KF series: -101.3 kPa to 1 MPa
KQ2, KQG2, KQB2, KP, KS, and KX series: -100 kPa to 1 MPa
Z□ series vacuum ejector: -80 kPa to -91 kPa

Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated; Material for actuator section: PVDF resin, Body: new PFA; Connection type: tube extensions; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated; Material for actuator section: PVDF resin, body: new PFA; Connection type: LQ3 flare (Z), integral fittings ; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Manually Operated; Material for actuator section: PVDF resin; Body: New PFA; Connection: flare integral fittings; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated ; Material for actuator section: PVDF resin, Body: PFA ; Connection type: Insert bushing, integral fittings (V) ; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Manually operated; Material for actuator section: PVDF resin, Body: new PFA; Connection type: insert bushing, integral fittings; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated ; Material for actuator section: PVDF resin, Body: PFA ; Connection type: Insert bushing, integral fittings (V) ; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated; Material for actuator section: PVDF resin, body: new PFA; Connection type: LQ3 flare (Z), integral fittings ; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Air operated; Material for actuator section: PVDF resin, Body: new PFA; Connection type: tube extensions; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Manually Operated; Material for actuator section: PVDF resin; Body: New PFA; Connection: flare integral fittings; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Manually operated; Material for actuator section: PVDF resin, Body: new PFA; Connection type: insert bushing, integral fittings; Orifice diameter: 4 to 22mm

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). Manually operated ; Material for actuator section: PVDF resin, Body: new PFA ; Connection type: tube extensions ; Orifice diameter: 4 to 22mm

Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). High purity, compact type with integral fittings; Mounting base dimensions conform to SEMI standard F65-1101 (Except for LVD10); New PFA body; Piping from 4 directions are possible; Variety of tubing sizes available  

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). High purity, compact type with tube extensions; New PFA body; Piping from 4 directions are possible; Variety of tubing sizes available; Dimension across inlet/outlet ports: Reduced by up to 29% compared to the LVC series

The LVD valves have PFA body materials and integral fittings (Hyper Fitting series LQ1 and clean series KP). High purity, suck back type with integral fittings ; Tubing O.D. available in metric and inch sizes  ; Orifice diameter: ø2  ; Cv: 0.09  ; Operating pressure: 0 to 0.2MPa  

Nut Insert bushing Nut Insert bushing Nut Insert bushing LQ1T2A-ST1 2 2-07 LQ1-2N07 LQ1-2B07 Applicable body size 2 2-07 LQ1-2N07 LQ1-2B07 LQ1T2A-ST2 2 Applicable body size 2 2-07 LQ1-2N07 LQ1-2B07 2-07 LQ1-2N07 LQ1-2B07 LQ1T2A-ST3 2 2-07 LQ1-2N07 LQ1-2B07 Applicable body size 2 LQ1T2A-ST4 2 Applicable body size 2 2-07 LQ1-2N07 LQ1-2B07 LQ1T3A-ST1 3 3-11 LQ1-3N11 LQ1-3B11 Applicable body

-00 AQ240F-07-07 13.7 13.7 15.4 6.2 13.7 27.3 40.7 8 10.0 15.1 6.2 1/4" 12 6 1/4" 12 40.7 AQ340F-07-00 AQ340F-07-07 16.8 20.3 13.7 16.8 7.1 52.2 33.1 20.0 13 11.8 1/4" 13.2 11 1/4" 13.2 7.1 22.2 15-12-4 1 Speed Exhaust Controller Series ASV Size: M3, M5, 1/8, 1/4, 3/8 How to Order Integration of a quick exhaust valve and an exhaust restrictor permits high-speed cylinder operation. 3 1 0 F

L4 Note) Weight (g) 5 5.5 6.5 8.5 9.5 19 22 35 38 52 86 95 Model Applicable tube O.D. d AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F-11 AS4002F-11 AS4002F-13 MIN.