to 100 mm2/s) Converter Standard Effective Oil Level Stroke/Effective Volume (cm3) Converter nominal size (mm) Limited flow (dm3/min) Standard effective oil level stroke (mm) 100 300 750
, 300, 400, 500, 600 200, 300, 400, 500, 600, 700, 800 63 100 160 Specifications Operating pressure 0 to 0.7 MPa Proof pressure 1.05 MPa 5 to 50C Ambient and fluid temperature Turbine oil (40 to 100 mm2/s) Fluid Converter Standard Effective Oil Level Stroke/Effective Volume (cm3) Converter nominal size (mm) Limited flow (dm3/min) Standard effective oil level stroke (mm) 50 150 100 300 750
150 300 450 600 750 150 300 450 600 750 150 300 450 600 750 SY3140 -01 Cv = 0.3 SY5140 -02 Cv=0.7 SY7140 -03 Cv = 1.2 SY9140 -04 Cv = 2.8 The speed of CJ2 and CM2 cylinders is controlled by a fixed orifice built into the cylinder.