MTS
Note 5) When the option, high pressure pump mounted, is selected, the weight increases by 4 kg for -10 type and 6 kg for -20 type.
(mm) (Kg) 50 1.70 / 63 2.78 80 4.96 4 - RS1H 1. mA 2. V(m/min) (Kg) 3.
Please refer below for calculation of kinetic energy. 2 ) ( 2 1 O I I E E: Kinetic energy [ J ] I: Moment of inertia of load [ 2 m kg ] Io: Moment of inertia of load [ 2 m kg ] : Angular speed [ s rad ] The following table shows moment of inertia of table. Table 6.
(Kg) 100 7.3 8.3 Type of actuation solenoid closed center exhaust solenoid center center Size single single pressure Table (6) Additional mass (kg) 50 to 100 0.4 0.5 0.6 0.6 0.6 Additional mass Size With auto switches( 2 pcs) Foot bracket 50 0.2 0.3 63 0.4 0.5 80 0.6 0.9 100 0.9 1.2 Effective torque Table (7) Effective torque table (Nm) Operating pressure (MPa) Size 0.1 0.2 0.3 0.4 0.5 0.6
Weight9 kg 35 For option T42 *1 Use the product in conditions where freezing will not occur.
Product weight Model LEJS100 Stroke [mm] 200 300 400 500 600 800 1000 1200 1500 Product weight [kg] 20.4 22.5 24.6 26.7 28.8 33.0 37.1 41.3 47.6 1.0 Additional weight with lock [kg] -5- 1.2 Motorless 1.2.1 How to order L E J S 100 N B 500 T X400 Motor type Stroke [mm] Lead [mm] N Motorless 200 200 H 50 to to A 25 1500 1500 B 10 *Refer to the applicable stroke table.
Note2) In the case of horizontal operation, be sure m : Weight of cylinders moving parts (kg) that the load weight does not exceed the allowable lateral load found v: Maximum speed (m/s) va : Average speed (m/s) 3 9. Precautions on Selection 1) Confirm the specifications. Products represented in this manual are designed only for use in compressed air systems.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
EK: Kinetic energy of load (J) m: Load weight (kg) (Weight of load + Weight of moving parts) : Piston speed (m/s) (Average speed x 1.2) 2. The piston speed will exceed the average speed immediately before locking. To determine the piston speed for the purpose of obtaining the kinetic energy of load, use 1.2 times the average speed as a guide. 3.
ED301S-X10V Weight 0.06 kg Case/Cover A2017 (Clear anodized) Main material Seal Fluororubber (FKM) Element Part No. Element PTFE membrane Dimensions are identical to the standard models. For details, refer to page 305. Note) Based on SMCs measuring conditions.
weight kg Load weight kg 80 80 B W 63 63 10 10 50 50 B: Retraction locking F: Extension locking 5 5 40 40 32 32 25 25 1 0.5MPa 0.4MPa 0.5MPa 0.4MPa 1 20 20 0.5 0.5 100 500 100 500 Maximum speed mm/s Maximum speed mm/s 29 Series CLQ Specific Product Precautions 2 Be sure to read before handling.
Dynamic moment Va Calculation Example m Operating conditions Cylinder: CYV32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of the arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/m max = 1/5 = 0.20 L2 Review m. L1 2.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
Weight of 2 attachments (m2): 0.05 kg Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Load weight m1 (kg) Vertical mounting Horizontal mounting Weight of 2 attachments m2 (kg) Rotation time 2 Confirm that it is within the adjustable rotation time range. 0.2 s/90
Pilot Pressure 1 ~ 5 Bar Weight 0.85 kg 3.8 kg 7.5 kg 3.8 kg 7.5 kg *Pressure IN=OUT=10 Bar **Pressure IN=OUT=5 Bar H O W T O O R D E R (N)VBA B O O S T E R R E G U L AT O R (N)VBA 0 ACCESSORIES (N)VBA BOOSTER REGULATOR S P A R E S K I T S KT-VBA2100-P (N)VBA2000 Series KT-VBA4100-P (N)VBA4000 Series Japanese N North American O P T I O N G Pressure Gauge N Silencer B O D Y S I Z E 1 14
Load Weight W 20 Maximum Load Weight MXW25 17 (kg) W 15 Maximum load weight (kg) 12 MXW20 W Model 10 MXW16 MXW8 1.8 7 6 MXW12 4 5 4 MXW12 MXW16 7 3 2.5 MXW20 11 2 MXW8 1.7 MXW25 17 1.5 W W 1.2 Note) No need to consider this load factor in the case of using perpendicularly in a vertical position. 1 50 100 200 300 500 Piston speed (mm/s) Graph (1) Mp/Mep (Pitch moment) My/Mey (Yaw moment) Mr
Dynamic moment Va Calculation example m Operating conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2.
Weight 1.2 kg Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size 04 06 10 1/2 3/4 1 JIS Symbol Dimensions PA 14 R(3) P(1) (2)A 54 73.5 X 68 87.4 MAX. 2 132.6 (External pilot port) Rc 1/8 (Pilot port) Rc 1/8 (Pilot EXH port) Rc 1/8 62.3 PA (Mounting hole) 2-