Device Signal name Signal status AXIS AXIS AXIS AXIS 1 2 3 4 PLC READY signal ON PLC CPU preparation Y0 QD75 READY signal ON QD75MH preparation X0 All axis servo ON ON All axis servo ON Y1 Interface signal Synchronization flag(Note1) ON QD75MH buffer memory Accessible X1 Axis stop signal OFF Axis stop signal is OFF Y4 Y5 Y6 Y7 M code ON signal OFF M code ON signal is OFF X4 X5 X6 X7 Error
This connection example complies with the requirement of ISO/EN ISO 13849-1 category 3 PL d. 24 V EMG S4 S3 KM1 S2 KM1 Fuse K3 +24 V XS0 XS1 Z00 Z10 Z20 KM1 Safety relay module MELSEC (QS90SR2S) Power supply Control circuit KM1 Driver Servo amplifier X0 COM0 24G X1 COM1 Z01 Z11 Z21 CN8 Control circuit STO1 S1 or EMG (Note) EMG STO2 STOCOM K3 TOFB1 TOFCOM 0 V TOFB2 20 S1: STO shut-off switch
Device Signal name Signal status QD77MS2, QD77MS4 QD77MS16 PLC READY signal ON PLC CPU preparation Y0 QD77MS READY signal ON QD77MS preparation X0 All axis servo ON ON All axis servo ON Y1 Synchronization flag(Note1) ON QD77MS buffer memory Accessible X1 Interface signal Axis stop signal OFF Axis stop signal is OFF Y4Y7 [Cd.180] Axis stop M code ON signal OFF M code ON signal is OFF X4X7
Front view Mounting holes on the top Mounting holes Theread size Name Type Mounting hole Main body M5 Side Support A Mounting hole M5 Side Support B Mounting Tap M6 x1 Side support A Side support B MY-S25A MY-S25B Mounting holes Mounting taps Installation of work Use 4 threaded holes on the top of slider for installation of work.
LATH3LAT3MLAT3FEncoder resolution (m) 30 5 5 2.5 1.25 Note 1) Connected model MANUAL Multiplier factor X4 X4 X1 X2 X4 Value per 1 pulse 00.0300 00.0050 00.0050 00.0025 0.00125 Decimal point position Input type 2PHASE Note 1) Since the CEU5 Multi-counter has a 6-digit display, the tens of digits will not be displayed when the resolution is set to 1.25.
LATH3LAT3MLAT3F30 5 5 2.5 1.25 Note 1) Encoder resolution (m) Connected model MANUAL Multiplier factor X4 X4 X1 X2 X4 Value per 1 pulse 00.0300 00.0050 00.0050 00.0025 0.00125 Decimal point position Input type 2PHASE Note 1) Since the CEU5 Multi-counter has a 6-digit display, the tens of digits will not be displayed when the resolution is set to 1.25.
Reference 6.4 Electric wiring diagram [IDF100/125F/150F-30-W] For Option R GFCI PE TB1 THR MC1 CM OLR MC1 HM PRR SWL PLC TB2 Y0 1 MC1 Operation COM0 2 Y3 3 Failure COM3 4 MC1 Y1 X4 5 Remote control PRR COM1 X0 6 THR X1 PRS2 PRS3 X3 P P L N 24V EDV PE Symbol Description CM Refrigerating compressor For Option V OLR Overload relay MC1 Magnetic contactor THR Thermal relay TB1,2 Terminal block
80A 10K 64 (17) 17) 40 (K16K) 1823) (18~23) JIS 80A 10K 479 127 1332 1432 1,3 -W4 (-W4) -W4 Y3/4 (-W4) Y 3/4 () () R3/4 R3/4 20 50 165 475 9902 1030 950 (-W5) -W5 1,3 (-W5) -W5 R3/4 R3/4 IDF100F150F-W 6 5 IDX-OM-Z004 6 6.4 IDF100/125F/150F-30-W R R GFCI PE TB1 THR MC1 CM OLR MC1 HM PRR SWL PLC TB2 Y0 1 MC1 COM0 2 Y3 3 COM3 4 MC1 Y1 X4 5 () PRR () COM1 X0 6 THR X1
: ON 3 Input block connector Connects the Input block. 12 8 Output block connector Connects the solenoid valve, Output block etc. 4 SW 1 5 13 9 Safety Instructions SI unit 5 Display window LED display shows the SI unit status. 2 6 14 10 HW 6 Switch protective cover Sets the address etc. with the switch inside. 31 29 27 25 23 17 3 7 21 19 15 11 Address setting mode change over switch x10 x1
Station number setting Setting Setting range x10 0 to 6 x1 0 to 9 : The station number should be set within the range of 01 to 64. If the number is set to 00, or to 65 or above, the L ERR LED will turn on. : The station number must not be duplicated, this will cause an error. : The default setting is 00.
Designation Description 3 Setting the Number of occupied stations Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 5-pin plug, B-coded) 3 1 SV24 V +24 V for solenoid valve Setting Station No. 4 5 2 2 SV0 V 0 V for solenoid valve x10 x1 4 Ground terminal Functional earth (M3 screw) 3 SI24 V +24 V for SI unit operation 0 0 Error (Default
OFF ON ON ON ON ON -20No.EX-OMN0034-B Station setting switch: Set the station number of SI unit Station number setting Address Station number x10 x1 0 0 Error (Default setting) 0 1 1 0 2 2 : : : 6 3 63 6 4 64 6 5 Error : : 9 9 : If a station number is set to 00 or over 65, the "LERR" LED will light up. The settable range depends on the number of occupied stations.
This is a legacy product, and replaced byVHS50-06B-X1, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, LA, VHS BODY PT >3/4, 1.90695 lb
Please contact us for the latest version.sales@ocaire.com, ROD COVER ASSY, ACTUATOR, CS1/CS2 TIE ROD CYLINDER, X1, 200MM CS1 PART, 29.04000 lb
Please contact us for the latest version.sales@ocaire.com, TIE ROD, ACTUATOR, CS1/CS2 TIE ROD CYLINDER, X1, 200MM CS1 PART, .00000 lb
Please contact us for the latest version.sales@ocaire.com, PIVOT PIN, ACTUATOR, NCA1 TIE-ROD CYLINDER, X1, 8 INCH NCA1 PART, .00000 lb
Please contact us for the latest version.sales@ocaire.com, ASSY, PISTON ROD, ACTUATOR, NCA1 TIE-ROD CYLINDER, X1, 8 INCH NCA1 PART, .00000 lb
Please contact us for the latest version.sales@ocaire.com, ASSY, PISTON ROD, ACTUATOR, NCA1 TIE-ROD CYLINDER, X1, 8 INCH NCA1 PART, .00000 lb
Please contact us for the latest version.sales@ocaire.com, ASSY, PISTON ROD (CANADA), ACTUATOR, NCA1 TIE-ROD CYLINDER, X1, 8 INCH NCA1 PART, .00000 lb