SMC Corporation of America
Elite Part Number Search
Search Results "SYJ3323-6LOZ-M3"

The intersection H is the amount of moisture included in the compressed air 35 ft3 (1 m3) at 102psi (0.7 MPa), and a pressure dew point 77F (25C). The amount of moisture is 0.003 oz./ft3 (3.0 g/m3). 10.

No. of output points, 16 point M3 screw Item Specifications 24 VDC, +10%, 5% External power supply For details on specifications and handling, refer to the separate technical instruction manual.

DC 5 6 24 VDC 12 VDC Made to Order Nil AC (50/60 Hz) Pilot exhaust port with piping thread (M3) specification (Refer to page 24).

IDFB4E to 15E AT 1.6 [40] IDF IDU Air Flow Capacity 2.36 [60] Model IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFA D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) IDFB IDFB A Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature

Tightening torque for round head Phillips screws for tie-rods of the regulator manifold. 0.32 0.03N.m M3 thread Square nut (M3) Square nut (M3) Note) M3 threads and square nuts are not included. End block 0.32 0.03 N.m Round head Phillips screw (with SW) (M3) 3. Tightening torque for hexagon socket set screws for DIN rail of the regulator manifold DIN rail 2.

Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A AS Series Speed Controller: Standard Type In-line Type Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.

Note 1) Sampling air flow rate: Number of particles contained in 75l of air Note 2) Actuator: 1 million cycles Solenoid valve: 2 million cycles Particle generation characteristics of CM2 Particle generation characteristics of CXSL Particle generation characteristics of CY1B 106 106 106 Particle concentration (particles/m3) Particle concentration (particles/m3) Particle concentration (particles

Applicable shaft types: S, W, Y X = Q1 = M L1 = L2 = L1 Q2 = M Q1 [mm] [mm] Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25 6.8 6.8 6.8 M10 x 1.5 8.5 8.5 M12 x 1.75 10.3 10.3 Rc1/8 8 8 Rc1/4 11 Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25 6.8 6.8 6.8 M10 x 1.5 8.5 8.5 M12 x 1.75 10.3 10.3 Rc1/8 8 8 Rc1/4 11 [

It is calculated using the following formula: 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow rate characteristics are shown in Graph (2).

It is calculated using the following formula: 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow rate characteristics are shown in Graph (2).

Mount the sensor head using two M3 screws (not supplied with the product). M3 screws M3 screws M3 screws Due to the construction of the sensor, the sensor head housing is shared with GND. Install and supply power with great caution to avoid short-circuit with the +24 V power supply. The detection port is opened to detect static electricity.

Size Ejector System Vacuum Pump System Port Metric Inch Metric Inch PV 6 1/4 6 1/4 V 6, 8 1/4, 5/16 6, 8 1/4, 5/16 EXH (Port exhaust) 8 5/16 PE EXH Common Port open to atmosphere Note 1) PS 4 5/32 PD Note 2) M3 M3 : Not applicable Note 1) Piping for PE port is available as an option (M3). Refer to page 11. Note 2) A model with PD port (M3) is available as an option. Refer to page 11.

To secure the emitter cartridge with a screw, use an M3 x 0.5 12mm cross recessed round head screw (The screw needs to be prepared by the user). M3 screw recommended tightening torque is 0.25 to 0.35 Nm. Install the ionizer so that the emitter cartridge can be removed for maintenance and replacement of the emitters.

Max. load mass Review M1, M2, M3. M max is the allowable moment. 2 = M/M max 2. Static moment Review Me1, Me3. Me max is the allowable moment. 3 = Me/Me max 3.

Max. load mass 2 = M/Mmax Review M1, M2, M3 Mmax is the allowable moment 2. Static moment 3 = Me/Memax Review Me1, Me3 Memax is the allowable moment 3.

Max. load mass 2 = M/Mmax Review M1, M2, M3 Mmax is the allowable moment 2. Static moment 3 = Me/Memax Review Me1, Me3 Memax is the allowable moment 3.

Max. load mass 2 = M/Mmax Review M1, M2, M3 Mmax is the allowable moment 2. Static moment 3 = Me/Memax Review Me1, Me3 Memax is the allowable moment 3.

Basic style Width across flats 3.5 23 9 4.5 4.5 MXH MXU 6.5 3.5 2 x M3 x 0.5 (Port size) MXS 2 x M3 x 0.5 MXQ (Port size for axial piping type MTS8-P) 0.2 2 x M3 x 0.5, effective length 5 9 5 MXF +0.035 +0.025 4 MXW 22 12 16 MXJ M2.5 x 0.45 12 41 + Stroke MXP 53 + Stroke 9 15 MXY MTS 0.2 9 4 x M3 x 0.5, effective length 5 10 15 Rod end male thread Width across flats 3.5 +0.035 +0.025 4 M3

. : MH-G04 (30g) 664 Series MHY2 180 Angular Style Air Gripper Cam Style Dimensions MHY2-10D Pin hole positioning 30 9 9 2 x M3 x 0.5 thread depth 4 4 (Thread for mounting attachment) 4 x M3 x 0.5 through (Mounting thread) 3H9+ 0.025 0 depth 3 6 0.005 0.025 4 4 x M3 x 0.5 thread depth 6 3 6 (Mounting thread) 2 x 3.4 through 2 x M3 x 0.5 depth 6 12 (Mounting hole) (Mounting thread) (Limted