When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 4 Stations, Voltage: 5 (24 VDC), Electrical Entry: L Plug Connector, Blanking Plate: B2 (2 Sets)
-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5
Load factor: ( (Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101
A1 L1 R1 U1 NDH10 U(H8) E1 MM NX Applicable bore size (mm) Applicable bore size (mm) I-02 I-03 I-04 IA-04 Part no.
Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
Size 21 31, 41 NPT Threads Port Size Accessories Applicable Body Size 20 30 40 Symbol 02 03 04 Description None Mounting Bracket Float Auto Drain (N.C.)
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
Size 21 31, 41 NPT Threads Port Size Accessories Applicable Body Size 20 30 40 Symbol 02 03 04 Description None Mounting Bracket Float Auto Drain (N.C.)
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 No. Part no.
Use a contact protection box when the wire length is 5m or longer.
PT/PF thread model I.D.4mm or more, O.o.l0mm or more, length 5m or less NPT thread model 1.0.3/16" or more, 0 .D.3/8" or more, OFluSh piping on the secondary side of AMH . length 200" or less Normally Open: ~ Open and close pipe line before operation to ensure proper connection sealing.
O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.
Choose a filtration degree of 5m or finer. A mist separator (AM) is suitable. 3. Compressed air which includes a large amount of drainage can cause malfunction of valves and other pneumatic equipment. As a countermeasure, install and air dryer or after cooler, etc. 4.
Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)