mA), Holding 0.5 VA (5 mA) 100 VAC Inrush 0.55 VA (5 mA), Holding 0.55 VA (5 mA) 110 VAC Inrush 1.0 VA (5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
(g) A B ANA1-C08~C12 ANB1-C06~C10 ANA1-C08 8 11 5 58 16 ANA1-C10 10 15 13 76 22 ANA1-C12 12 33 19 95 25 ANB1-C06 6 8 5 52 16 ANB1-C08 8 13 12 73 22 Notes: To install threaded versions screw in hand tight then wrench tighten 1/ 4 turn only.
AM150C-02 2.2 18 10.6 AMH250C-03 AMD250C-03 AME250C-03 AMF250C-03 AT6C-04 IDFB4E HAA7-06 AFF4C-03 HAW7-06 AM250C-03 3.7 30 17.7 AMH250C-03 AMD250C-03 AME250C-03 AMF250C-03 AT6C-04 IDFB6E HAA7-06 AFF4C-04 HAW7-06 AM250C-03 5.5 42 24.7 AMH350C-04 AMD350C-04 AME350C-04 AMF350C-04 AT11C-06 IDFB8E HAA15-10 AFF8C-04 HAW22-14 AM350C-04 7.5 60 35.3 AMH350C-04 AMD350C-04 AME350C-04 AMF350C-04 AT11C
/(sbar)] 12 12 12 VQC 4/5 1 4/2 (P A/B) b 0.33 0.33 0.33 Cv 3.4 3.4 3.4 2-position rubber seal VQ5 1 201 VQZ C [dm3/(sbar)] 16 16 16 4/2 5/3 (A/B EA/EB) b 0.33 0.33 0.33 SQ Cv 4.4 4.4 4.4 Note) For port size 1/2 VFS Manifold Options VFR Blanking plate assembly VVQ5000-10A-5 Individual SUP spacer VVQ5000-P-5-03 04 Individual EXH spacer VVQ5000-R-5-03 04 EXH block plate VVQ5000-16A-2 (1
Piping port Port size Series Model 3.2 4 6 8 10 12 16 4(A), 2(B) 1/4 VF5;2;-;;1-02 1(P), 5(EA), 3(EB) 1/4 4(A), 2(B) 3/8 VF5;2;-;;1-03 1(P), 5(EA), 3(EB) 3/8 4(A), 2(B) 1/4 VF5;44-;;1-02 1(P), 5(EA), 3(EB) 1/4 4(A), 2(B) 3/8 VF5;44-;;1-03 VF5000 1(P), 5(EA), 3(EB) 3/8 4(A), 2(B) 1/2 VF5;44-;;1-04 1(P), 5(EA), 3(EB) 1/2 1(P), 5(R), 3(R) 3/8 Type 20 manifold base 1(P), 5(R), 3(R) 1/2 Type 21
type> (Lead wire length) 75.4 [82.4] Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors 73.6 34.5 15.5 17.5 29.5 29.5 44.5 [1(P), 5(EA), 3(EB) port] 3/8, 1/2 96.5 L plug connector (L): M plug connector (M): DIN terminal (D, Y): 10-SY9140(R)-WO03 04 M8 connector (WO): D Y 10-SY9140(R)10-SY9140(R)-M10-SY9140(R)-L03 04 03 04 03 04
-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1000 25 15 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 1500 Effective area (mm2) Effective area (mm2) 20 10, 12 10 08 1000 15 500 10 5 500 5 0 0 0 0 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) 2 Stainless Steel Speed Controller Series ASG Construction Elbow type
-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1000 25 15 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 1500 Effective area (mm2) Effective area (mm2) 20 10, 12 10 08 1000 15 500 10 5 500 5 0 0 0 0 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) 2 Stainless Steel Speed Controller Series ASG Construction Elbow type
Nil S P W 0.5 to 4 L/min (Symbol 04) 0.50 0.49 0.50 0.48 2 to 16 L/min (Symbol 20) 1.79 1.21 1.38 1.05 5 to 40 L/min (Symbol 40) 4.57 3.11 2.42 2.04 Flow range: 0.5 to 4 L/min (symbol 04) Flow range: 2 to 16 L/min (symbol 20) Flow range: 5 to 40 L/min (symbol 40) -52No.PF-OMW0004-B Flow rate characteristics for several supply units Flow range: 0.5 to 4 L/min (symbol 04) (reference value)
8 KQR04-08 10.4 36.5 18.5 16 5.6/5.6 5/32 6.3(1/4) KQR03-07 11 36 19 16 3 4 10 KQR04-10 12.8 39.5 18.5 16 5.6/5.6 3/16 6.3(1/4) KQR05-07 12 39 22 16.5 3.5 6 4 KQR06-04 12 37.5 21.5 17 4/4 3/16 8(5/16) KQR05-09 12 38 19.5 16.5 3.5 6 8 KQR06-08 12.8 37 18.5 17 13.1/13.1 1/4 8(5/16) KQR07-09 14 41.5 23 17 4.6 6 10 KQR06-10 12.8 39.5 18 17 13.1/13.1 1/4 9.5(3/8) KQR07-11 14 40 20 17 4.6 6 12
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/
Contents Bore size (mm) Seal Kit List Description Material Note No. 20 25 32 40 50 63 80 100 MGP20-B-PS MGP25-B-PS MGP32-B-PS MGP40-B-PS MGP50-B-PS MGP63-B-PS MGP80-B-PS MGP100-B-PS @4 @5 @6 @7 #5 #6 $4 $5 Piston seal NBR Set of left nos. @4, @5, @6, @7, #5, $4, $5 Rod seal NBR Gasket A NBR Gasket B NBR Set of left nos. @4, @5, @6, @7, #5, #6, $4, $5 Set of left nos. @4, @5, @6, @7, #5, $4
Table (3) Rated Voltage Electrical Option Rated voltage Solenoid valve model (Port size) Orifice symbol (diameter) 1 (2 mm) 2 (3 mm) 3 (4.5 mm) 4 (6 mm) 5 (8 mm) 6 (10 mm) Voltage L (With light) Voltage symbol 5 6 24 VDC 12 VDC VXE21 Model VXE22 VXE23 02 (1/4) 03 (3/8) 04 (1/2) 01 (1/8) Port symbol (Port size) 02 (1/4) 03 (3/8) 04 (1/2) 02 (1/4) Table (4) Bracket Part No.
, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 200 100 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
Metric size Inch size 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 23 04 06 08 10 12 3.2 4 6 8 10 12 With One-touch fittings Stainless steel specifications (Stainless steel 303) Use 1/8" tube. Made to Order Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 Lubricant: Vaseline X12 Ex.) AS1001FG-04-X12 Ex.)
1 8 1 4 3 16 3 16 5 32 1 4 3.5 16.5 3 16 1 4 5 16 4.6 17 1 4 3 8 K 3 8 6 18.5 5 16 1 2 Applicable tubing M 7 21 1 2 3 8 Note) D: Max. diameter H KK D MS Cross: KQ2TW Applicable tubing O.D.
size Rc1/ 2 Manifold Options Individual SUP spacer VVQ5000-P-5Blank plate assembly VVQ5000-10A-5 Individual EXH spacer VVQ5000-R-5EXH blocking plate VVQ5000-16A-2 03 04 03 04 Throttle valve spacer VVQ5000-20A-5 SUP stop valve spacer VVQ5000-37A-5 SUP blocking plate VVQ5000-16A-1 Double check spacer with residual pressure release valve VVQ5000-25A-5 PUSH LOCK Direct exhaust with silencer
, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 200 400 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 100 200 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.
5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.